ABB M3JP Series (Shanghai) High-Efficiency Flameproof Three-Phase Induction Motors for Hazardous Areas

ABB M3JP Series (Shanghai) High-Efficiency Flameproof Three-Phase Induction Motors for Hazardous Areas

ABB M3JP Series (Shanghai) High-Efficiency Flameproof Three-Phase Induction Motors for Hazardous Areas

The ABB M3JP series are low-voltage cast-iron high-performance flameproof three-phase induction motors for hazardous areas manufactured by ABB Shanghai Electric Motors Co., Ltd. Developed on ABB’s global unified design platform with advanced modular ADEPT design, they represent ABB’s flagship flameproof low-voltage motor range.

Designed specifically for explosive gas atmospheres in Zone 1 and Zone 2, these motors feature ultra-high efficiency (IE3 as standard, IE4 available for selected models) and exceptional reliability, widely used in petrochemical, coal, farmaceutic, metallurgical and other industries.

  1. Model Naming Convention
PartSensExemplu
M3JPSeries identification: High-efficiency flameproof three-phase induction motor for hazardous areasM3JP
Frame SizeCenter height (mm) and frame length80MA, 90LA, 100LA, 112MA, 132SM, 160MA, 180LA, 200LA, 225SM, 250M, 280S, 315S, 315M, 355S, 355M
MontareInternational standard mounting configurationsM=B3 (foot-mounted)
A=B5 (flange-mounted)
B=B35 (foot + flange-mounted)
E=B14 (small flange-mounted)
PoloniiNumărul de poli, determining synchronous speed2=2900rpm (50Hz)
4=1450rpm (50Hz)
6=970rpm (50Hz)
8=730rpm (50Hz)
Special OptionsSpecial designationsG=Special voltage/frequency
L=Low noise
W=Outdoor type
TH=Humid tropical type
CT4=Gas group IIC

Complete model example: M3JP160MA4-CT4

Descriere: M3JP series, 160mm frame, B5 flange mounting, 4 stâlpi (1450rpm), gas group IIC, temperature class T4 flameproof motor.

  1. Key Technical Specifications
ArticolStandardOpțional
Efficiency ClassIE3 (High Efficiency)IE4 (Premium Efficiency)
Flameproof RatingEx db IIB T4 Gb (standard)Ex db IIC T4/T5/T6 Gb
Ex db I Mb (for coal mines)
Ingress ProtectionIP55IP56 / IP65 (enhanced dust & water protection)
Insulation ClassClass F (temperature rise evaluated as Class B)Class H
Metoda de răcireIC411 (self-ventilated)IC416 (separately driven fan cooling, suitable for VFD operation)
Tensiune nominală380V / 400V (50Hz)220V/380V, 415V, 440V, 660V, etc.
Frecvența nominală50Hz60Hz
Gama de putere0.25kW ~ 950kWCustom power
Pole Range2P, 4P, 6P, 8P10P, 12P (custom)
ConnectionStar/Delta (Star ≤3kW, Delta ≥4kW)Special connection
Mounting DimensionsIEC standardCustom dimensions
Weight RangeAproximativ. 10kg (smallest) ~ 1500kg (largest)Depending on configuration
  1. Flameproof Characteristics & Certificari

4.1 Flameproof Principle

Featuring Ex db flameproof construction, safety is ensured by two protective measures:

Flameproof enclosure (Ex d): Withstands internal explosion pressure and prevents flame propagation to the external hazardous atmosphere.

Surface temperature limitation (Ex b): Maximum surface temperature of all motor parts does not exceed the limit defined by temperature class (T4=135°C, T5=100°C, T6=85°C).

4.2 Applicable Hazardous Environments

MediuApplicable ZoneGas GroupTemperature Class
Explosive gas atmosphereZone 1 (explosive mixture likely under normal operation)IIB (standard)T4 (standard)
Zone 2 (explosive mixture unlikely under normal operation, only in fault conditions)IIC (opțional, for more hazardous gases including H₂, acetylene)T5/T6 (opțional)
Underground coal mineCategory I (minerit)eu (methane)T1–T4

4.3 Certificari

Intern: CQST (China Quality Supervision and Testing Center for Explosion-Proof Products)

Internaţional: IECEx, ATEX, UL, CSA, etc.

Classification Society: ABS, DNV, LR, etc. (opțional)

  1. Complete Model List (Grouped by Frame Size)

5.1 Small Frames (80–132mm)

FramePoloniiGama de putere (kW)Typical Models
80MA2,4,60.25–0.75M3JP80MA2 (0.75kW,2P)
M3JP80MA4 (0.55kW,4P)
M3JP80MA6 (0.25kW,6P)
90LA2,4,61.1–1.5M3JP90LA2 (1.5kW,2P)
M3JP90LA4 (1.1kW,4P)
M3JP90LA6 (0.75kW,6P)
100LA2,4,62.2–3.0M3JP100LA2 (3.0kW,2P)
M3JP100LA4 (2.2kW,4P)
M3JP100LA6 (1.5kW,6P)
112MA2,4,64.0–5.5M3JP112MA2 (5.5kW,2P)
M3JP112MA4 (4.0kW,4P)
M3JP112MA6 (3.0kW,6P)
132SM2,4,6,85.5–7.5M3JP132SM2 (7.5kW,2P)
M3JP132SM4 (5.5kW,4P)
M3JP132SM6 (4.0kW,6P)
M3JP132SM8 (3.0kW,8P)

5.2 Medium Frames (160–250mm)

FramePoloniiGama de putere (kW)Typical Models
160MA2,4,6,811–15M3JP160MA2 (15kW,2P)
M3JP160MA4 (11kW,4P)
M3JP160MA6 (7.5kW,6P)
M3JP160MA8 (5.5kW,8P)
180LA2,4,6,818.5–22M3JP180LA2 (22kW,2P)
M3JP180LA4 (18.5kW,4P)
M3JP180LA6 (15kW,6P)
M3JP180LA8 (11kW,8P)
200LA2,4,6,830–37M3JP200LA2 (37kW,2P)
M3JP200LA4 (30kW,4P)
M3JP200LA6 (18.5kW,6P)
M3JP200LA8 (15kW,8P)
225SM2,4,6,845–55M3JP225SM2 (55kW,2P)
M3JP225SM4 (45kW,4P)
M3JP225SM6 (30kW,6P)
M3JP225SM8 (22kW,8P)
250M2,4,6,875–90M3JP250M2 (90kW,2P)
M3JP250M4 (75kW,4P)
M3JP250M6 (45kW,6P)
M3JP250M8 (37kW,8P)

5.3 Large Frames (280–355mm)

FramePoloniiGama de putere (kW)Typical Models
280S2,4,6,8110–132M3JP280S2 (132kW,2P)
M3JP280S4 (110kW,4P)
M3JP280S6 (75kW,6P)
M3JP280S8 (55kW,8P)
315S2,4,6,8160–200M3JP315S2 (200kW,2P)
M3JP315S4 (160kW,4P)
M3JP315S6 (110kW,6P)
M3JP315S8 (75kW,8P)
315M2,4,6,8220–250M3JP315M2 (250kW,2P)
M3JP315M4 (220kW,4P)
M3JP315M6 (132kW,6P)
M3JP315M8 (90kW,8P)
355S2,4,6,8280–315M3JP355S2 (315kW,2P)
M3JP355S4 (280kW,4P)
M3JP355S6 (160kW,6P)
M3JP355S8 (110kW,8P)
355M2,4,6,8355–400M3JP355M2 (400kW,2P)
M3JP355M4 (355kW,4P)
M3JP355M6 (200kW,6P)
M3JP355M8 (132kW,8P)
  1. Cross-Reference Order Codes with Major Global Brands

Below are equivalent order codes for ABB M3JP series flameproof motors against other leading brands, matched by power, stâlpi, flameproof rating and mounting:

ABB M3JP ModelSiemensSchneiderEatonDomestic Alternative (Nanyang Explosion Proof)
M3JP90LA4-1.1kW1LG4090-4AA70-ExATV212HD11N4-ExD2N090L4-ExYBX3-90L-4-1.1kW
M3JP132SM4-5.5kW1LG4132-4AA70-ExATV212HD55N4-ExD2N132S4-ExYBX3-132S-4-5.5kW
M3JP160MA4-11kW1LG4160-4AA70-ExATV212HD11N4-ExD2N160M4-ExYBX3-160M-4-11kW
M3JP180LA4-18.5kW1LG4180-4AA70-ExATV212HD18N4-ExD2N180L4-ExYBX3-180L-4-18.5kW
M3JP200LA4-30kW1LG4200-4AA70-ExATV212HD30N4-ExD2N200L4-ExYBX3-200L-4-30kW
M3JP225SM4-45kW1LG4225-4AA70-ExATV212HD45N4-ExD2N225S4-ExYBX3-225S-4-45kW
M3JP250M4-75kW1LG4250-4AA70-ExATV212HD75N4-ExD2N250M4-ExYBX3-250M-4-75kW
M3JP315S4-160kW1LG4315-4AA70-ExATV212HD16N4-ExD2N315S4-ExYBX3-315S-4-160kW
  1. Ghid de selecție & Replacement Recommendations
  2. Flameproof rating matching: Select according to gas group (IIB/IIC) and temperature class (T4/T5/T6) of the hazardous area. IIC motors can replace IIB, but not vice versa.
  3. Efficiency selection: IE3 standard for general applications; IE4 premium efficiency for high energy-saving requirements.
  4. Cooling method: IC416 with separate fan recommended for VFD applications to avoid overheating at low speeds.
  5. Mounting dimensions: Strictly comply with IEC standard dimensions to ensure compatibility.
  6. Cerințe de certificare: Confirm required certifications for critical applications (CQST for domestic projects, IECEx/ATEX for international projects).
  7. Replacement notes:

Ensure replacement power ≥ original and flameproof rating ≥ original.

Verify mechanical dimensions: shaft height, shaft diameter, keyway size.

Confirm terminal box position and cable entry size match the original motor.

For special environments (marine, outdoor, humid tropical), select correspondingly configured models.

  1. Ordering & Packaging Information

Official order code: Same as model number, de ex., M3JP160MA4, M3JP225SM4-CT4.

Standard packaging: Plywood case, single or multiple units per package.

Origine: ABB Shanghai Electric Motors Co., Ltd. (Adresa: 88 Tianning Road, Minhang District, Shanghai)

Lead time: 2–4 weeks for standard models; 4–8 weeks for custom models.

Accessories: Motor body, terminal box cover, foundation bolts, certificate of conformity, copy of explosion-proof certificate.