Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

Parametrii tehnici completi ai Siemens 3WL1116/3WL1216 1600A ETU45B-G-LCD-3P - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

ŞtiriȘtiri comerciale

Parametrii tehnici completi ai Siemens 3WL1116/3WL1216 1600A ETU45B-G-LCD-3P

Complete Technical Parameters of Siemens 3WL1116/3WL1216 1600A ETU45B-G-LCD-3P

The parameters cover dimensions including basic electrical characteristics, capacitatea de rupere, trip unit, mechanical & environmental performance, communication and installation, facilitating engineering selection and system matching.

  1. Basic Electrical Parameters
Element de parametruSpecification ValueRemarks
Seria de produseSiemens SENTRON 3WLÎntrerupător de aer (ACB)
Frame Size3WL1116 (Frame I) / 3WL1216 (Frame II)3WL1116: Standard breaking capacity; 3WL1216: High breaking capacity
Curent nominal (În)1600OFrame size current 1600A, setting range 0.4–1In
Numărul de pol3PThree-pole, 3-phase main circuit
Rated Operational Voltage (Ue)690V și50/60Hz, compliant with IEC 60947-2
Tensiune nominală de izolație (Ui)1000V șiBenchmark value for insulation withstand capability
Rated Impulse Withstand Voltage (Uimp)12kVCompliant with IEC 60947-1
Rated Short-time Withstand Current (Icw)Frame I: 66kA/1s; Frame II: 80kA/1sEnsures short-time thermal stability at 500V
Capacitate de rupere (Icu)Frame I: 55/66cel; Frame II: 80/100celUltimate breaking capacity at 500V; Frame II offers higher breaking capacity
  1. Parameters of ETU45B-G-LCD Electronic Trip Unit
Function ModuleSpecification ValueDescriere
Protection TypeLSIG (L: Overload/Long-time Delay; S: Short-circuit/Short-time Delay; eu: Instantaneous Short-circuit; G: Ground Fault)Complete power distribution protection configuration
Protecție la suprasarcină (L)Characteristic Curve: I²t/I⁴t selectable; Setting Range: 0.4–1InI⁴t characteristic improves selectivity with downstream devices
Short-time Delay Short-circuit Protection (S)Setting Current: 2–10In; Time Delay: 0.1–0.4sAdjustable inverse/definite time delay to prevent selective tripping
Instantaneous Short-circuit Protection (eu)Setting Current: 2–10InRapid short-circuit current interruption without time delay
Protecție împotriva defecțiunii la pământ (G)Setting Current: 0.2–0.8In; Time Delay: 0.1–2sDetects ground faults to avoid equipment damage
Display & OperationLCD screen, rotary coding switchReal-time display of current, trip cause and fault records
Reset MethodManual/Auto selectableQuick power supply recovery after fault clearance

III. Mechanical & Environmental Parameters

Element de parametruSpecification ValueRemarks
Viața mecanică150,000 operațiuniNo-load operation, compliant with IEC 60947-2
Viața electrică10,000 operațiuni (AC-3, at rated current)On-load breaking life, related to operating frequency
Operating MechanismSpring-loaded energy storage type (manual/electric optional)Electric mechanism suitable for remote control
Contacte auxiliareStandard: 2NU+2NC, expandable to 4NO+4NCStatus feedback and control circuit interlocking
Temperatura ambiantă-25℃~+70℃ (operating); -40℃~+85℃ (storage)Wide temperature range for industrial applications
Clasa de protectieIP30 (body); IP40 (with protective cover)Prevents solid foreign object intrusion
Altitudine≤2000m (derating required above 2000m)Rated current derating by 1% for every 100m altitude increase
Metoda de montareFixed type/Drawout typeDrawout type enables maintenance without power outage
  1. Communication & Measurement Parameters
FuncţieCaietul de sarciniInterface/Protocol
Communication ModuleCOM15 (PROFIBUS DP) / COM16 (MODBUS RTU)Opțional, supports data upload to monitoring system
Measurement AccuracyActual: ±1%; Voltaj: ±1.5%; Putere: ±2%Compatible with Plus measurement function for energy management
Data Logging100 fault records (trip type, time, current value)Fault tracing and system diagnosis
Remote ControlSupports remote opening/closing and parameter settingRealized by electric mechanism + communication module
  1. Instalare & Dimension Parameters
Mounting TypeLăţime (W)Înălţime (H)Adâncime (D)Greutate
3WL1116 Fixed Type320mm434mm291mmApprox. 45kg
3WL1116 Drawout Type320mm434mmApprox. 450mmApprox. 55kg
3WL1216 Fixed Type460mm434mm291mmApprox. 56kg
3WL1216 Drawout Type460mm434mmApprox. 450mmApprox. 65kg
Mounting Mode35mm DIN rail/screw mountingFrame I width: 320mm; Frame II width: 460mm; Unified height: 434mm
  1. Key Selection & Application Tips
  2. Breaking Capacity Matching: Select frame size based on the system’s maximum short-circuit current. Frame I is suitable for scenarios ≤66kA, while Frame II is for ≤100kA. O 20% margin is recommended.
  3. Trip Unit Setting: Enable LSIG protection for motor loads, with the ground fault setting recommended at 0.3–0.5In. LSI protection is sufficient for power distribution loads.
  4. Communication Compatibility: Select COM15/COM16 module for remote monitoring, ensuring protocol compatibility with PLC/SCADA systems (PROFIBUS/MODBUS).
  5. Installation Space: The drawout type occupies approximately 160mm more depth than the fixed type. Reserve sufficient operation and maintenance space during cabinet design.
  6. Replacement & Upgrade: The 3WL series has been upgraded to the 3WA series (de ex., 3WA1116-3EG45-4GA4), featuring compatible dimensions and protection functions, plus added Ethernet communication and intelligent diagnosis.

 

 

VII. Compliance & Certification

Compliant Standards: GB 14048.2, IEC 60947-2, ÎN 60947-2

Certificari: CE, UL, CSA (pentru unele modele), meeting compliance requirements for global industrial applications

Prev:

Următorul:

Lasă un răspuns

Lăsaţi un mesaj