Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

ABB-MCCB-XT6S-3P-800 - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

întrerupător de circuit/

ABB-MCCB-XT6S-3P-800

Interpretarea Codului Modelului (ABB SACE Tmax XT Series) Code Segment Description Details ABB‑MCCB Brand & Type ABB Molded Case Circuit Breaker XT6S Series & Rating XT6 series (800A frame), S = standard breaking capacity (22cel). Also available: L = high (50cel), H = ultra‑high (65cel) 3P Number of Poles 3‑pole, for three‑phase circuit protection 800 ...

  • Detalii despre produs

Interpretarea Codului Modelului (ABB SACE Tmax XT Series)

Code SegmentDescriereDetails
ABB‑MCCBMarca & TipABB Molded Case Circuit Breaker
XT6SSerie & RatingXT6 series (800A frame), S = standard breaking capacity (22cel). Also available: L = high (50cel), H = ultra‑high (65cel)
3PNumărul de poli3‑pole, for three‑phase circuit protection
800Curent nominalRated operational current 800A; adjustable range varies by trip unit type
Complete Model Examples1SDA100740R1XT6S 800 TMA 800‑8000 3p F F (Thermal‑magnetic trip)XT6S 800 EkipDip LS/I 800A 3p F F (Electronic trip)
1SDA100741R1
  1. Parametrii tehnici de bază (XT6S 800A 3P Standard Configuration)
Categoria parametrilorCaietul de sarciniObservații
Cadrul curent800OSuitable for rated current settings from 630A to 800A
Rated Operational Voltage690V și, 750În DCComplies with IEC 60947‑2
Tensiune nominală de izolație1000VEnsures safe insulation performance
Tensiune nominală de rezistență la impuls8kVSurge voltage immunity
Capacitate de rupereIcu = 22kA @ 400VType S standard breaking capacity, for general industrial environments
Ics = 11kA @ 400V (50% Icu)
Tip de montareFixed (F) / Plug‑in (P) / Drawer (D)Standard: Fixed (F); other types available on request
Connection TypeFront connection (F) / Rear connection (R)Standard: Front connection (F), easy for panel installation and maintenance
Ingress ProtectionIP30Complies with EN 60529; dust‑protected, finger‑protected
Temperatura de operare-25℃ ~ +70℃Standard range; derating required above 40℃
  1. Trip Unit Types & Funcții de protecție (Key Configuration Differences)
  2. Thermal-Magnetic Trip Unit (TMA)

Funcții de protecție: Protectie la suprasarcina (L) + instantaneous short-circuit protection (eu)

Current Settings: Overload 0.8-1.0×In (640-800O), instantaneous 4000-8000A (5-10×In)

Application: Simple power distribution systems, no complex settings required, rentabil

Complete Model: XT6S 800 TMA 800-8000 3p F F (1SDA100740R1)

  1. Electronic Trip Unit (EkipDip LS/I)

Funcții de protecție: Adjustable overload (L) + short-time delay short-circuit (S) + instantaneous short-circuit (eu) protecţie

Current Settings: L = 0.4-1.0×In (320-800O), S = 1.0-10×In (800-8000O), I = 5-10×In (4000-8000O)

Additional Features: Supports remote control, fault indication, communication expansion (with Ekip Com module)

Application: Complex power distribution systems requiring precise protection settings; suitable for motors and transformers

Complete Model: XT6S 800 EkipDip LS/I 800A 3p F F (1SDA100741R1)

  1. Key Features & Avantaje (XT6S Series)
  2. Design modular: Interchangeable thermal-magnetic / electronic trip units; 3 breaking capacity levels for flexible system matching
  3. Installation Flexibility: Fixed, plug-in, and drawer mounting; front/rear connection options to save panel space
  4. Siguranţă & Fiabilitate: UL 100% rated, IEC certified; mechanical life 20,000 operațiuni, electrical life 5,000 operațiuni
  5. Smart Expansion: Electronic trip versions support Ekip Com modules for Profinet, EtherNet/IP and other protocols
  6. Eco-Design: Conform RoHS, free of hazardous substances, high recyclability
  7. Easy Maintenance: Modular components enable quick replacement and reduced downtime
  8. Complete Model Matrix (XT6S 800A 3P Full Configurations)
Tip de călătorieCapacitate de rupereComplete Model (Order Code)
Thermal‑Magnetic (TMA)S (22cel)1SDA100740R1XT6S 800 TMA 800‑8000 3p F F
Thermal‑Magnetic (TMA)S (22cel)1SDA102846R1XT6S 800 TMA In=800A 3p F F UL (UL certified)
Electronic (EkipDip)S (22cel)1SDA100741R1XT6S 800 EkipDip LS/I 800A 3p F F
Electronic (EkipM)S (22cel)1SDA100747R1XT6S 800 EkipM Dip I 800A 3p F F (Motor protection)
Electronic (EkipG)S (22cel)1SDA102847R1XT6S 800 EkipG Dip LS/I 800A 3p F F (Advanced protection)
  1. Applications & Recomandări de selecție

Aplicații tipice

Main power distribution in industrial plants (secondary protection for 630-800kW transformers)

Large motor control centers (MCC), protecting 75-90kW three-phase motors (parallel groups)

UPS output protection in data centers

Main distribution boards in commercial buildings

Inverter output protection in PV power stations

Selection Guidelines

  1. Breaking Capacity Matching: Select S/L/H versions based on system short-circuit current
  2. Trip Selection: Termo-magnetic (TMA) for simple distribution; electronic (Ekip) for complex systems
  3. Tip de montare: Fixed for new installations; plug-in/drawer for frequent maintenance
  4. Rated Current Setting: Match total load current; recommended 1.1-1.2× load current
  5. Adaptarea mediului: No derating at -10℃~+40℃; derate 1% per °C above 40℃
  6. Modele alternative & Brand Comparison (Market Reference 2026)

ABB Same-Series Alternatives

Alternative ModelMain DifferenceApplication
XT6L 800 3PHigher breaking capacity 50kASystems with high short‑circuit current
XT6H 800 3PUltra‑high breaking capacity 65kAIndustrial busbars, Isc > 50cel
XT6S 630 3PSmaller frame current 630ALoad current ≤ 630A

Other Brand Alternatives

MarcaAlternative ModelEquivalent Breaking CapacityPrice Comparison
SchneiderNSX630N‑800A 3P25cel (similar to S type)5–8% lower than ABB
Siemens3VA6880‑6EL32‑0AA025cel (similar to S type)Comparable to ABB, richer smart functions
EatonZM800M3‑V080025cel (similar to S type)3–5% lower than ABB
ChintNM1‑800S/330025cel (similar to S type)30–40% lower than ABB, cost‑effective
  1. 2026 Market Price Reference (RMB, 13% VAT included)
ConfigurationPremier Distributor PriceGeneral Distributor PriceBulk Price (≥5 units)Observații
Thermal‑Magnetic (TMA)18,000–22,00016,000–20,00015,000–18,0001SDA100740R1
Electronic (EkipDip)22,000–26,00020,000–24,00019,000–22,0001SDA100741R1
Electronic (EkipM)24,000–28,00022,000–26,00021,000–24,0001SDA100747R1 (Motor protection)
Price Factors• Channel: Authorized distributors offer stable pricing; unauthorized channels 10–15% cheaper but no warranty
• Lead time: In stock +3–5%; 4–6 week lead time at better prices
• Services: Installation support +500–1000 RMB; 3‑year extended warranty +8–10%
  1. Instalare & Maintenance Notes
  2. Mediul de instalare

Temperatura de functionare: -10℃ ~ +40℃ (derate 1% per °C above 40℃)

Relative humidity: ≤95%, necondens

Altitudine: ≤2000m (derate above 2000m)

  1. Specificații de cablare

Conductor size: ≥185mm² copper cable for sufficient current carrying capacity

Torque requirement: Main terminal bolt torque 70Nm for reliable connection

  1. Maintenance Intervals

Routine inspection: Once monthly, check appearance and tightness

Periodic maintenance: Once yearly, clean, test trip functions, verify ON/OFF performance

  1. Selection Summary
  2. Load Evaluation: Select 800A rated current based on total three-phase current, within frame limit
  3. Short-Circuit Analysis: Calculate system short-circuit current to choose S/L/H breaking capacity
  4. Cerințe de protecție: Thermal-magnetic for basic distribution; electronic for precise protection and monitoring
  5. Installation Conditions: Choose mounting/connection based on panel space and maintenance needs
  6. Budget Consideration: Balance cost and reliability; electronic trip units recommended for critical circuits

ABB MCCB Model List & Order Codes

  1. Overview of ABB MCCB Series

ABB molded case circuit breakers mainly include two series: Tmax XT Series (high-end industrial, SACE Tmax XT1-XT7) and Formula Series (economic, Formula A1-A3), covering 16A-1600A for various applications.

  1. Model Naming Rules (Tmax XT Series Example)
PositionCodeDescriereOptions
1XT[1–7]Serie & Frame SizeXT1(160O), XT2(160O), XT3(250O), XT4(250O), XT5(630O), XT6(1000O), XT7(1600O)
2C/N/L/H/MBreaking Capacity ClassC=15kA, N=25kA, L=36/50kA, H=65kA, M=100kA
3NumberCadrul curent160/250/630/800/1000/1200/1600O
4TMD/TMA/Ekip…Tip de călătorieTMD = Thermal‑magnetic (distribution)
TMA = Thermal‑magnetic (motor)
EkipDip = Basic electronic
EkipC = Advanced electronic
5Number/RangeCurent nominal / Setting Rangee.g. 800‑8000 (thermal‑magnetic), 800O (electronic)
63P/4PPoles3P = Three‑phase, 4P = Three‑phase + N
7F/P/DMountingF=Fixed, P=Plug‑in, D=Drawer
8F/RConnectionF=Front, R=Rear
91SDA…R1Official Order CodeABB standard order number
  1. Tmax XT Series (SACE Tmax XT1-XT7) Model List & Order Codes
  2. XT1 Series (Frame 160A, 16-160A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
XT1C 160 TMD R16‑160 FF 3P1SDA067393R115celThermal‑magnetic (dist)16‑160A3PFixed/Front
XT1N 160 TMD R100 FF 4P1SDA067461R125celThermal‑magnetic (dist)100O4PFixed/Front
XT1H 160 TMA R125‑1250 FF 3P1SDA067462R165celThermal‑magnetic (motor)125O3PFixed/Front
XT1L 160 EkipDip LS/I R160 FF 3P1SDA067463R150celElectronic160O3PFixed/Front
  1. XT2 Series (Frame 160A, Premium)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
XT2N 160 TMD R63 FF 3P1SDA100730R125celThermal‑magnetic (dist)63O3PFixed/Front
XT2L 160 EkipC LSIG R100 FF 3P1015286950celAdvanced Electronic100O3PFixed/Front
XT2H 160 EkipM I R125 FF 3P1SDA100735R165celMotor Electronic125O3PFixed/Front
XT2N 160 TMA R160‑1600 FF 4P1SDA100736R125celThermal‑magnetic (motor)160O4PFixed/Front
  1. XT3 Series (Frame 250A, 16-250A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
XT3N 250 TMD R200 FF 3P1SDA100737R125celThermal‑magnetic (dist)200O3PFixed/Front
XT3L 250 EkipDip LS/I R250 FF 3P1SDA100738R150celBasic Electronic250O3PFixed/Front
XT3H 250 TMA R225‑2250 FF 3P1SDA100739R165celThermal‑magnetic (motor)225O3PFixed/Front
  1. XT4 Series (Frame 250A, Premium)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
XT4N 250 TMD R160 FF 3P1SDA100740R125celThermal‑magnetic (dist)160O3PFixed/Front
XT4L 250 EkipC LSIG R200 FF 3P1015303750celAdvanced Electronic200O3PFixed/Front
XT4H 250 EkipM I R250 FF 4P1SDA100742R165celMotor Electronic250O4PFixed/Front
  1. XT5 Series (Frame 630A, 250-630A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
XT5N 630 TMD R630‑6300 FF 3P1SDA100743R125celThermal‑magnetic (dist)630O3PFixed/Front
XT5L 630 EkipDip LS/I R630 FF 3P1SDA100744R150celBasic Electronic630O3PFixed/Front
XT5H 630 EkipC LSIG R500 FF 3P1SDA100745R165celAdvanced Electronic500O3PFixed/Front
  1. XT6 Series (Frame 800/1000A, 630-1000A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
XT6S 800 TMA 800‑8000 FF 3P1SDA100740R122celThermal‑magnetic (motor)800O3PFixed/Front
XT6S 800 EkipDip LS/I 800A FF 3P1SDA100741R122celBasic Electronic800O3PFixed/Front
XT6L 1000 TMD 1000‑10000 FF 3P1SDA100746R150celThermal‑magnetic (dist)1000O3PFixed/Front
  1. XT7 Series (Frame 1200/1600A, 1000-1600A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
XT7M 1200 EkipC LSIG 1200A FF 3P1SDA100748R1100celAdvanced Electronic1200O3PFixed/Front
XT7M 1600 TMD 1600‑16000 FF 3P1SDA100749R1100celThermal‑magnetic (dist)1600O3PFixed/Front
  1. Formula Series (Economic, A1-A3) Model List & Order Codes
  2. A1 Series (Frame 125A, 16-125A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
A1N125 TMF125/1250 FF 3P1011644825celThermal‑magnetic (dist)125O3PFixed/Front
A1C125 TMF63/630 FF 4P1011644915celThermal‑magnetic (dist)63O4PFixed/Front
  1. A2 Series (Frame 250A, 16-250A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
A2N250 TMF250/2500 FF 3P1011645025celThermal‑magnetic (dist)250O3PFixed/Front
A2L250 MA200/2000 FF 3P1011645136celMagnetic (motor)200O3PFixed/Front
  1. A3 Series (Frame 400A, 250-400A adjustable)
Model ExampleOrder CodeCapacitate de rupereTip de călătorieCurent nominalPolesMount/Conn
A3N400 TMF400/4000 FF 3P1011645225celThermal‑magnetic (dist)400O3PFixed/Front
A3L400 TMF315/3150 FF 4P1011645336celThermal‑magnetic (dist)315O4PFixed/Front
  1. Special Function Models
Special FunctionCodeExample ModelOrder CodeDescriere
DC ApplicationDCXT4L 250 EkipDip DC 200A FF 3P1SDA100750R1For DC circuit protection
Enhanced Environment383XT6S 800 TMA 800‑8000 FF 3P 3831SDA100751R1Operating temp -25℃~+70℃
Protecția motoruluiMA/MXT2N 160 MA100/600‑1400 FF 3P10152868Dedicated motor trip unit
Drawer MountingDXT5N 630 TMD 630‑6300 FD 3P1SDA100752R1Drawer type for easy maintenance
  1. Selecţie & Ordering Guidelines
  2. Capacitate de rupere: Select C/N/L/H/M according to system short-circuit current for safe fault interruption
  3. Trip Unit Selection

Distribution: TMD thermal-magnetic or EkipDip basic electronic

Motor protection: TMA thermal-magnetic or EkipM dedicated electronic

Complex systems: EkipC advanced electronic with full LSIG protection

  1. Tip de montare: Fixed (F) lowest cost; Plug-in (P) pentru o înlocuire ușoară; Drawer (D) for frequent maintenance
  2. Order Code Verification: ABB official codes start with 1SDA…R1 or 101…; purchase via authorized channels to avoid counterfeits
  3. Quick Selection Chart (By Current Range)
Interval de curentRecommended SeriesModel tipicSample Order Code
16–160AXT1/XT2/A1XT2N 160 TMD R100 FF 3P1SDA100730R1
160–250AXT3/XT4/A2XT4L 250 EkipDip 200A FF 3P1SDA100738R1
250–630AXT5/A3XT5N 630 TMD 630‑6300 FF 3P1SDA100743R1
630–1000AXT6XT6S 800 EkipDip 800A FF 3P1SDA100741R1
1000–1600AXT7XT7M 1200 EkipC 1200A FF 3P1SDA100748R1

Prev:

Următorul:

Lasă un răspuns