Mitsubishi FR-A840-02600-2-60 Inverter - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

Mitsubishi FR-A840-02600-2-60 Inverter - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

invertor solar/electric/

Mitsubishi FR-A840-02600-2-60 Inverter

  Model Segment Description FR General prefix for Mitsubishi inverters (Frequency Inverter) A840 Standard model of A800 series for 400V class, high-performance vector control for general industrial use 2600 Capacity code, corresponding to Normal Duty (ND) 90kW/180A, Super Light Duty (SLD) 132kW/260A 2 CA type (current control, standard 0–20mA analog input) 60 Conformal coating on ...

  • Detalii despre produs

 

Segmentul de modelDescriere
FRGeneral prefix for Mitsubishi inverters (Frequency Inverter)
A840Standard model of A800 series for 400V class, high-performance vector control for general industrial use
2600Capacity code, corresponding to Normal Duty (ND) 90kW/180A, Super Light Duty (SLD) 132kW/260A
2CA type (current control, standard 0–20mA analog input)
60Conformal coating on circuit boards, non-plated conductors, enhanced environmental resistance
  1. Core Electrical Specifications
ArticolNormal Duty (ND)Super Light Duty (SLD)Light Duty (LD)
Applicable Motor Power90kW (150HP)132kW (177HP)110kW (147HP)
Rated Output Current180O260O216O
Putere de intrare3-phase AC 380–480V, 50/60Hz (±10% tolerance)
Tensiune de ieșire3-phase AC 0–input voltage, proportional to input voltage
Output Frequency0.2–590Hz (max 400Hz in vector control mode)
Control MethodSensorless Vector Control (RSV), Control V/F, PM Sensorless Vector Control, compatible with Induction Motors (IM) and Permanent Magnet Motors (IPM)
  1. Key Features
  2. High‑Performance Control

Universal vector control, high torque at low speed; 150% rated torque at 0.5Hz

Built-in PID controller for various closed-loop applications

Automatic energy-saving operation, adjusts output voltage according to load to reduce power consumption

  1. Structura & Protecţie

Protection class IP00 (open type), suitable for cabinet mounting

Circuit boards with conformal coating (conform cu IEC 60721-3-3), resistant to dust, oil, and humidity

Protecție cuprinzătoare: supracurent, supratensiune, subtensiune, supraîncălzire, earth fault, motor overload, phase loss protection, etc.

  1. Built-in Interfaces & Expandability

Standard RS-485 communication (Modbus RTU protocol)

Supports various fieldbus extensions: PROFIBUS-DP, DeviceNet, EtherNet/IP, etc.

Analog inputs: 2 canale (0–10V / 0–20mA, 1 channel dedicated for CA-type 0–20mA)

Digital I/O: 5 inputs, 2 outputs (expandable)

  1. Capacitate de suprasarcină & Parametrii de mediu
Tip de încărcareCapacitate de suprasarcinăCondiții de mediu
Normal Duty (ND)150% curent nominal pentru 60 de secunde, 200% rated current for 3s (inverse-time characteristic)Operating temp: -10℃to 50℃C (derating above 40℃C)
Super Light Duty (SLD)110% curent nominal pentru 60 de secunde, 120% rated current for 3sStorage temp: -20℃ to 65℃
Light Duty (LD)120% curent nominal pentru 60 de secunde, 150% rated current for 3sRelative humidity: 5% la 95% (necondens)
  1. Aplicații tipice

General industrial machinery: compresoare, pompe, fani, transportoare, mixere, etc.

Metal processing: fusuri de mașini-unelte, winding equipment, wire drawing machines

Lifting & conveying: macarale, lifturi, automated storage systems

Chemical & farmaceutic: mixing, reaction, and conveying equipment in process industries

Clădire & HVAC: sisteme de aer conditionat, pompe, fan energy-saving control

  1. Instalare & Ghid de selecție
  2. Cerințe de instalare

Forced-air cooling; ensure sufficient ventilation (≥100mm clearance on all sides)

Montați vertical, avoid direct sunlight and corrosive gas environments

Recommended input reactor and EMC filter for improved stability and EMC performance

  1. Note de selecție

Select load rating based on actual load type (constant torque / variable torque)

For frequent starting/stopping or heavy starting, select one frame size larger than motor power

For long cable runs, consider voltage drop and dv/dt effects; install output reactor if necessary

  1. Replacement Models & Informații de comandă

Înlocuire directă: FR-A840-02600-E2-60 (European version, no built-in DC reactor)

Upgraded model: FR-A840-02600-E2-60CRN (with Ethernet interface)

Official order number: 297582 (base model)

The Mitsubishi FR-A840-02600-2-60 is a high-performance, high-reliability 400V-class vector inverter, ideal for driving medium-to-high power motors and providing precise speed and torque control in various industrial automation scenarios. Its CA-type control and conformal coating ensure excellent performance in harsh industrial environments.

Mitsubishi FR Series Inverter Model List & Cross-Brand Comparison

  1. Classification & Model Meaning of Mitsubishi FR Series

1.1 Series Overview

SerieClasa de tensiuneGama de putereCore PositionAplicații tipice
FR-A800200V (FR-A820) / 400V (FR-A840)0.4kW–500kWFlagship high-performance vector controlIndustrie grea, high-precision torque control, complex motion control
FR-F800200V (FR-F820) / 400V (FR-F840)0.4kW–400kWEnergy-saving for fans & pompeHVAC, water treatment, building automation
FR-E800/FR-E700200V/400V0.1kW–22kWCompact general-purposePackaging machinery, food & beverage, small production lines
FR-D800/FR-D700200V/400V0.1kW–75kWEasy-to-use economy typeSmall fans/pumps, transportoare, general machinery
FR-CS80200V/400V0.4kW–315kWHeavy-duty special typeCranes, winders, metallurgical equipment
FR-B200V/400V0.4kW–75kWExplosion-proof special typeHazardous areas such as chemical, petroleum, mine de cărbune

1.2 Full Model Format Explanation

Standard format: FR-XXX-YYYYY-Z-W

FieldSensExemplu
FRGeneral prefix for Mitsubishi inverters (Frequency Inverter)
XXXCod de serie + clasa de tensiuneA840 (400V high-performance), F820 (200V fan/pump)
YYYYYCapacity code/power identifier02600 (90kW/180A), 15K (15kW)
ZControl type1 (standard, 0–10V), 2 (CA type, 0–20mA), E2 (European version, no built-in DC reactor)
WSpecial functions60 (conformal coating), CRN (Ethernet), R2R (winding dedicated)
  1. Complete Model List of Mitsubishi FR Series Inverters

2.1 FR-A840 (400V High-Performance Vector Control) Core Models

Applicable Motor PowerND CurrentSLD CurrentBase ModelSpecial Model
0.75kW2.1O3.0OFR-A840-00038-2-60FR-A840-00038-E2-60
1.5kW3.7O5.3OFR-A840-00052-2-60
2.2kW5.0O7.2OFR-A840-00072-2-60
5.5kW11.5O16.5OFR-A840-00170-2-60
11kW23O33OFR-A840-00330-2-60
15kW30O43OFR-A840-00430-2-60
30kW60O86OFR-A840-00860-2-60FR-A840-00860-E2-60
90kW180O260OFR-A840-02600-2-60FR-A840-02600-E2-60
132kW240O345OFR-A840-03450-2-60
280kW500O720OFR-A840-07200-2-60

2.2 Representative Models of Other Main Series

SerieRepresentative ModelPutereKey Features
FR-F840FR-F840-5.5K-25.5kWFan/pump dedicated, built-in PID, energy-saving control
FR-E740FR-E740-1.5K-CHT1.5kWCompact, built-in EMC filter
FR-D740FR-D740-7.5K-CHT7.5kWSimple operation, rentabil
FR-A820FR-A820-37K-137kW200V high-performance, suitable for light industry
  1. Cross-Brand Inverter Comparison Table

Below shows functional and power matching between Mitsubishi FR series and major brands including Siemens, Schneider, ABB. Precise selection should consider actual load characteristics and control requirements.

Mitsubishi ModelSiemens EquivalentSchneider EquivalentABB EquivalentFunctional Match
FR-A840-02600-2-60 (90kW)SINAMICS G120C 90kWATV630D11N4ACS580-01-180A-4High-performance vector control, suitable for heavy-duty applications
FR-F840-5.5K-2 (5.5kW)SINAMICS G120X 5.5kWATV610U75N4ACS580-01-015A-4Fan/pump dedicated, energy-saving control
FR-E740-1.5K (1.5kW)SINAMICS V20 1.5kWATV320U15N4ACS180-04-03A3-4Compact general-purpose
FR-A820-37K-1 (37kW, 200V)SINAMICS G120 37kW 200VATV630D45N2ACS580-04-075A-2Medium-power vector control for 200V systems
FR-CS840-110K (110kW)SINAMICS S120 110kWATV930D160N4ACS880-01-246A-3Heavy-duty, four-quadrant operation
  1. Puncte cheie ale selecției & Note
  2. Load Matching Principles

Constant torque loads (transportoare, mixere): select FR-A800 series, rated by ND current

Variable torque loads (fani, pompe): select FR-F800 series, rated by SLD current

Frequent start/stop or heavy starting: select one size larger than motor power

  1. Special Environment Adaptation

Harsh industrial environments: prefer models with “60” suffix (conformal coating: FR-A840-XXXXX-2-60)

Explosive/flammable environments: select FR-B series explosion-proof inverters

Ethernet communication: select models withCRNsuffix

  1. Instalare & Sfaturi de întreținere

Vertical mounting, ≥100mm clearance on all sides for ventilation

For long cables, recommend output reactor to reduce dv/dt influence

Regular inspection of cooling fans and capacitors for long-term stable operation

Mitsubishi FR series inverters cover a full power range from 0.1kW to 500kW, meeting diverse needs from basic control to high-precision motion control via differentiated series positioning. For cross-brand selection, focus on core parameters including control method, capacitate de suprasarcina, communication protocol, and environmental resistance to ensure system compatibility and stability.

Prev:

Următorul:

Lasă un răspuns