Schneider A9F18216

: iC65N 2P C16A Schneider A9F18216 Miniature Circuit Breaker First, it should be clarified that A9F18216 is a miniature circuit breaker (MCB) of the iC65N series, not an RCBO (Residual Current Circuit Breaker with Overcurrent protection). An RCBO is an integrated device with overload, short-circuit and earth leakage protection, while A9F18216 only provides overload and ...

  • Detalii despre produs

: iC65N 2P C16A Schneider A9F18216 Miniature Circuit Breaker

Primul, it should be clarified that A9F18216 is a întrerupător miniatural (MCB) of the iC65N series, not an RCBO (Residual Current Circuit Breaker with Overcurrent protection). An RCBO is an integrated device with overload, short-circuit and earth leakage protection, while A9F18216 only provides overload and short-circuit protection. For earth leakage protection, it must be used with an additional Vigi iC60 or QuickVigi iC60 residual current module.

Model Code Breakdown

Model PartSens
iC65NProduct series: Acti9 iC65 series; N stands for 6kA breaking capacity
2PNumărul de poli: 2 stâlpi (Line + Neutru)
CCurba de declanșare: Tip C, for power distribution and lighting circuits; instantaneous tripping at 5–10× rated current
16OCurent nominal: 16 amperi
A9F18216Schneider official order code

Core Technical Specifications

ArticolDetailed Specification
Tip de produsÎntrerupător în miniatură (MCB)
SerieActi9 iC65N
Numărul de poli2P (2-sistem de sârmă, 2 protected poles)
Curent nominal (În)16O
Curba de declanșareTip C
Capacitate de rupere (Icu)6cel (400V și)
Tensiune nominală230/400V și
Frecvenţă50/60Hz
Dimensiuni2 module (36mm latime)
MontareMontare pe șină DIN
Degree of ProtectionIP20
Tip de declanșareTermo-magnetic (suprasarcina: bimetal strip; scurtcircuit: magnetic coil)
Standarde aplicabileIEC 60898-1

Caracteristicile produsului & Functions

  1. Reliable Protection: Provides overload and short-circuit protection to prevent electrical fires and equipment damage
  2. Curba de tip C: Suitable for power distribution, lighting circuits and resistive loads, with good inrush current tolerance
  3. Design compact: 2-lățimea modulului, saving space in distribution boards
  4. VisiTrip Indicator: Red mechanical window shows trip status for quick fault diagnosis
  5. Multiple Wiring Methods: Supports front, rear and rail-mounted wiring to meet various installation needs
  6. Wide Operating Temperature Range: -25°C to +40°C, adaptable to various environments

Difference from RCBO and Earth Leakage Protection Solutions

Tip de produsFuncții de protecțieModel tipicInstalare
A9F18216 (iC65N 2P C16A)Supraîncărcare + Short-circuitA9F18216Standalone
RCBO (iC65N Vigi+)Supraîncărcare + Short-circuit + Earth LeakageA9D11216 (2P C16A 30mA Type A)Integrated
MCB + Leakage ModuleSupraîncărcare + Short-circuit + Earth LeakageA9F18216 + A9Q41216 / A9V41216Module attached to right of MCB

To upgrade A9F18216 to a system with earth leakage protection, you may choose:

QuickVigi iC60 2P 16A 30mA module (A9Q41216, 1.5 module, space-saving)

Vigi iC60 2P 16A 30mA module (A9V41216, 3 module, standard version)

Aplicații

Suitable for overload and short-circuit protection in final distribution systems, especially for:

Lighting circuits in residential and commercial buildings

Circuits for small power equipment and resistive loads

Branch protection in distribution boards

Applications requiring flexible combination with earth leakage modules

Key Installation & Operating Instructions

  1. Montat pe șină DIN standard de 35 mm
  2. Interval de temperatură de funcționare: -25°C to +40°C
  3. Pollution degree: 3
  4. Tensiune nominală de rezistență la impuls (Ump): 6kV
  5. Capacitatea cablajului: max. 25mm² cable
  6. Mechanical endurance: 20,000 operating cycles

A9F18216 is a commonly used 2P 16A Type C MCB from Schneider’s Acti9 series, offering reliable overload and short-circuit protection. If earth leakage protection is required, a corresponding residual current module must be added, or an RCBO from the iC65N Vigi+ series (de ex., A9D11216) can be selected directly.

Supplementary Information for Schneider A9F18216: Official Ordering, Full Series List & Chinese Domestic Alternatives

  1. Official Ordering Information
ArticolDetails
Product NameiC65N 2P C16A Miniature Circuit Breaker (MCB)
Official Order CodeA9F18216
SerieActi9 iC65N (N = 6kA breaking capacity)
Cadrul curent63O
Tensiune nominală230/400V și
Frecvenţă50/60Hz
Capacitate de rupere (Icu)6cel (400V și)
Curba de declanșareTip C (instantaneous trip at 5–10× In)
Numărul de poli2P (2-wire, Line + Neutru)
Curent nominal16O
Dimensiuni2 module (36mm latime)
MontareMontare pe șină DIN
Degree of ProtectionIP20
Standarde aplicabileIEC 60898-1, GB 14048.2
Capacitatea cablajuluiMax. 25mm² cable
Mechanical Endurance20,000 operating cycles
Perioada de garanție12 luni
  1. Full Model List of iC65N Series (A9F Prefix)

The iC65N series is categorized by pole number. Order code rule: A9F + [Pole Code] + [Current Code]

Pole codes: 11=1P, 12=2P, 13=3P, 14=4P

Current codes: 06=6A, 08=8A, 10=10A, 13=13A, 16=16A, 20=20A, 25=25A, 32=32A, 40=40A, 50=50A, 63=63A

1P Models (A9F181xx)

Curent nominalOrder CodeCurba de declanșare
6OA9F18106Tip C
8OA9F18108Tip C
10OA9F18110Tip C
13OA9F18113Tip C
16OA9F18116Tip C
20OA9F18120Tip C
25OA9F18125Tip C
32OA9F18132Tip C
40OA9F18140Tip C
50OA9F18150Tip C
63OA9F18163Tip C

2P Models (A9F182xx)

Curent nominalOrder CodeCurba de declanșare
6OA9F18206Tip C
8OA9F18208Tip C
10OA9F18210Tip C
13OA9F18213Tip C
16OA9F18216Tip C
20OA9F18220Tip C
25OA9F18225Tip C
32OA9F18232Tip C
40OA9F18240Tip C
50OA9F18250Tip C
63OA9F18263Tip C

3P Models (A9F183xx)

Curent nominalOrder CodeCurba de declanșare
6OA9F18306Tip C
8OA9F18308Tip C
10OA9F18310Tip C
13OA9F18313Tip C
16OA9F18316Tip C
20OA9F18320Tip C
25OA9F18325Tip C
32OA9F18332Tip C
40OA9F18340Tip C
50OA9F18350Tip C
63OA9F18363Tip C

4P Models (A9F184xx)

Curent nominalOrder CodeCurba de declanșare
6OA9F18406Tip C
8OA9F18408Tip C
10OA9F18410Tip C
13OA9F18413Tip C
16OA9F18416Tip C
20OA9F18420Tip C
25OA9F18425Tip C
32OA9F18432Tip C
40OA9F18440Tip C
50OA9F18450Tip C
63OA9F18463Tip C

Modele speciale (Tip D / Capacitate mare de rupere)

ModelDescriereOrder Code
iC65N 2P D16AType D curve (10–14×In), for motor loadsA9F18216D
iC65H 2P C16AHigh breaking capacity 10kAA9F18216H
iC65L 2P C16ALow breaking capacity 4.5kAA9F18216L
  1. Chinese Domestic Brand Alternatives (2P C16A MCB)
MarcaSerieModelCapacitate de rupereKey FeaturesPreț de referință
CHINTEditura-63NXB-63 2P C16A6celLeading domestic brand, rentabil, CCC certified40–50% of Schneider
DELIXIDZ47sDZ47s 2P C16A6celWell-known domestic brand, reliable quality, widely used40–50% of Schneider
NAXINNDM1NDM1-63 2P C16A6celIndustrial-grade quality, suitable for engineering projects50–60% of Schneider
Comutator ChangshuCH1CH1-63 2P C16A6celEstablished state-owned enterprise, mature technology50–60% of Schneider
People ElectricRMK-63RMK-63 2P C16A6celPreț accesibil, suitable for bulk purchase30–40% of Schneider

Key Selection Guidelines for Alternatives

  1. Matching breaking capacity: Ensure alternative ≥6kA, same as iC65N
  2. Matching tripping curve: Type C for power/lighting; Type D for motors
  3. Dimension compatibility: All 2 module (36mm), DIN rail mount, fits distribution boards
  4. Complete certification: Must have CCC; CE recommended for industrial use
  5. Capacitatea cablajului: Ensure max. wiring ≥25mm² to meet site requirements
  6. Earth Leakage Protection Upgrade Solutions

Two options to upgrade A9F18216 with earth leakage protection:

Option 1: MCB + Leakage Module Combination

Module TypeModelCaietul de sarciniLăţimeOrder Code
QuickVigi iC602P 16A 30mA ACCompact 1.5 module27mmA9Q41216
Vigi iC602P 16A 30mA ACStandard 3 module63mmA9V41216
Vigi iC602P 16A 30mA ADetects pulsating DC leakage63mmA9V42216

Option 2: Direct Replacement with RCBO

Schneider RCBO ModelDescriereOrder Code
iC65N Vigi+ 2P C16A 30mA AIntegrated leakage protectionA9D11216
iC65N Vigi+ 2P C16A 30mA ACIntegrated leakage protectionA9D10216

A9F18216 is the standard 2P C16A model in the Schneider iC65N series with clear ordering information. The series covers various pole numbers and current ratings. Abundant Chinese domestic alternatives are available for flexible selection based on project budget and quality requirements. Earth leakage protection can be achieved by adding a leakage module or replacing with an RCBO to ensure safe and reliable electrical systems.

Full Model List of Schneider A9F18216 in the Same Series (iC65N Series)

  1. Model Coding Rule Explanation

The coding rule for A9F-prefixed order codes of Schneider iC65N series MCBs is as follows:

Code PartSens
A9FProduct category: Acti9 iC65 MCB
17Type B curve (instantaneous trip at 2–5×In)
18Type C curve (instantaneous trip at 5–10×In, standard for lighting & distribution)
19Type D curve (instantaneous trip at 10–14×In, for motor loads)
1/2/3/4Numărul de poli: 1=1P, 2=2P, 3=3P, 4=4P
01/02/04/06…63Curent nominal: 1O, 2O, 4O, 6O…63O
  1. Full Model List (By Pole Number)

2.1 1P Models (A9F[17/18/19]1xx)

Curent nominalTip B (A9F171xx)Tip C (A9F181xx)Tip D (A9F191xx)
1OA9F17101A9F18101A9F19101
2OA9F17102A9F18102A9F19102
4OA9F17104A9F18104A9F19104
6OA9F17106A9F18106A9F19106
8OA9F17108A9F18108A9F19108
10OA9F17110A9F18110A9F19110
13OA9F17113A9F18113A9F19113
16OA9F17116A9F18116A9F19116
20OA9F17120A9F18120A9F19120
25OA9F17125A9F18125A9F19125
32OA9F17132A9F18132A9F19132
40OA9F17140A9F18140A9F19140
50OA9F17150A9F18150A9F19150
63OA9F17163A9F18163A9F19163

2.2 2P Models (A9F[17/18/19]2xx)

Curent nominalTip B (A9F172xx)Tip C (A9F182xx)Tip D (A9F192xx)
1OA9F17201A9F18201A9F19201
2OA9F17202A9F18202A9F19202
4OA9F17204A9F18204A9F19204
6OA9F17206A9F18206A9F19206
8OA9F17208A9F18208A9F19208
10OA9F17210A9F18210A9F19210
13OA9F17213A9F18213A9F19213
16OA9F17216A9F18216A9F19216
20OA9F17220A9F18220A9F19220
25OA9F17225A9F18225A9F19225
32OA9F17232A9F18232A9F19232
40OA9F17240A9F18240A9F19240
50OA9F17250A9F18250A9F19250
63OA9F17263A9F18263A9F19263

2.3 3P Models (A9F[17/18/19]3xx)

Curent nominalTip B (A9F173xx)Tip C (A9F183xx)Tip D (A9F193xx)
1OA9F17301A9F18301A9F19301
2OA9F17302A9F18302A9F19302
4OA9F17304A9F18304A9F19304
6OA9F17306A9F18306A9F19306
8OA9F17308A9F18308A9F19308
10OA9F17310A9F18310A9F19310
13OA9F17313A9F18313A9F19313
16OA9F17316A9F18316A9F19316
20OA9F17320A9F18320A9F19320
25OA9F17325A9F18325A9F19325
32OA9F17332A9F18332A9F19332
40OA9F17340A9F18340A9F19340
50OA9F17350A9F18350A9F19350
63OA9F17363A9F18363A9F19363

2.4 4P Models (A9F[17/18/19]4xx)

Curent nominalTip B (A9F174xx)Tip C (A9F184xx)Tip D (A9F194xx)
1OA9F17401A9F18401A9F19401
2OA9F17402A9F18402A9F19402
4OA9F17404A9F18404A9F19404
6OA9F17406A9F18406A9F19406
8OA9F17408A9F18408A9F19408
10OA9F17410A9F18410A9F19410
13OA9F17413A9F18413A9F19413
16OA9F17416A9F18416A9F19416
20OA9F17420A9F18420A9F19420
25OA9F17425A9F18425A9F19425
32OA9F17432A9F18432A9F19432
40OA9F17440A9F18440A9F19440
50OA9F17450A9F18450A9F19450
63OA9F17463A9F18463A9F19463
  1. Special Versions (Capacitate de rupere / Extinderea funcției)
ModelDescriereOrder CodeObservații
iC65H 2P C16AHigh breaking capacity 10kAA9F18216HH = High breaking
iC65L 2P C16ALow breaking capacity 4.5kAA9F18216LL = Low breaking
iC65N 2P C16A RWith overload alarm contactA9F18216RR = With alarm contact
iC65N 2P C16A DCFor DC circuits onlyA9F18216DCFor DC system protection
  1. Unified Key Technical Specifications

All A9F-prefixed iC65N models share the following core parameters:

Capacitate de rupere (Icu): 6cel (400V și)

Tensiune nominală: 230/400V și

Frecvenţă: 50/60Hz

Dimensiuni: 1P=1 module (18mm), 2P=2 modules (36mm), 3P=3 modules (54mm), 4P=4 modules (72mm)

Montare: Montare pe șină DIN

Degree of Protection: IP20

Tripping type: Termo-magnetic (suprasarcina: bimetal strip; scurtcircuit: magnetic coil)

Applicable standards: IEC 60898-1, GB 14048.2

  1. Selection Guide
  2. Tripping Curve Selection

Tip B: For pure resistive loads (de ex., incandescent lamps)

Tip C: For general power and lighting loads (most commonly used)

Tip D: For inductive loads such as motors and transformers

  1. Selectarea numărului de pol

1P: Protects line only, for single-phase lighting circuits

2P: Protects line + neutral, for single-phase socket circuits

3P: Protects three phases, for three-phase power circuits

4P: Protects three phases + neutral, for three-phase four-wire systems

  1. Breaking Capacity Selection

Type N (6cel): For general residential and commercial buildings

Tip H (10cel): For industrial sites or distribution systems near transformers

Type L (4.5cel): For simple lighting systems