Schneider Electric GV2-ME21C

Schneider Electric GV2-ME21C is a 3-pole thermal-magnetic motor protection circuit breaker belonging to the TeSys GV2M series. Its core parameters cover electrical, protecţie, mechanical and environmental dimensions. Below is the structured and complete technical parameter sheet:

  1. Basic Electrical Parameters
Element de parametruValoareStandard/Remarks
Rated Operating Voltage (Ue)690V și (IEC 60947-2); 600V și (UL 508)Suitable for three-phase industrial circuits
Tensiune nominală de izolație (Ui)690V șiBenchmark for insulation safety
Rated Impulse Withstand Voltage (Uimp)6kVSurge resistance capability
Thermal Overload Setting Current (Ir)17-23O10-level adjustable, suitable for motors of corresponding power
Rated Operating Current (Ith)23OUpper limit of long-term current carrying capacity
Numărul de pol3-polProtection for the main circuit of three-phase motors
Utilization CategoryAC-3 (IEC 60947-4-1); Category A (IEC 60947-2)Suitable for motor starting, stopping and operation
Control MethodPush-button type (handle operation)Convenient for closing, opening and trip testing
  1. Protection and Breaking Capacity
Element de parametruValoareApplicable Conditions
Ultimate Short-Circuit Breaking Capacity (Icu)3kA@690V AC; 15kA@400/415V AC; 50kA@230/240V AC; 6kA@440V AC; 4kA@500V AC50/60Hz, compliant with IEC 60947-2
Service Short-Circuit Breaking Capacity (Ics)75% Icu@690V AC; 50% Icu@440V ACCan continue to be used after breaking
Magnetic Trip Current327-390O (approx. 15-17 times of Ir)Threshold for instantaneous short-circuit protection
Protecție împotriva pierderii de fazăAvailableReliable tripping in case of three-phase unbalance
Thermal Overload Protection10-level ambient compensationSuitable for working conditions from -20℃ to +60℃
  1. Mechanical and Installation Parameters
Element de parametruValoareStandard/Remarks
Metoda de montare35mm standard DIN rail (ÎN 60715) / screw mountingDIN rail mounting is preferred; screw hole spacing is approx. 45mm
Mounting PositionHorizontal/VerticalFlatness error ≤ 0.5mm/m
Tip terminalScrew-clamp typeSuitable for 2.5-4mm² copper core wires, torque 1.5-2.5N·m
Dimensiuni generale (H×W×D)89mm×44.5mm×78.2mmCompact design, saving cabinet space
GreutateApprox. 0.26kgLightweight, easy to install
Electrical Service Life100,000 operațiuniDurability of closing and opening cycles
Mechanical Service Life200,000 operațiuniReliability of the operating mechanism
  1. Environmental and Protection Parameters
Element de parametruValoareStandard/Remarks
Ingress Protection Rating (IP)IP20 (main unit)IEC 60529, protection against finger touch
Mechanical Impact Resistance Rating (IK)IK04Resistance to mechanical impact
Temperatura de operare-20℃~+60℃Wide temperature range for industrial applications
Temperatura de depozitare-40℃~+85℃No condensation or corrosive gas
CertificariIEC, UL, CSA, CCC, EAC, Green Premium (RoHS/REACH)Compliant with multiple global regional standards
  1. Applicable Motor Power (Reference)
Voltage LevelApplicable Motor Power
400/415V și9kW
500V și11kW
690V și18.5kW
  1. Supplementary Core Features
  2. The handle can be locked in the OFF position to prevent accidental closing and improve maintenance safety.
  3. Auxiliary contact modules such as GV2-AE11 (1NU+1NC) can be added for signal feedback or control circuit expansion.
  4. The terminals are suitable for multi-strand flexible wires (cold-pressed terminals are required) to avoid heating caused by loose wiring.