Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Code Designations for Model 440RB23020C

(Standard Format: 440R-B23020/C)

Core Description

This is a safety monitoring relay from the Allen-Bradley (Rockwell Automation) Guardmaster Minotaur MSR5T Series, Series C version. It is intended for low-risk safety applications in industrial automation systems, such as safety gate monitoring and emergency stop button control.

1 Complete Model Breakdown

Модельный сегментStandard FormatОписание
440Р440РProduct family identifier for Rockwell Automation Bulletin 440R safety relays, part of the Guardmaster safety product range
БSubseries code, representing the MSR5T Series (Minotaur Safety Relay Type 5T monitoring safety relay)
2302023020Function and configuration code, detailed as follows:
– 2: Supply type (universal 24V AC/DC power supply)
– 3: Number of safety outputs (3 normally open NO safety outputs)
– 0: Auxiliary output type (1 normally closed NC auxiliary output)
– 2: Input configuration (1 normally closed NC single‑channel input, for safety gate interlocks and E‑stop buttons)
– 0: Reset type (selectable automatic / manual reset via jumper)
СSeries version code, indicating Series C, the latest production version with firmware updates and performance improvements

2 Detailed Explanation of Each Code

  1. 440R – Product Family Identifier

440: Standard prefix for Rockwell Automation safety products, dedicated to the Guardmaster safety relay line

Р: Abbreviation for Relay, defining the product as a safety relay, distinguishing it from other 440-series devices such as safety switches (440Г) and safety controllers (440С)

  1. B – Subseries Code (MSR5T)

B Corresponds exclusively to the Minotaur MSR5T model, a monitoring safety relay with key features:

Single-or dual-channel input (this model uses 1NC single-channel input)

3 independent redundant normally open safety outputs to ensure reliable safety function

1 normally closed auxiliary output for status feedback signals

Supports output monitoring to detect faults in the safety output circuit

  1. 23020 – Detailed Function Configuration Code
DigitЗначениеValue in This ModelСпецификация
1st digit (2)Supply type2Universal 24V AC/DC power supply, wide‑range design for various control systems
2nd digit (3)Number of safety outputs33 нормально открытый (НЕТ) safety outputs for direct control of contactors or actuators
3rd digit (0)Auxiliary output type01 нормально закрытый (Северная Каролина) auxiliary output for PLC status feedback or indicator control
4th digit (2)Input configuration21 нормально закрытый (Северная Каролина) single‑channel input for low‑risk applications
5th digit (0)Reset type0Selectable automatic / manual reset via jumper on terminals X1‑X2
  1. C – Series Version Code

C Indicates the product is Series C, the latest production version

Version differences:

Series A: Original version

Серия Б: Improved version with partial functional optimizations

Series C: Latest version with firmware updates, performance enhancements, and compatibility improvements

All series versions are fully functionally compatible and can be directly interchanged

3 Ключевые технические параметры (for 440R-B23020/C)

ПараметрСпецификация
Тип продуктаMinotaur MSR5T safety monitoring relay
Safety RatingКатегория 4, PLe (ISO 13849‑1), SIL 3 (МЭК 61508), Stop Category 0
Input Configuration1 нормально закрытый (Северная Каролина) single‑channel input, suitable for safety gate interlocks and emergency stop buttons
Output Configuration3 нормально открытый (НЕТ) safety outputs + 1 нормально закрытый (Северная Каролина) auxiliary output
Supply Voltage24В переменного/постоянного тока (universal power supply)
Reset MethodАвтоматический / manual reset (selectable via jumper)
МонтажМонтаж на DIN-рейку (В 60715 compliant), ширина 22.5 мм
Степень защитыIP20 (передний)
Рабочая температура-25 °С до +60 °С

4 Application Areas & Selection Guidelines

Типичные применения

Safety gate monitoring (low-risk applications)

Emergency stop button control

Safety circuit monitoring for small machinery

Ключевые моменты выбора

Confirm input type: ensure single-channel 1NC input meets safety device connection requirements

Check output quantity: verify 3 NO safety outputs + 1 NC auxiliary output satisfy control circuit demands

Verify supply compatibility: confirm 24V AC/DC universal power matches system voltage

Version selection: Series C is the latest version and recommended for priority use

 

Предыдущий:

Следующий:

Оставить ответ