Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

ABB ESB20-20N-06 контактор - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

контактор/

ABB ESB20-20N-06 контактор

ABB ESB20-20N-06 Technical Analysis Report This is a 2-pole, 20А, 2НЕТ, 230V AC/DC universal coil modular installation contactor, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620. Модель ...

  • Подробная информация о продукте

ABB ESB20-20N-06 Technical Analysis Report

This is a 2-pole, 20А, 2НЕТ, 230V AC/DC universal coil modular installation контактор, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620.

  1. Model Breakdown
Модельный сегментОписание
ESBProduct family: ABB ESB series building / installation contactors
20Номинальный ток: 20А (AC-1 duty)
20Main contact configuration: 2 НЕТ, 0 Северная Каролина
НFamily identifier: Standard ESB..N installation contactor (vs. EN..N with manual switch)
6Coil voltage code: 230V AC/DC universal
  1. Основные характеристики

Electrical Data

ЭлементЦенитьПримечания
Rated operational current (АС-1)20АResistive load
Rated operational power (АС-7а, 230В)4.6кВтSingle-phase motor load
Rated operational current (АС-3, 230В)Single-phase motor load
Номинальное напряжение изоляции (Уи)400ВIEC compliant
Rated impulse withstand voltage (Умп)6кВIEC compliant
Coil voltage230В переменного/постоянного токаUniversal, no polarity required
Coil powerInrush: ~12VA/10WLow-power, energy-saving design
Sealed: ~2VA/2W
Control circuit frequency50/60ГцUniversal range

Mechanical & Environmental Data

ЭлементЦенитьПримечания
Number of poles22 main circuits
Конфигурация контактов2НЕТ + 0Северная КаролинаNo auxiliary contacts
Mechanical durability1,000,000 операцииHigh endurance
Electrical durability (AC-7a/7b)150,000 операцииМЭК 60947-4-1 compliant
Ширина18ммМодульный, space-saving
Монтаж35мм DIN-рейкаStandard mounting
Рабочая температура-25°C ~ +55°CWide temperature range
Температура хранения-40°C ~ +85°CHigh-reliability design
Степень защитыIP20Finger-safe, suitable for distribution boards
  1. Function Description
  2. Universal coil technology: AC/DC universal coil, no AC/DC distinction, flexible installation, completely silent and vibration-free operation.
  3. Integrated overvoltage protection: Built-in overvoltage suppression in control circuit, improves system reliability and service life.
  4. Модульная конструкция: Only 18mm wide, fully compatible with other modular DIN rail components, saves cabinet space.
  5. Совместимость аксессуаров: Supports standard accessories (вспомогательные контакты, mechanical interlocks, и т. д.), tool-free plug-and-play installation.
  6. Safety design: Complies with EN/IEC/UL standards, provides reliable electrical isolation for personnel and equipment safety.
  7. Wide application: Suitable for controlling electric heaters, hot water systems, pump/fan motors, lighting and other single-phase loads.
  8. Рекомендации по выбору

Suitable Applications

Lighting, heating, ventilation control in residential and commercial buildings

Single-phase motor control (насосы, фанаты) for small industrial equipment

Noise-sensitive environments (больницы, offices, homes)

Space-limited distribution boards / шкафы управления

Selection Criteria

  1. Load type matching:

Resistive load (АС-1): Use 20A rated current directly

Motor load (AC-7a/7b): Recommended ≤9A (4.6кВт) at 230V single-phase

Inductive load: Derating or surge suppressor recommended

  1. Coil voltage selection:

Match control system supply (230В переменного/постоянного тока)

Other voltages available: ESB20-20N-01 (24В), ESB20-20N-04 (110В)

  1. Конфигурация контактов:

This model: 2НЕТ, suitable for two independent circuits

For NC contacts: ESB20-02N series (2Северная Каролина)

For auxiliary contacts: Add auxiliary contact modules

  1. Environmental conditions:

Derate above +40°C ambient temperature

Extra protection required in humid or corrosive environments

  1. Примечания по установке

Pre-Installation

Verify model matches order, inspect for physical damage

Confirm coil voltage matches control supply

Prepare standard 35mm DIN rail and suitable terminals

Installation Procedure

Clip contactor firmly onto 35mm DIN rail

Wire main and control circuits per diagram; coil is non-polarized

Terminal torque: 2.5Н·м (conductor: 0.5–2.5mm²)

Accessories clip directly onto top/side without tools

Безопасность

Isolate and verify voltage-free before installation

Separate main and control wiring to avoid interference

Ensure adequate ventilation to prevent overheating

Maintain ≥5mm clearance around contactor for heat dissipation

Commissioning & Maintenance

Check wiring before first energization

Test contactor operation for correct switching and no abnormal noise

Inspect contacts and terminal tightness regularly (at least annually)

  1. Альтернативные модели

Same-Series Alternatives

МодельDifferenceПриложение
ESB20-20N-0124V AC/DC coilLow-voltage control systems
ESB20-20N-04110V AC/DC coil110V control systems
ESB20-02N-062NC configurationApplications requiring normally closed contacts
EN20-20N-06With manual operatorEmergency manual control

Upgraded Alternatives

МодельОбновлениеПриложение
ESB25-20N-0625Номинальный токHigher load requirements
ESB40-40N-064-столб, 40АThree-phase or higher current
ABB AF seriesIndustrial contactorsHeavy-duty industrial environments

ABB ESB20-20N-06 is a compact, high-performance installation contactor. With silent operation, universal coil, low power consumption and modular design, it is an ideal solution for single-phase load control in residential and industrial applications. Proper selection, installation and maintenance ensure long-term reliable performance and safe, efficient control for electrical systems.

ABB Contactor Standard Selection Procedure

(Industrial & Building, for sales / quotation / design)

Using ESB (building) and AF/A (промышленный) as examples – 8-step precise selection ready for proposals and quotations.

  1. Define Application & Product Family

Building / Жилой / Distribution board: Lighting, heating, насосы, фанаты, small motors → ESB/EN series (silent, DIN rail, narrow width)

Industrial / Equipment / Control cabinet: Fans, насосы, компрессоры, motor main circuits → AF/A series (wide voltage, long life, heavy-duty)

  1. Determine Load Category (Critical for Derating)

Per IEC 60947 utilization categories:

АС-1: Resistive loads (heaters, освещение) → use rated current directly

АС-3: Squirrel-cage motor DOL (most common industrial) → motor current ≤ contactor rated current

AC-7a/7b: Building small motors, фанаты, pumps → use building contactor rated values

  1. Calculate Operating Current & Rated Capacity
  2. Determine current from power / Напряжение
  3. Allow 1.1–1.25x safety margin (inrush, continuous duty)
  4. Select corresponding rated current (Т.е.) from ABB catalog

Пример: 230V single-phase 2kW heater ≈ 8.7A → ESB20-20N is sufficient

  1. Select Number of Poles

1П: Однофазный, single circuit

2П: Однофазный, double-pole (L+N switching, building standard)

3П: Three-phase motors / промышленный (most common)

4П: Three-phase + N or double-break

  1. Select Coil Voltage & Тип
  2. Control voltage: 24В, 110В, 230В, 400В, и т. д..
  3. Coil type:

Building: AC/DC universal coil (ESB series, non-polar, silent)

Industrial: Wide-range coil (AF series, stable at 85–110% Un)

  1. Define Auxiliary Contact Requirements

Встроенный: From model (20=2NO, 02=2NC)

Expandable: EH series auxiliary contacts (1НО+1НЗ, 2НЕТ, и т. д.)

Used for: Status feedback, interlocking, sequential control

  1. Относящийся к окружающей среде & Особые требования

Высота >1000м, temperature >40°C → derate or upsize

Silent requirement (residential/office): Must use ESB silent type

Защита: IP20 normally sufficient for panel mounting

Mechanical interlock / reversing: Use dedicated interlock accessories

  1. Final Verification: Модель + Сертификаты
  2. Confirm full model: family–current–contacts–coil

Пример: ESB20-20N-06

  1. Verify certifications: CCC, МЭК, RoHS
  2. Confirm mounting: 35мм DIN-рейка / screw mounting

Simplified Selection Mnemonic

  1. Choose family by application
  2. Choose duty by load type
  3. Calculate current with margin
  4. Confirm poles and coil voltage
  5. Add aux contacts for control
  6. Check environment and derate
  7. Verify model for final list

Предыдущий:

Оставить ответ

Оставить сообщение