Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

ABB MS116-4.0 MPCB - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

ABB MS116-4.0 MPCB

ABB MS116-4.0 Technical Datasheet (Manual Motor Starter / Motor Protection Circuit Breaker) Key Overview: 3-столб, rated current 4.0A (adjustable 2.5~4.0A), Class 10A tripping, 50kA/400V breaking capacity, suitable for 1.5kW/400V AC-3 motors, 45mm DIN-rail mounting, IP20 protection, global order number 1SAM250000R1008. Model Explanation Model Part Description MS116 ABB MS116 series compact 3-pole manual motor starter, integrated ...

  • Подробная информация о продукте

ABB MS116-4.0 Technical Datasheet (Manual Motor Starter / Motor Protection Circuit Breaker)

Key Overview: 3-столб, rated current 4.0A (adjustable 2.5~4.0A), Class 10A tripping, 50kA/400V breaking capacity, suitable for 1.5kW/400V AC-3 motors, 45mm DIN-rail mounting, IP20 protection, global order number 1SAM250000R1008.

  1. Model Explanation
Model PartОписание
MS116ABB MS116 series compact 3-pole manual motor starter, integrated thermal-magnetic protection (overload + short-circuit + phase failure), fuse-free design
4Rated operational current Ie = 4.0A, adjustable range 2.5~4.0A
1SAM250000R1008Global order code
Размеры / МонтажWidth 45mm, standard 35mm DIN rail mounting, IP20 degree of protection
  1. Core Electrical & Mechanical Data

2.1 Basic & Protection Parameters

ПараметрЦенитьОписание
Number of poles3-столбFor three-phase motor protection
Rated current Ie4.0АAdjustable range 2.5~4.0A
Tripping classClass 10ATypical motor tripping characteristic; trips in approx. 10 s at 10 overload current
Защита от короткого замыкания50А (fixed)Instantaneous magnetic trip, no extra fuse required
Breaking capacity Ics50тот (400В и)Rated service short-circuit breaking capacity
Номинальное напряжение690В и, 50/60ГцSuitable for various voltage systems
Applicable power (АС-3)1.5kW (400В) / 2 hp (480В)For standard motor duty
Protection functionsTemperature compensation, fuse-free protection, free tripping mechanism, isolation function, phase failure protectionComprehensive motor protection, IEC compliant

2.2 Mechanical & Mounting Data

  1. ПараметрЦенить
    Ширина45мм
    Высота90мм
    Глубина85.6мм
    Weight0.225кг
    МонтажStandard 35mm DIN rail (TH35-15/TH35-7.5)
    ConnectionScrew terminals, main circuit torque 0.8~1.2Nm
    ОперацияRotary handle (clear ON/OFF indication), free tripping mechanism
    Degree of protectionIP20 (front)
    Power consumption5.4Вт
    Температура окружающей среды-25C≈+55C

    Selection Guide

3.1 Типичные применения

Direct starting and protection of small three-phase motors (1.5kW/400V)

Control of pumps, фанаты, compressors and industrial automation equipment

Replacement of traditional “fuse + contactor” combinations to save space and cost

Applications requiring manual control and reliable motor protection

3.2 Этапы выбора

  1. Verify motor rated current: within 2.5~4.0A adjustable range
  2. Check motor power: ≤ 1.5kW (400V AC-3)
  3. Confirm system voltage: ≤ 690V AC, 50/60Гц
  4. Evaluate short-circuit current: system short-circuit current ≤ 50kA (400В)
  5. Installation space: reserve 45mm DIN rail width
  6. Ambient conditions: temperature -25°C ~ +55°C, no excessive vibration or corrosive gas

3.3 Параметр & Operation Notes

Защита от перегрузки: set to 1.0~1.1 × motor rated current (within 2.5~4.0A)

Ensure reliable phase failure protection for all three-phase motor applications

Use isolation function: safe electrical isolation after shutdown for maintenance

Can be used with contactors for remote control and automatic protection

  1. Cross-Brand Replacement Models
БрендМодельОсновные параметрыDifferences
ШнайдерGV2ME083-столб, 2.5~4.0A, Class 10, 50kA/400VSame width (45мм), functionally compatible, direct replacement
Сименс3RV2011-0JA103-столб, 2.5~4.0A, Class 10, 50kA/400VMatching mounting dimensions, compatible protection characteristics
ИтонPKZM0-43-столб, 2.5~4.0A, Class 10, 50kA/400VFunctionally and dimensionally compatible, экономически эффективный
ABB UpgradeMS132-4.03-столб, 2.5~4.0A, Class 10, 100kA/400VHigher breaking capacity, backward compatible mounting
  1. Application Notes
  2. Thermal-magnetic characteristics: Class 10A is intended for standard squirrel-cage motors; not recommended for special loads (например, трансформаторы, capacitors)
  3. Phase failure protection: Trips within 2~5 seconds if any phase is lost, effectively preventing motor burnout
  4. Fuse-free design: Eliminates external fuses, reduces cost and maintenance; ensure line short-circuit current ≤ 50kA
  5. Free tripping mechanism: Forces tripping under overload/short-circuit even in ON position, ensuring safety
  6. Temperature compensation: Protection characteristics stable over ambient temperature range -25°C ~ +55°C

Предыдущий:

Оставить ответ

Оставить сообщение