Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

 Миниатюрный автоматический выключатель Chint NB1-63H/2PC40 - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

Миниатюрный автоматический выключатель Chint NB1-63H/2PC40

Model Parameter Interpretation Model Segment Meaning NB1-63H NB1 series high-breaking-capacity miniature circuit breaker. “Hindicates a breaking capacity of 10kA (10,000А), which is higher than that of the standard version (6тот). It is suitable for circuits with large short-circuit currents. 2P 2-pole circuit breaker that controls both the live wire and neutral wire simultaneously to ...

  • Подробная информация о продукте

Model Parameter Interpretation

Model SegmentMeaning
NB1-63HNB1 series high-breaking-capacity миниатюрный автоматический выключатель. “Hindicates a breaking capacity of 10kA (10,000А), which is higher than that of the standard version (6тот). It is suitable for circuits with large short-circuit currents.
2-pole circuit breaker that controls both the live wire and neutral wire simultaneously to provide comprehensive protection.
C40C-type tripping characteristic with a rated current of 40A. C-type is designed for conventional loads (lighting, sockets, и т. д.) with an instantaneous tripping current of 5–10 times the rated current.
  1. Основные технические параметры

Номинальное напряжение: 230/400V AC (2П), suitable for 220V single-phase and 380V three-phase systems.

Номинальный ток: 40А, capable of stably carrying 40A current for long periods.

Разрывная способность: 10тот (10,000А), capable of safely interrupting short-circuit currents up to 10,000A.

Tripping Characteristic: C-type, providing reliable protection for conventional loads and avoiding nuisance tripping caused by inrush currents of motors and similar equipment.

Rated Frequency: 50/60Гц

Механическая жизнь: Примерно 20,000 операции; Электрическая жизнь: Примерно 10,000 операции.

Класс защиты: IP20, preventing the intrusion of solid foreign objects larger than 12mm.

  1. Structural and Functional Features
  2. Advantages of 2-Pole Design

Disconnects both live wire and neutral wire simultaneously for enhanced safety performance.

Both poles are equipped with trip units to provide full protection for the circuit.

Can be used as an isolating switch to facilitate circuit maintenance.

  1. High Breaking Capacity

The 10kA breaking capacity is significantly higher than that of standard models (6тот), making it ideal for modern residential and commercial power distribution systems with large short-circuit currents.

Reliably interrupts sudden short-circuit currents to protect downstream equipment and circuit safety.

  1. Thermal-Magnetic Trip Protection

Защита от перегрузки: Uses thermal elements to monitor continuous overcurrents, tripping slowly when the current exceeds the rated value (typically 1.13–1.45 times the rated current).

Защита от короткого замыкания: Uses electromagnetic elements to detect instantaneous high currents, tripping rapidly when the current reaches 5–10 times the rated current (C-type characteristic).

  1. Application Scenarios
  2. Распределение электроэнергии в жилых домах

Circuits for high-power electrical appliances in kitchens, bathrooms, и т. д.. (40A can support a load of approximately 8.8kW).

Protection for individual high-power equipment such as air conditioners and water heaters.

Floor or unit main switches, protecting both live wire and neutral wire simultaneously.

  1. Коммерческая и легкая промышленность

Power distribution systems for small offices and shops.

Distribution boxes for small production lines and equipment.

Power supply for medical and precision instruments requiring high safety standards.

  1. Special Applications

Smart home systems with high requirements for circuit protection.

Temporary power supply sites such as construction sites and exhibitions.

  1. Selection and Usage Recommendations
  2. Current Matching

The load current should not exceed the rated current (40А). It is recommended to reserve a 20% margin, то есть, the long-term operating current should not exceed 32A.

Power calculation: For a 220V single-phase system, the maximum load is approximately 8.8kW (40A × 220V).

  1. Выбор номера полюса

– 2P is suitable for scenarios requiring simultaneous disconnection of live wire and neutral wire, offering higher safety than 1P.

– 2P occupies 2 module spaces (36мм), so it is necessary to check if the distribution box has sufficient space.

  1. Tripping Characteristic Selection

C-type: Standard type, suitable for conventional loads such as lighting, sockets, and household appliances.

D-type: Designed for loads with high inrush currents such as motors (instantaneous tripping current is 10–20 times the rated current).

The Chint NB1-63H/2PC40 is a high-performance 2-pole miniature circuit breaker with 10kA high breaking capacity and C-type tripping characteristic, specifically designed for modern residential and commercial power distribution systems. The 2-pole structure protects both live wire and neutral wire simultaneously, and the 40A rated current can meet the power demand of most households and small commercial establishments, making it a safe and reliable choice for circuit protection.

Comparison Between Chint NB1-63H/2PC40 and NXB63H-1P/16A Circuit Breakers

  1. Core Parameter Comparison
ParameterNB1-63H/2PC40NXB63H-1P/16ADifference Description
Series PositioningNB1 series (high-end industrial grade)NXB series (cost-effective entry grade)The NB1 series offers higher performance, adapts to a wide temperature range of -35℃~70℃, and has passed 7,860 rigorous tests.
Номер полюса2П (2-pole)1П (1-pole)2P protects both live wire and neutral wire simultaneously for higher safety; 1P only protects the live wire.
Номинальный ток40А16А40A can support a power load of approximately 8.8kW; 16A can support approximately 3.5kW.
Tripping CharacteristicC-type (стандартный)C-type (стандартный)Identical; the short-circuit tripping current is 5–10 times the rated value, suitable for lighting and general electrical appliances.
Разрывная способность10тот (10,000А)10тот (10,000А)Identical; both have high breaking capacity and can safely interrupt short-circuit currents.
Номинальное напряжение230/400V AC (2П)230V AC (1П)2P supports application scenarios with higher voltages.
Installation Space2 модули (36мм)1 module (18мм)2P occupies twice the space of 1P.
  1. Structural and Functional Differences
  2. Pole Number Difference (Most Significant Distinction)

NB1-63H/2PC40: 2-конструкция столба, both poles are equipped with trip units, controlling and protecting both live wire and neutral wire simultaneously.

NXB63H-1P/16A: 1-конструкция столба, only controls the live wire; the neutral wire is connected directly without passing through the circuit breaker.

  1. Protection Scope

Advantages of 2P:

Disconnects both live wire and neutral wire simultaneously to ensure maintenance safety.

Trips when abnormal current is detected in the neutral wire.

Suitable for circuits requiring complete isolation.

Features of 1P:

Compact size, ideal for distribution boxes with limited space.

Lower price for better cost-effectiveness.

Only protects the live wire; the neutral wire may remain energized in case of faults.

  1. Current and Power Carrying Capacity

40А (2П): Suitable for high-power electrical appliances, такой как:

Main kitchen circuits (induction cookers, microwave ovens, и т. д.).

Air conditioners (above 3 Hp.), electric water heaters.

Small commercial electrical equipment.

16А (1П): Suitable for low-power loads, такой как:

Lighting circuits.

Individual standard sockets.

Small household appliances such as televisions and computers.

  1. Application Scenario Comparison

Applicable Scenarios for NB1-63H/2PC40:

  1. Main switches or branch main circuits in residential distribution boxes.
  2. Areas with concentrated electrical appliances such as kitchens and bathrooms.
  3. Dedicated circuits for high-power equipment such as air conditioners and water heaters.
  4. Lighting or small power equipment in commercial premises.
  5. Medical equipment or precision instruments requiring high safety standards.

Applicable Scenarios for NXB63H-1P/16A:

  1. Household lighting circuits.
  2. General socket circuits in individual rooms.
  3. Small office equipment (computers, принтеры, и т. д.).
  4. Low-power electrical appliances such as lamps and fans.
  5. Temporary power supply sites (construction sites, exhibitions, и т. д.).
  6. Рекомендации по выбору
  7. Select Based on Load Power:

Prioritize 16A or higher for loads exceeding 3kW.

Must select 40A or higher for loads exceeding 8kW.

  1. Select Based on Safety Requirements:

Choose 2P for humid environments, areas accessible to personnel, or circuits requiring frequent maintenance.

Choose 1P for basic protection needs with limited space.

  1. Select Based on Distribution Box Space:

Prioritize 1P for tight spaces; standard distribution boxes can accommodate multiple 1P breakers.

Choose 2P for critical circuits or those requiring simultaneous protection of live and neutral wires, trading some space for higher safety.

  1. Summary

The core differences between the two circuit breakers are as follows:

NB1-63H/2PC40: High-end series + 2-pole + large current, suitable for high-power circuits with high safety requirements.

NXB63H-1P/16A: Cost-effective series + 1-pole + small current, suitable for general low-power circuit protection in households.

Selection advice: Make a comprehensive consideration based on circuit load size, safety requirements, and distribution box space. Do not misuse the breakers (например, using 1P for high-power circuits or circuits requiring full protection).

Предыдущий:

Следующий:

Оставить ответ