Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Чинт NM1-800H/3300-800A MCCB - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

Чинт NM1-800H/3300-800A MCCB

CodeЗначение
Нм1Chint NM1 series molded case circuit breaker
800Frame current 800A
ЧАСHigh breaking capacity grade (Grade H, typically 50kA at 400V AC)
33003 столбы, combined tripper (thermomagnetic tripping), no accessories
800АRated current 800A

  • Подробная информация о продукте

Chint NM1-800H/3300-800A is a 3-pole, 800А автоматический выключатель в литом корпусе (MCCB) of the NM1 series, featuring H-grade breaking capacity and thermomagnetic tripping. It is designed for overload and short-circuit protection of power distribution lines, and suitable for industrial and large commercial power distribution trunk lines.

CodeЗначение
Нм1Chint NM1 series molded case circuit breaker
800Frame current 800A
ЧАСHigh breaking capacity grade (Grade H, typically 50kA at 400V AC)
33003 столбы, combined tripper (thermomagnetic tripping), no accessories
800АRated current 800A

Основные параметры

ПараметрЦенить
Rated operating voltage690 В переменного тока, 50Гц
Номинальное напряжение изоляции800В
Номинальный ток800А
Breaking capacityGrade H: 50тот (400В и)
Pole number
Tripper typeThermomagnetic (overload long-time delay + short-circuit instantaneous protection)
Mounting methodFixed type, vertical/horizontal mounting available
Wiring methodFront wiring (rear wiring and plug-in type optional)
Operation methodDirect handle operation
Executive standardГБ 14048.2, МЭК 60947-2, CCC certification

Сценарии применения

Overload and short-circuit protection for industrial power distribution trunks and power circuits in large workshops.

Protection for power distribution main trunks in commercial buildings (shopping malls, офисные здания).

Protection for large motor circuits with infrequent starting.

Installation and Operation Key Points

  1. Installation shall comply with specifications; both vertical and horizontal mounting are acceptable, with secure fastening and good heat dissipation ensured.
  2. Check the specification of wiring terminals before wiring to match cables/bus bars for 800A current.
  3. Regularly inspect the action accuracy of the tripper to avoid the impact of ambient temperature on protection performance.

Cross-brand Replacement Reference

Шнайдер: NSX 800N/3P 800A (Verify breaking capacity and tripping curve).

АББ: Tmax T6N 800/3P 800A (Pay attention to mounting dimensions and accessory compatibility).

The core difference between Chint NM1-800H/3300-800A and NM1-800H/3200-800A lies in the tripper type and protection function; other basic parameters (frame current, breaking capacity, pole number, и т. д.) are completely consistent.

  1. Основное отличие: Meaning of “3300” и “3200” in the Model
Model PartDigital MeaningФункция защиты
33001st digit 3 = 3 столбы; 2nd digit 3 = combined tripper (thermomagnetic tripping); last two digits 00 = no accessoriesOverload long-time delay protection + short-circuit instantaneous protection
32001st digit 3 = 3 столбы; 2nd digit 2 = magnetic tripper (magnetic tripping only); last two digits 00 = no accessoriesShort-circuit instantaneous protection only, no overload protection

This is the fundamental difference between the two circuit breakers, which directly determines their application scenarios and protection capabilities.

  1. Complete Parameter Comparison Table
ПараметрNM1-800H/3300-800ANM1-800H/3200-800AПримечания
Tripper typeThermomagnetic combined trippingMagnetic trippingCore difference
Защита от перегрузки Available (long-time delay)UnavailableА 3300 model achieves overload delay protection through the thermal bending of bimetallic strips
Защита от короткого замыканияAvailable (instantaneous)Available (instantaneous)Both realize short-circuit instantaneous tripping through electromagnetic coils
Frame current800А800АConsistent
Номинальный ток800А800АConsistent
Breaking capacityGrade H (50kA@400V AC)Grade H (50kA@400V AC)Consistent
Pole numberConsistent
Rated voltage690 В переменного тока, 50Гц690 В переменного тока, 50ГцConsistent
Номинальное напряжение изоляции800В800ВConsistent
Mounting methodFixed type (vertical/horizontal)Fixed type (vertical/horizontal)Consistent
Wiring methodFront wiring (rear wiring, plug-in type optional)Front wiring (rear wiring, plug-in type optional)Consistent
Executive standardГБ 14048.2, МЭК 60947-2ГБ 14048.2, МЭК 60947-2Consistent

III. Application Scenario Differences

МодельПрименимые сценарииInapplicable Scenarios
3300• Industrial/commercial power distribution trunks (requiring both overload and short-circuit protection)• Special occasions requiring only short-circuit protection
• Large motor circuits (infrequent starting)• Dedicated circuits for fire-fighting equipment (3300 model with shunt trip is usually required for fire-fighting equipment)
• General lighting and power hybrid distribution systems
3200• Used as an isolating switch (needing short-circuit protection but no overload protection)• Used alone as power distribution line protection (lack of overload protection will cause line overheating and damage)
• Occasions matched with other overload protection devices (например, thermal overload relays)• Direct protection for motors (unable to prevent motor burnout due to overload)
• Special short-circuit protection for specific industrial equipment
  1. Рекомендации по выбору
  2. Prioritize the 3300 model: Most power distribution scenarios require both overload and short-circuit protection; the 3300 model provides more comprehensive protection to avoid line overheating, equipment damage and other problems caused by overload.
  3. Select the 3200 model only under specific conditions: When the system is already equipped with other overload protection devices (например, thermal overload relays, overload alarms), the 3200 model can be used as a dedicated short-circuit protection circuit breaker to reduce costs.
  4. Примечание: А 3200 model cannot be used alone for power distribution lines requiring overload protection due to the lack of overload protection, otherwise potential safety hazards may be caused.