Chint NXB63-C6+AX-X1 circuit breaker - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

Chint NXB63-C6+AX-X1 circuit breaker

The Chint NXB63-C6+AX-X1 circuit breaker is a compact protective device suitable for low-voltage power distribution systems, composed of the NXB63-C6 circuit breaker body and the AX-X1 alarm contact accessory. Below is a detailed analysis of key information: Model Analysis and Core Parameters NXB63-C6 Circuit Breaker BodyKnife Switch Fuse Core RT-3 (NT3) DC440V Series and Function: The NXB-63 ...

  • Подробная информация о продукте

The Chint NXB63-C6+AX-X1 автоматический выключатель is a compact protective device suitable for low-voltage power distribution systems, composed of the NXB63-C6 circuit breaker body and the AX-X1 alarm contact accessory. Below is a detailed analysis of key information:

  1. Model Analysis and Core Parameters
  2. NXB63-C6 Circuit Breaker BodyKnife Switch Fuse Core RT-3 (NT3) DC440V

Series and Function: The NXB-63 is a miniature circuit breaker (МКБ) from Chint’s Kunlun series, suitable for AC circuits with 50Hz/60Hz frequency and a rated voltage of 400VAC, providing overload and short-circuit protection.

Rated Current and Trip Characteristics: C6 indicates a rated current of 6A, with a C-type trip curve (trip current: 5-10 раз номинальный ток), suitable for resistive loads such as lighting and sockets.

Разрывная способность: Standard breaking capacity is 6kA, with some models reaching 10kA (например, NXB-63 2P C10), which should be selected based on the circuit’s short-circuit current. Промежуточное реле Chint JZX-22F/4Z(Д) 24В постоянного тока

Pole Count and Dimensions: Supports multiple pole counts (1П, 2П, 3П), with a width of 18mm per pole, installable on 35mm rails.

  1. AX-X1 Alarm Contact AccessoryЦена тепловых реле перегрузки серии Chint NXR

Функция: When the circuit breaker trips due to overload, short circuit, or other faults, the AX-X1 outputs alarm signals via normally open (НЕТ)/нормально закрытый (Северная Каролина) contacts, which can be connected to monitoring systems or indicator lights. CHINT circuit breaker price

Electrical Parameters: Rated operating voltage covers 115V to 400V (переменный/постоянный ток), with a contact capacity of 3A (AC230V), compatible with various control circuits.

Способ установки: Directly pluggable on the right side of the circuit breaker, removable without tools, and does not affect the main breaker’s function.

  1. Application Scenarios and Selection Recommendations
  2. Типичные применения

Residential and Commercial Power Distribution: Used for lighting circuits (6A loads), small appliance sockets, etc., with AX-X1 for fault warning.

Industrial Control: As branch circuit protection in automated equipment, combined with AX-X1 signals for remote monitoring.

New Energy Fields: Suitable for the output side of photovoltaic inverters (DC compatibility must be confirmed), but models explicitly marked with DC parameters are preferred.

  1. Key Selection Criteria

Текущее соответствие: Select the rated current based on the load current (например, 6A corresponds to ≤1.32kW loads) to avoid false tripping due to overload.

Разрывная способность: Must be greater than the circuit’s expected short-circuit current (например, typically 6kA for residential distribution; 10kA models for high short-circuit risk scenarios like industrial use).

Accessory Compatibility: AX-X1 is only suitable for the NXB-63 series; other series (например, DZ47) require corresponding accessories (например, AX-01).

III. Installation and Usage Precautions

  1. Mechanical Installation

Монтаж на рельсе: The circuit breaker must be vertically installed on a standard 35mm rail, ensuring the卡扣 (clips) are fully engaged to prevent looseness.

Требования к проводке: The incoming end connects to the power supply side, and the outgoing end connects to the load side. The wire cross-sectional area must match the current (1.5mm² is recommended for 6A).

Accessory Installation: AX-X1 should be inserted into the right-side slot with the circuit breaker in the closed state, ensuring contact alignment, and checked for stability after installation.

  1. Electrical Connections

Voltage Matching: The circuit breaker’s rated voltage is 400VAC; it is strictly prohibited for DC systems like DC440V (special DC circuit breakers must be selected for photovoltaic combiner boxes).

Alarm Signal Circuit: AX-X1 contacts must be connected in series to the alarm circuit (например, indicator lights or PLC input modules) to ensure reliable signal transmission.

  1. Условия окружающей среды

Temperature Range: -5°C to 40°C (long-term), with short-term tolerance up to -35°C to 70°C. Derate the current in high-temperature environments (reduce current by 5% for every 10°C increase).

Предел высоты: ≤2000 meters. Special models or derating are required for high-altitude areas (insulation strength decreases by 8% for every 1000 meters increase).

  1. Сертификация и соответствие
  2. Внутренняя сертификация

– Сертифицировано Китайским CCC. (Certificate No. 2020980307001645), compliant with GB 10963.1 стандарты, suitable for the domestic market.

The packaging and product body bear CCC marks, model numbers, rated parameters, etc., which can be verified for authenticity on Chint’s official website.

  1. Адаптация международного рынка

Североамериканский рынок: Not UL-certified; compatible models (например, Siemens 5SJ6 series) or customized versions must be selected.

Европейский рынок: No CE certification; products compliant with EN 60898 стандарты (например, ABB iC65) are recommended.

  1. Maintenance and Fault Handling
  2. Routine Maintenance

Regular Inspections: Check for contact oxidation and loose terminals every 6 months, and clean surface dust.

Function Testing: Simulate overload tripping via the test button annually to verify the circuit breaker’s normal operation.

  1. Fault Troubleshooting

Frequent Tripping: Check if the load exceeds the rated current, if there is a short circuit, or if the circuit breaker is aged and needs replacement.

Abnormal Alarm Signals: Inspect for poor contact in AX-X1 or wiring breaks, and replace the accessory if necessary.

  1. Alternative Solutions and Emergency Procurement
  2. Equivalent Models

Domestic Alternatives: Delixi CDB6-63 C6, Tianzheng TGB1-63 C6 (ensure matching pole count and breaking capacity).

Imported Alternatives: Schneider C65N C6, ABB S201-C6 (note installation dimensions; some are 17.5mm per pole).

  1. Emergency Handling

If AX-X1 is out of stock, temporarily use auxiliary contacts (например, AX-01) as a substitute, but manual reset of alarm signals is required.

In case of circuit breaker body failure, temporarily use a same-specification fuse (например, RT16-3 NT3 6A) as a transition, but replace it as soon as possible.

VII. Procurement and After-Sales Service

  1. Выбор канала

Международный: Procure via agents (WhatsApp: +86-13811255435), and confirm delivery lead times in advance.

  1. Техническая поддержка

Technical hotline (WhatsApp: +86-13811255435) for inquiries on parameter matching and installation guidance.

For bulk purchases, request type test reports (например, short-circuit breaking test data) from suppliers.

Краткое содержание: Procurement Decision Checklist

Inspection ItemCompliance Criteria
Model IdentificationCircuit breaker: NXB63-C6; Accessory: AX-X1, with clear parameters and CCC marks on both body and accessory
Разрывная способность≥ Circuit’s expected short-circuit current (например, 6kA for residential, 10kA for industrial)
Accessory CompatibilityAX-X1 clips match the right-side slot of the circuit breaker, with aligned and secure contacts
Certification MarksОдомашненный: CCC; Export: Additional UL/CE certification required
Packaging and TransportationOriginal factory sealed packaging, shock-proof foam, and logistics providers qualified for electronic component transportation

Благодаря приведенному выше анализу, the NXB63-C6+AX-X1 combination effectively meets the protection and monitoring needs of low-voltage power distribution systems. Strictly verify parameters and certifications during procurement to ensure system reliability.

The Chint NXB63-C6+AX-X1 circuit breaker is a Miniature Circuit Breaker (МКБ) commonly used in low-voltage power distribution systems, providing overload and short-circuit protection. А “+AX-X1likely indicates the inclusion of auxiliary contact (AX) accessories. Below is a general guide to its installation method and precautions (always refer to the product manual for specifics):

  1. Pre-Installation Preparation
  2. Confirm Product Specifications

Ensure the circuit breaker model matches requirements (C6 denotes a rated current of 6A, suitable for low-current circuits like lighting).

The AX-X1 accessory is typically an auxiliary contact for remote signal feedback (например, connecting to alarm or control systems); verify its function and wiring method.

  1. Tools and Materials

Tools needed: Screwdriver ( Phillips or flathead), wire stripper, multimeter, rail installation tool (if required).

Materials: Standard 35mm DIN rail (for mounting the circuit breaker), wires (selected by load current rating).

  1. Safety Power Disconnection

Always disconnect the upstream power supply before installation to ensure the circuit is de-energized and avoid electric shock hazards.

  1. Этапы установки
  2. Монтаж на рельсе (Main Circuit Breaker)

Rail Type: Use a standard 35mm DIN rail (common in distribution panels).

Способ монтажа:

  1. Align the clips at the bottom of the circuit breaker with the rail, press down firmly until aclickis heard to confirm secure attachment.
  2. To remove, use a screwdriver or specialized tool to press the clip on the side of the circuit breaker and pull upward.
  3. Accessory Installation (AX-X1 Auxiliary Contact)

Installation Location: Auxiliary contacts are typically mounted on the right side of the main circuit breaker (some models may support left or rear mounting; refer to the manual).

Способ монтажа:

  1. Align the卡槽 (slots) of the auxiliary contact with the interface of the main circuit breaker, push horizontally to fix (may require screws or clips for locking).
  2. Ensure the accessory is tightly connected to the main circuit breaker without looseness.
  3. Wiring Operations

Main Circuit Wiring (Circuit Breaker Body):

Incoming Terminals (Top): Connect to the power supply side (usually live wire L and neutral wire N; note that the neutral wire may need to be connected via a terminal block, depending on whether the circuit breaker has a neutral terminal).

Outgoing Terminals (Bottom): Connect to the load side (например, lamps, розетки).

Меры предосторожности:

Wire cross-sectional area should match the current (1.5mm² or 2.5mm² copper wire is recommended for 6A current).

Strip wires to an appropriate length to avoid short circuits; ensure terminal screws are tightened securely.

Accessory Wiring (AX-X1 Auxiliary Contact):

Auxiliary contacts typically have 2-4 терминалы (например, NO normally open, NC normally closed) for connecting control circuits (например, to energy meters, alarm systems, or PLCs).

Connect wires to the corresponding terminals as needed (marked such as “1-2” for normally open, “3-4” for normally closed), and tighten the screws.

III. Post-Installation Inspection and Testing

  1. Visual Inspection

Confirm the circuit breaker and accessories are firmly installed without tilting or looseness; ensure no exposed copper wires and tight terminal screws.

  1. Function Testing

Close the upstream power supply and check if the circuit breaker indicator (if available) is normal.

Manually switch the circuit breaker on and off to test smooth operation and whether auxiliary contacts actuate synchronously (use a multimeter to measure contact continuity).

Simulate overload or short-circuit conditions (exercise caution) to test if the circuit breaker trips promptly for protection.

  1. Safety Verification

Use a multimeter to measure line insulation resistance to ensure no grounding or short-circuit faults.

Check that the distribution panel is reliably grounded and complies with electrical installation codes.

  1. Меры предосторожности
  2. Polarity and Neutral Handling

Single-pole circuit breakers (1П) usually connect only the live wire; the neutral wire must be connected via the distribution panel’s neutral terminal block. For 1P+N circuit breakers, distinguish the incoming direction of the live wire (л) и нейтральный провод (Н) (the N terminal is typically a fixed hole and not interruptible).

  1. Экологические требования

Install in dry, ventilated areas free of corrosive gases, avoiding high-temperature or humid environments.

Leave sufficient space in the distribution panel to ensure good heat dissipation.

  1. Профессиональная эксплуатация

If unfamiliar with electrical installation, consult a licensed electrician to ensure compliance with local electrical codes (например, China’s GB standards).

We hope this information helps! Always prioritize safety and follow proper procedures during installation.