Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Delta VFD055C43A-21-5.5kW Vector Control Inverter - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

солнечный инвертор/электрический/

Delta VFD055C43A-21-5.5kW Vector Control Inverter

БрендМодельРяд
Сименс6SL3210-1KE21-3UF1 (G120C ПН)SINAMICS G120C
MitsubishiFR-A840-00720-2-60FREQROL A840
YaskawaCIMR-AB4A0018FBAA1000
ШнайдерATV320U75N4Altivar 320
АББACS550-01-012A-4ACS550

  • Подробная информация о продукте

 

Model PartЗначениеПодробное объяснение
VFDDelta Inverter IdentifierAbbreviation for Variable Frequency Drive, the universal prefix for Delta’s industrial automation inverters.
55Применимая мощность двигателяFor 5.5kW (7.5HP) motors; this is the rated output power of the drive.
СSeries CodeC2000/C2000+ Series – Delta high-performance general-purpose vector inverter, supporting induction motors and permanent magnet synchronous motors.
43Voltage Class & Phase4 = 3-phase 400V class (380~480V); 3 = 3-phase input (vs. 1 for single-phase).
АControl Mode & ФункцииSupports Vector Control (FOC), Контроль крутящего момента (TRQ), high-performance algorithm, 200% starting torque at 0.5Hz.
-21Version & ConfigurationStandard version: built-in braking unit (selected power ratings), no built-in EMC filter (external available), compliant with international standards.
  1. Core Technical Specifications (Official 2026 Data)
КатегорияЭлементЦенитьПримечания
Basic SpecsRated Power5.5кВт (7.5HP)For 5.5kW 3-phase induction motors
Input Voltage3-phase 380~480V (+10%/-20%)47~63Hz, wide voltage range
Rated Output Current12А (heavy duty) / 10.8А (light duty)Continuous operation in heavy-duty mode
Output Frequency Range0.1~600HzFor both low‑ and high‑speed applications
Control PerformanceControl ModeSensorless Vector, Closed-loop Vector, V/F ControlSwitchable closed/open loop
Starting Torque200% rated torque at 0.5HzIdeal for heavy starting loads
Перегрузочная способность150% for 60s; 200% for 3sFor shock loads
Speed Accuracy±0.5% (open-loop) / ±0.02% (closed-loop)High precision speed control
Torque Response Time≤10msFast dynamic response
Аппаратное обеспечениеСтепень защитыIP20 (cabinet mount)Finger‑safe; clean environment recommended
CoolingForced air (removable fan)Easy maintenance, long service life
Built-in FunctionsBraking unit (≤7.5kW), ПЛК (5,000 steps)High integration, fewer external parts
CommunicationRS-485 (Modbus RTU) стандартныйPROFINET/EtherNet/IP/CANopen optional
СредаOperating Temp-10~40°C (derate 40~50°C)Derate 1% per °C above 40°C
Storage Temp-20~60°CAvoid moisture & corrosive gas
Влажность5~95% (non‑condensing)Suitable for industrial environments

III. Core Features & Преимущества

3.1 High‑Performance Control

Vector control: Precise independent torque & speed control for complex loads.

Built-in PLC: 5,000-step logic programming for simple automation, reducing external PLC dependency.

Auto energy saving: Dynamically adjusts output voltage; saves 20~50% at light load.

Motor auto-tuning: Completes matching in <10с, simplifies commissioning.

3.2 High Reliability Design

Modular structure: Hot-swappable keypad, expandable I/O and communication cards for easy maintenance.

Full protection: Перегрузка по току, перенапряжение, пониженное напряжение, overheat, overload, потеря фазы, замыкание на землю, и т. д..

Safe stop: Supports STO (Safe Torque Off), SIL 2 certified.

Wide grid tolerance: Withstands ±15% voltage fluctuation for harsh grids.

3.3 Flexible Communication & Расширение

Standard RS-485 Modbus RTU for multi-drive network control.

Optional modules: ПРОФИНЕТ, EtherNet/IP, ПРОФИБУС ДП, CANopen.

Compatible with Siemens, Mitsubishi, Rockwell PLCs via standard telegrams and process objects.

Remote monitoring & diagnostics via Delta DIAStudio or TIA Portal.

  1. Applications & Selection Tips

4.1 Recommended Applications

IndustryТипичные примененияФункции
General MachineryPumps, фанаты, компрессоры, mixersEnergy saving, stable operation, longer equipment life
Material HandlingКонвейеры, краны, hoists, packaging machinesHigh precision speed control, heavy start, quick stop
Metal ProcessingLathes, milling, grinding, punching machinesHigh response, precise positioning, torque control
Textile & DyeingTextile machines, dyeing machines, stenter framesConstant tension, synchronous operation, wide speed range
Plastic & RubberInjection molding, extrusion, blow moldingSignificant energy saving (20~60%), stable pressure control

4.2 Selection Key Points

  1. Power matching: Use VFD055C43A-21 for 5.5kW motors; avoid undersizing.
  2. Load type:

Constant torque (конвейеры, mixers): use heavy-duty mode (12А).

Variable torque (фанаты, насосы): light-duty mode (10.8А) for better efficiency.

  1. Control requirements:

High-precision positioning: use encoder (PG card) closed-loop vector.

Network control: add communication module (например, ПРОФИНЕТ).

  1. Среда:

High temperature: extra cooling or derating required.

Dusty environment: dust cover + regular fan cleaning.

  1. Replacement Models & Upgrade Path

5.3 Upgrade Suggestions

  1. Basic upgrade: VFD‑M/GD10 → C2000+ for better precision & функции.
  2. Communication upgrade: Add PROFINET card for Industry 4.0 connectivity.
  3. System upgrade: Combine with Delta PLC (DVP series) & HMI for full automation solution.

Buying Notes

  1. Confirm suffix -21 (стандартная версия), avoid old versions (например, -00).
  2. Verify power & current: 5.5kW → 12A rated.
  3. Buy from authorized Delta channels for genuine product & service.
  4. Order accessories as needed: communication card, keypad, braking resistor.

VII. Установка & Maintenance

7.1 Installation Rules

  1. Монтаж: Wall/cabinet mount, вертикальная установка; ≥150mm clearance top & bottom for ventilation.
  2. Электропроводка:

Separate power & control cables to avoid interference.

Shielded cable for signals, single‑end grounding.

Braking resistor matched to power (≤7.5kW internal; external ≈100Ω/500W).

  1. Grounding: Ground resistance ≤4Ω for safety & noise immunity.

Delta VFD055C43A-21 is a high‑performance 5.5kW vector inverter from the C2000+ series, featuring high precision, reliability, and expandability for diverse industrial applications. With built-in PLC, wide voltage tolerance, and complete protection, it is an excellent choice for general industrial drive solutions. Select based on motor power, load type, control requirements, and environment for optimal performance and cost-effectiveness.

Complete Replacement Guide for Delta VFD055C43A-21

  1. Delta Internal Replacements (C2000+ Series, Seamless Compatibility)

1.1 Direct Same‑Series Replacements

Fault CodeCauseSolution
OCПерегрузка по токуCheck motor short, overload, acceleration time
OVOvervoltageCheck mains voltage, deceleration time, braking resistor
UVПониженное напряжениеCheck input phase, Напряжение, cable size
OHOverheatCheck fan, ventilation, ambient temperature
PHPhase lossCheck input/output wiring, motor winding

1.2 Near‑Power Replacements

МодельВластьНоминальный токKey FeaturesПриложение
VFD055C43A-21 (Original)5.5кВт12А / 10.8АC2000+, vector, built-in brake, RS-485General industry
VFD055C43A-21 (Upgraded)5.5кВт12АBetter cooling, 10,000-step PLC, more protocolsNew projects
VFD055CH43A-215.5кВт12АCH2000, fan/pump specializedFans, насосы
VFD055CP43B-215.5кВт12АCP2000, hoist/crane dedicatedCranes, hoists
  1. Global Brand Replacements (5.5кВт / 400V Vector)

2.1 Premium Brands

БрендМодельРядControlAdvantage
Сименс6SL3210-1KE21-3UF1 (G120C ПН)SINAMICS G120CVector/V/FПРОФИНЕТ, EMC filter
MitsubishiFR-A840-00720-2-60FREQROL A840VectorHigh response, built-in PLC
YaskawaCIMR-AB4A0018FBAA1000VectorLow noise, stable
ШнайдерATV320U75N4Altivar 320Vector/V/FКомпактный, multi-protocol
АББACS550-01-012A-4ACS550DTCHigh torque accuracy

2.2 Cost‑Effective Brands

БрендМодельРядControlAdvantage
InovanceMD280NT5.5GBMD280VectorPROFINET supported
VeichiAC70-T3-055GAC70VectorFull-featured, low cost
INVTCHF100A-5R5G/7R5P-4CHF100AVectorBuilt-in brake un

III. Critical Replacement Rules (Must Follow)

  1. Власть & current: Rated power ≥5.5kW, current ≥12A (heavy duty).
  2. Напряжение: 400V class (380~480V) only; do NOT use 200V directly.
  3. Control: Prefer vector control for matching dynamics.
  4. Перегрузка: At least 150% for 60s.
  5. Communication: RS-485 standard; PROFINET/EtherNet/IP optional.

Mechanical Compatibility

Размеры: ~90×180×150mm – use same or smaller size.

Cooling: Forced air – keep airflow direction.

Brake unit: Internal for ≤7.5kW; match external if needed.

Keypad: Use Delta standard keypad or compatible.

Best Replacement by Application

Общая техника: VFD055C43A-21 upgraded or Siemens G120C PN.

Fans & насосы: VFD055CH43A-21 or Schneider ATV320U75N4.

Cranes/hoists: VFD055CP43B-21 or Mitsubishi FR-A840.

Budget projects: Inovance MD280NT5.5GB or Veichi AC70-T3-055G.

  1. Upgrade Paths

4.1 Delta Internal Upgrade

  1. C2000 → C2000+ (performance & function improvement).
  2. Add PROFINET module (VFD-CM-PN01) for industrial networking.
  3. Pair with Delta PLC + HMI for full automation system.

4.2 Cross‑Brand Upgrade

  1. Communication: RS-485 → PROFINET / EtherNet/IP.
  2. Control: Open-loop vector → closed-loop vector with encoder.
  3. Безопасность: Choose models with STO (SIL 2).

The Delta VFD055C43A-21 has a wide range of replacements.

Same‑brand (C2000+ upgraded) offers seamless compatibility.

Cross‑brand (Siemens G120C PN, Mitsubishi FR-A840) provides higher performance.

Always follow core parameter matching to ensure stable, reliable replacement without performance loss or equipment damage.

Предыдущий:

Оставить ответ

Оставить сообщение