Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

GV3P80 Motor Circuit Breaker - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

GV3P80 Motor Circuit Breaker

GV3P80 is a 3‑pole thermal‑magnetic motor circuit breaker from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400В) / 55кВт (690В) three‑phase motors. It integrates triple protection (перегрузка, short‑circuit, phase failure) and isolation function, serving as a core protection component in industrial motor circuits. Model Explanation GV3: ...

  • Подробная информация о продукте

GV3P80 is a 3‑pole thermal‑magnetic motor circuit breaker from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400В) / 55кВт (690В) three‑phase motors. It integrates triple protection (перегрузка, short‑circuit, phase failure) and isolation function, serving as a core protection component in industrial motor circuits.

  1. Модель Объяснение

GV3: TeSys GV3 motor circuit breaker series (frame size 3)

П: Thermal‑magnetic release (triple protection: перегрузка + short‑circuit + phase failure)

80: Rated current 80A, adjustable range 70–80A (continuously adjustable)

  1. Key Specifications (Full Data)
ЭлементСпецификация
поляки3П (three‑phase)
Adjustment current range70–80A (continuously adjustable)
Тип поездкиТермомагнитный
Short‑circuit trip multiplier14×In (1120А)
Breaking capacity Icu65kA @ 230V; 50kA @ 400V; 6kA @ 690V
Номинальное рабочее напряжение Ue690В переменного тока 50/60 Гц
Insulation voltage Ui690В и
Impulse withstand voltage Uimp6кВ
Подходящая мощность двигателя45kW @ 400V; 55kW @ 690V; 22kW @ 230V
ТерминалыEverLink screw terminals (25–35mm² cable)
МонтажDIN-рейка (width 55mm), screw mountable
Degree of protectionIP20 (front)
Рабочая температура-20°C ~ +60°C (derating factor: 0.8 at +60°C)
Механическая выносливость50,000 operating cycles
Электрическая выносливость20,000 циклы (category AC‑3)
Функция изоляцииComplies with IEC 60947‑1, can be used as safety isolator
СертификатыCCC, CE, UL, CSA, IEC 60947‑4‑1
МассаПриблизительно. 1.02 кг
Размеры (Ш×В×Г)55 × 105 × 78 мм
  1. Основные функции & Преимущества
  2. Triple Protection

Thermal trip: Overload inverse‑time protection (simulates motor heating characteristics)

Magnetic trip: Short‑circuit instantaneous protection (fixed 14×In)

Защита от обрыва фазы: Automatic trip under three‑phase unbalance (IEC 60947‑4‑1)

  1. EverLink Terminal Technology

Maintenance‑free, anti‑loosening, oxidation‑resistant, suitable for large‑section cables, reduces wiring failure risks.

  1. Safety Design

Knob operation, lockable in OFF position (до 3 padlocks)

Clear current scale for precise adjustment

Complies with IEC isolation standards, usable as motor circuit isolator

  1. Wide Environmental Adaptability

Operating altitude: ≤3000m (no derating required)

Vibration resistance: 10–150Hz, 0.5mm amplitude

Shock resistance: 5Gn (11РС); 30Gn (1РС)

  1. Справочник по выбору (TeSys GV3 Series)
МодельAdjustment CurrentSuitable Power (400В)Trip TypeФункции
GV3P6555–65A37кВтТермомагнитныйСтандартный, EverLink terminals
GV3P8070–80A45кВтТермомагнитныйThis model, max adjustment current
GV3L8070–80A45кВтMagneticShort‑circuit protection only
GV3ME8040–80A45кВтТермомагнитный3‑step adjustment (40–50/63–80), economy version
GV3P4030–40A22кВтТермомагнитныйFor small‑medium motors
  1. Приложения

Прямой запуск / star‑delta starting circuits for three‑phase asynchronous motors

Main circuit protection for fans, насосы, компрессоры, конвейеры, machine tools

Industrial automation lines, construction equipment motor control

Motor circuits requiring isolation and safety interlock (например, emergency stop loops)

Motors with frequent starting/stopping and fluctuating loads

  1. Replacement Options
  2. Schneider same series

GV3L80 (short‑circuit only, lower cost)

GV3ME80 (simplified adjustment, same mounting space)

  1. Competitor alternatives

Сименс: 3RV1041‑4JA10 (70–80A, 3П, термомагнитный)

АББ: MS165‑80 (70–80A, 3П, термомагнитный)

Chinese brands: Chint NM1‑125S, Delixi CDM1‑125 (motor protection curve matching required)

  1. Upgrade solution

Schneider GV4P08N (frame 4, higher breaking capacity, for motors above 55kW)

Selection Tips

  1. Select adjustment range at 1.1–1.25 × motor rated current
  2. Confirm breaking capacity meets system short‑circuit current requirements
  3. For isolation function, prefer models with certified isolation
  4. For limited wiring space, choose EverLink terminal models to reduce faults

Complete Model List of Schneider Electric TeSys GV Series Motor Circuit Breakers

Schneider TeSys GV series motor circuit breakers include six sub‑series: GV1, GV2, GV3, GV4, GV5, GV6, covering an adjustment range from 0.06A to 800A, suitable for 0.03kW to 400kW (400В) three‑phase motors, with thermal‑magnetic, magnetic, and economy thermal‑magnetic protection types.

  1. GV1 Series (Miniature, прекращено, replaced by GV2ME)

GV1ME01: 0.1–0,16А

GV1ME02: 0.16–0.25A

GV1ME03: 0.25–0.4A

GV1ME04: 0.4–0.63A

GV1ME05: 0.63–1.0A

GV1ME06: 1.0–1.6A

GV1ME07: 1.6–2.5A

GV1ME08: 2.5–4.0A

  1. GV2 Series (Маленький, 0.06–16A, 0.03–15kW/400V)

2.1 GV2P (Термомагнитный, полная защита, knob)

МодельAdjustment CurrentSuitable Power (400В)
GV2P010.1–0,16А0.06кВт
GV2P020.16–0.25A0.12кВт
GV2P030.25–0.4A0.2кВт
GV2P040.4–0.63A0.37кВт
GV2P050.63–1.0A0.55кВт
GV2P061.0–1.6A0.75кВт
GV2P071.6–2.5A1.5кВт
GV2P082.5–4.0A2.2кВт
GV2P104.0–6.3A3кВт
GV2P146.3–10A4кВт
GV2P1610–16A7.5кВт

2.2 GV2L (Magnetic, short‑circuit only, knob)

МодельAdjustment CurrentSuitable Power (400В)
GV2L010.1–0,16А0.06кВт
GV2L020.16–0.25A0.12кВт
GV2L030.25–0.4A0.2кВт
GV2L040.4–0.63A0.37кВт
GV2L050.63–1.0A0.55кВт
GV2L061.0–1.6A0.75кВт
GV2L071.6–2.5A1.5кВт
GV2L082.5–4.0A2.2кВт
GV2L104.0–6.3A3кВт
GV2L146.3–10A4кВт
GV2L1610–16A7.5кВт
GV2L2014–20А11кВт
GV2L2218–25A15кВт

2.3 GV2ME (Economy thermal‑magnetic, pushbutton, 3‑step)

МодельAdjustment CurrentSuitable Power (400В)
GV2ME010.1–0,16А0.06кВт
GV2ME020.16–0.25A0.12кВт
GV2ME030.25–0.4A0.2кВт
GV2ME040.4–0.63A0.37кВт
GV2ME050.63–1.0A0.55кВт
GV2ME061.0–1.6A0.75кВт
GV2ME071.6–2.5A1.5кВт
GV2ME082.5–4.0A2.2кВт
GV2ME104–6.3A3кВт
GV2ME146.3–10A4кВт
GV2ME1610–16A7.5кВт

2.4 GV2LE (Magnetic with electronic trip, special applications)

GV2LE01 ~ GV2LE22: matching current ratings as GV2L, with electronic trip

  1. GV3 Series (Середина, 9–80A, 5.5–45kW/400V, 55mm width)

3.1 GV3P (Термомагнитный, полная защита, EverLink)

МодельAdjustment CurrentSuitable Power (400В)
GV3P139–13A5.5кВт
GV3P1813–18A11кВт
GV3P2518–25A15кВт
GV3P3223–32A18.5кВт
GV3P4030–40A22кВт
GV3P5040–50A30кВт
GV3P6555–65A37кВт
GV3P7365–73A45кВт
GV3P8070–80A45кВт

3.2 GV3L (Magnetic, short‑circuit only)

GV3L25: 18–25A

GV3L32: 23–32A

GV3L40: 30–40A

GV3L50: 40–50A

GV3L65: 55–65A

GV3L80: 70–80A

3.3 GV3ME (Economy thermal‑magnetic, 3‑step)

МодельAdjustment CurrentSuitable Power (400В)
GV3ME4040–50A30кВт
GV3ME6350-63А37кВт
GV3ME8040–80A (3 steps: 40–50/63–80)45кВт
  1. GV4 Series (Большой, 25–115A, 15–55kW/400V, 81mm width)

4.1 GV4P (Термомагнитный, полная защита)

МодельAdjustment CurrentSuitable Power (400В)
GV4P2525–32A18.5кВт
GV4P4032–40A22кВт
GV4P5040–50A30кВт
GV4P6350-63А37кВт
GV4P8063–80A45кВт
GV4P10080–100A55кВт
GV4P115100–115A55кВт

4.2 GV4L / GV4LE (Magnetic type)

GV4L25 ~ GV4L115: matching current ratings as GV4P

GV4LE25 ~ GV4LE115: magnetic with electronic trip

4.3 Special GV4 Models

GV4PB80S: UL489 approved, 63–80A

GV4P02N: 2‑pole thermal‑magnetic, special applications

  1. GV5 / GV6 Series (Extra‑large, 100–800A, 55–400kW/400V)

GV5P100: 80–100A

GV5P125: 100–125A

GV5P160: 125–160A

GV5P200: 160–200A

GV6P250: 200–250A

GV6P315: 250–315A

GV6P400: 315–400A

GV6P500: 400–500A

GV6P630: 500–630A

GV6P800: 630–800A

 

  1. Правила именования моделей
Letter/NumberЗначение
GVTeSys GV series motor circuit breaker
1/2/3/4/5/6Frame size (1 = smallest, 6 = largest)
ПThermal‑magnetic trip (перегрузка + short‑circuit + phase failure)
лMagnetic trip (short‑circuit only)
MEEconomy thermal‑magnetic trip (3‑step, cost‑optimized)
ТОMagnetic trip with electronic functions
NumberТекущий рейтинг (например, 80 = 70–80A)
  1. Quick Selection Guide
  2. Select adjustment range at 1.1–1.25 × motor rated current
  3. For full protection (перегрузка + short‑circuit + phase failure): choose P series
  4. If thermal protection exists (например, VFD): choose L series (short‑circuit only)
  5. Cost‑sensitive, simple adjustment: choose ME series (3‑step)
  6. Small motors (≤15kW): GV2; середина (15–45kW): GV3; большой (≥55kW): GV4–GV6
  7. Примечания
  8. All models are 3‑pole (3П) for three‑phase asynchronous motors
  9. Protection characteristics comply with IEC 60947‑4‑1
  10. Отключающая способность: GV2/GV3 100kA@400V; GV4 65kA@400V
  11. Монтаж: 35мм стандартная DIN-рейка
  12. Degree of protection: IP20 (front operating part)