Schneider Acti9 Series A9I48191V120H1P-100A

ЭлементSpecification Parameter
Brand and SeriesSchneider Acti9 Series
Тип продукта1-pole Disconnector (speculative)
Rated Working Voltage120В и (North American voltage class)
Rated Working Current100А
Номер полюса1-столб
Core FunctionCircuit isolation, no-load switching
Application ScenarioPower isolation and maintenance power-off in single-phase 120V power distribution systems in North America

  • Подробная информация о продукте

Model A9I48191V120H1P-100A

Model A9I48191V120H1P-100A is the complete order number of a low-voltage electrical product under the Acti9 Series of Schneider Electric. The meaning of each segment of the code and the corresponding product attributes can be explained as follows:

  1. Model Segment Analysis
  2. A9: Represents the major product series, namely Schneider’s Acti9 Series. This series is a standardized low-voltage component series launched by Schneider for terminal power distribution, covering miniature circuit breakers, residual current devices, disconnectors, and other products.
  3. I48: Represents the product type sub-code. In combination with the naming rules of the Acti9 Series, this code usually refers to disconnectors or fuse-disconnectors, which are mainly designed for no-load switching of circuits and power isolation.
  4. 191: Represents the structural characteristics and accessory configuration code. Different number combinations correspond to different installation methods (например, DIN rail mounting), operation methods (например, handle operation), or auxiliary contact configurations.
  5. V120: Represents the rated working voltage parameter of the product. Here, `V120` indicates that the rated working voltage of the product is suitable for 120V AC circuits. It should be noted that this voltage class is common in the North American market and is incompatible with the mainstream 220V/380V voltage system in China.
  6. H1P: Represents the pole number and installation specification of the product. `H1P` means a 1-pole product, suitable for the isolation requirements of single-phase circuits.
  7. 100А: Represents the rated working current of the product, то есть, the maximum current that the component can carry stably for a long time is 100A.
  8. Summary of Core Product Attributes
ЭлементSpecification Parameter
Brand and SeriesSchneider Acti9 Series
Тип продукта1-pole Disconnector (speculative)
Rated Working Voltage120В и (North American voltage class)
Rated Working Current100А
Номер полюса1-столб
Core FunctionCircuit isolation, no-load switching
Application ScenarioPower isolation and maintenance power-off in single-phase 120V power distribution systems in North America
  1. Key Precautions
  2. Voltage Compatibility: The rated voltage of this product is 120V AC. It is strictly prohibited to use it directly in domestic 220V AC circuits, в противном случае, it may cause safety accidents such as component burnout and insulation breakdown.
  3. Functional Positioning: Disconnectors do not have short-circuit protection or overload protection functions and are only used for circuit isolation. They must be used in conjunction with protective components such as circuit breakers.
  4. Model Verification: To confirm accurate product drawings, installation dimensions, and technical manuals, you can enter the complete order number through Schneider’s official product selection tool or technical support hotline for inquiry.

Domestic Voltage-Adaptable Model Comparison Table for Schneider Acti9 Series 100A Disconnectors

The following is a complete comparison table of domestic adaptable models corresponding to the North American model A9I48191V120H1P-100A and models with different pole numbers of the same specification. These models are suitable for the mainstream 230/400V AC voltage system in China and meet the isolation requirements of single-phase/three-phase power distribution systems.

  1. Core Model Correspondence
North American Original ModelDomestic Adaptable ModelProduct SeriesНомер полюсаНоминальное напряжениеНоминальный токТип продукта
A9I48191V120H1P-100AA9S70690 (iSW Series) / A9S66191Acti9230/400В и100АMiniature Disconnector
A9I48191V120H1P-100AA9S71690 (iSW Series)Acti9230/400В и100АDisconnector with Auxiliary Contacts
A9I48191V120H1P-100AiINT125 1P 100AActi9230/400В и100АTerminal Disconnector
  1. Complete Table of Domestic Adaptable Models with Different Pole Numbers of the Same Specification
Номер полюсаDomestic Standard ModelProduct SeriesНоминальное напряжениеНоминальный токModule WidthCore FeaturesТипичные сценарии применения
A9S70690 (iSW)Acti9230/400В и100А2 модули (18мм)Basic disconnector without auxiliary contactsIsolation of single-phase circuits, such as residential incoming lines and power isolation of small equipment
A9S66191 (iSW)Acti9230/400В и100А2 модули (18мм)Standard disconnector with red operating handleSingle-phase power distribution in commercial buildings, maintenance isolation
iINT125 1P 100AActi9230/400В и100А2 модули (18мм)Terminal-specific with optimized operating mechanismDC-side isolation of photovoltaic systems, front-end of small UPS
A9S70790 (iSW)Acti9230/400В и100А4 модули (36мм)2-pole interlock, simultaneous isolation of live wire and neutral wireSingle-phase 2-pole circuits, such as high-power household appliances like air conditioners and water heaters
A9S66291 (iSW)Acti9230/400В и100А4 модули (36мм)Standard 2-pole with red handlePower isolation of commercial kitchen equipment and small air compressors
A9S70890 (iSW)Acti9400В и100А6 модули (54мм)3-pole interlock, three-phase isolationFront-end of three-phase equipment such as motors, водяные насосы, и фанаты
A9S66391 (iSW)Acti9400В и100А6 модули (54мм)Standard 3-pole with high short-circuit withstand capacityIndustrial automation equipment, main switch of small power distribution cabinets
A9S70990 (iSW)Acti9400В и100А8 модули (72мм)4-pole interlock, three-phase + neutral wire isolationUPS input/output in data centers, isolation of medical equipment
A9S66491 (iSW)Acti9400В и100А8 модули (72мм)Standard 4-pole with locking deviceThree-phase power distribution in special industries such as chemical and metallurgical industries
  1. Key Adaptation Instructions
  2. Voltage Compatibility: All domestic models are suitable for 230/400V AC (50/60Гц), fully compatible with the domestic power grid. It is strictly prohibited to directly use North American 120V models in domestic 220V/380V systems.
  3. Functional Consistency: All domestic models retain the core functions of disconnectors—no-load circuit switching and power isolation. They do not have short-circuit or overload protection capabilities and must be used in conjunction with circuit breakers.
  4. Installation Compatibility: All models adopt 35mm DIN standard rail mounting, consistent with the installation method of the original North American model, enabling direct replacement and installation.
  5. Рекомендации по выбору:

For single-phase circuits, prioritize 1P/2P models.

For three-phase power circuits, prioritize 3P models.

For critical loads requiring simultaneous neutral wire isolation (such as medical equipment and data centers), select 4P models.

For applications requiring remote status monitoring, select models with auxiliary contacts such as A9S71690.

  1. Supplementary Information
ЭлементDetailed Description
Certification StandardСоответствует МЭК 60947-3 and GB 14048.3 стандарты, holding domestic CCC certification
Operating LifeMechanical life ≥ 10,000 раз; Electrical life ≥ 1,000 раз (работа без нагрузки)
TerminalSuitable for 16~25mm² copper conductors, recommended torque: 8~10N·m
Класс защитыIP20, suitable for installation inside power distribution cabinets