Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Schneider EA9AN4C63 Miniature Circuit Breaker - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

Schneider EA9AN4C63 Miniature Circuit Breaker

БрендЗапасная модель
АББS204‑C63
Сименс5SY6463‑7CC
CHINTNXB‑63 4P C63
ВкусныйCDM30s‑63 4P C63
Schneider upgradeA9F94463 (Acti9 series)

  • Подробная информация о продукте

Schneider Easy9 series 4‑pole 63A C‑curve миниатюрный автоматический выключатель, used for overload and short‑circuit protection in three‑phase four‑wire distribution systems. DIN‑rail mountable, suitable for final distribution in residential, commercial and light industrial applications.

1 Model Explanation

PartЗначение
EA9ANEasy9 series standard MCB
44 столбы (3 phases + Н), all poles with protection function
СC tripping curve (5–10In instantaneous trip), suitable for lighting and resistive/slightly inductive mixed loads
63Rated current 63A (at 30°C ambient)

2 Ключевые технические параметры

ПараметрЦенитьОписание
Rated operational voltage230/400В иSuitable for single‑/three‑phase systems
Номинальное напряжение изоляции400В и
Rated frequency50/60ГцUniversal frequency
Rated breaking capacity6тот (400V.)Standard breaking capacity for general distribution
Tripping typeThermal‑magneticThermal overload protection + magnetic short‑circuit protection
Tripping curveC‑curveInstantaneous trip range: 5–10В, moderate inrush current withstand
Number of poles4 protected poles, neutral on the left
Mounting35мм DIN-рейкаStandard electrical cabinet mounting
Electrical endurance10,000 операцииRated operating cycles
Mechanical endurance20,000 операцииMechanical operating cycles
РазмерыПриблизительно. 85mm×78.5mm×18mm (4‑pole width)Standard 4‑pole MCB size
StandardsGB16917/IEC60898National and international standards

3 Основные функции & Функции

  1. Защита от перегрузки: Thermal trip unit acts with current‑time accumulation to prevent overheating and burnout.
  2. Short‑circuit protection: Magnetic trip unit operates instantaneously (<0.1с) to clear short‑circuit current and protect equipment and wiring.
  3. Функция изоляции: Complies with EN/IEC 60947‑2, can be used as an isolating device.
  4. Quick make: Internal mechanism ensures fast circuit closing.
  5. Operation indication: Clear ON/OFF status indication for easy maintenance.
  6. Safety design: Anti‑misoperation structure, high insulation performance, safe and reliable.

4 Типичные применения

Residential distribution: Main incoming breaker for three‑phase four‑wire homes, protecting the entire electrical system.

Commercial buildings: Floor or zone main breaker in offices, shopping malls, hotels, и т. д..

Light industry: Branch circuit protection for workshops and production lines, suitable for mixed motor, lighting and socket loads.

Final distribution: Dedicated protection for three‑phase equipment (кондиционеры, насосы, small machine tools).

5 Cross‑Brand Replacement Reference

БрендЗапасная модельПримечания
АББS204‑C63Same 4P C63A, 6kA breaking capacity
Сименс5SY6463‑7CC4P C63A, standard breaking capacity
CHINTNXB‑63 4P C63Domestic alternative, cost‑effective
ВкусныйCDM30s‑63 4P C63Similar performance, compatible with domestic panels
Schneider upgradeA9F94463 (Acti9 series)Breaking capacity up to 15kA, improved performance

6 Установка & Selection Notes

  1. Installation precautions

Must be mounted on 35mm standard DIN rail, installation depth ≥78.5mm

Terminal suitable for copper conductors: 1.5–35mm²

Neutral must be connected to the designated left terminal – do not reverse.

  1. Selection recommendations

Total three‑phase load current ≤63A, suitable for C‑curve loads (not heavy motor starting).

For distribution systems with short‑circuit current >6тот, upgrade to higher breaking capacity models (например, Acti9 series).

Derate at ambient temperature >30°C: current reduced by 1% per °C rise.

Schneider EA9AN4C63 vs Acti9 A9F94463 Full Comparison & Upgrade Recommendation

At a glance: A9F94463 (iC60L series) is superior to EA9AN4C63 in breaking capacity, compactness, accessory expandability, and electrical/mechanical endurance, suitable for higher short‑circuit risk and higher reliability/expandability requirements.

EA9AN4C63 is more economical and meets basic protection for standard residential and light commercial use.

1 Сравнение основных параметров

ПараметрEA9AN4C63 (Easy9)A9F94463 (Acti9 iC60L)Key Difference
Series positioningEconomic standardHigh‑performance standardA9 higher‑end, richer functions
Poles/Current/Curve4П / 63А / C‑curve4П / 63А / C‑curveBasic specs identical
Rated breaking capacity6тот (400V.)15тот (400V.)A9 ×2.5 higher, stronger short‑circuit withstand
Номинальное напряжение изоляции400В и400В иSame
Rated operational voltage230/400В и230/400В иSame
Tripping typeThermal‑magneticThermal‑magneticSame
Mounting35мм DIN-рейка35мм DIN-рейкаSame
Размеры85mm×78.5mm×18mm (4П)85mm×44.5mm×18mm (4П)A9 depth –43%, saves panel space
Wiring capacity1.5–35mm² (copper)1.5–35mm² (copper), dual tunnel terminalsA9 more secure, same conductor range
Electrical endurance10,00015,000A9 +50%
Mechanical endurance20,00025,000A9 +25%
Protection degreeIP20IP20 (terminal IP20B)A9 better terminal protection
Accessory compatibilityBasic accessories (aux./shunt)Full Acti9 range (aux., shunt, UVP, remote, и т. д.)A9 more expandable, supports Ti24
StandardsGB16917/IEC60898GB16917/IEC60898/IEC60947‑2A9 covers more standards
Price rangeПриблизительно. ¥150–200Приблизительно. ¥350–500A9 ~2–2.5× EA9 price

2 Detailed Performance Differences

2.1 Разрывная способность: Core Safety Gap

EA9AN4C63: 6тот, suitable for general systems with short‑circuit current ≤6kA.

A9F94463: 15kA high breaking capacity, reliably clears higher short‑circuit currents, reduces arc risk.

Suitable for:

Industrial plants, large commercial buildings

Distribution circuits near transformers

Systems where short‑circuit current may exceed 6kA

2.2 Compact Design: Better Space Utilization

A9F94463 depth only 44.5mm, greatly reduced from EA9AN4C63 78.5mm.

Benefits:

Fits slimmer distribution boards/cabinets

Saves installation space, eases maintenance

Ideal for retrofit projects with limited space

2.3 Endurance & Reliability: Longer‑Term Stability

Electrical endurance from 10k → 15k operations; mechanical 20k → 25k.

A9 series uses higher‑grade materials and precision manufacturing for better long‑term stability.

Better vibration and impact resistance for harsh environments.

2.4 Accessory Expandability: Flexible Function Upgrades

EA9AN: Supports only basic auxiliary contacts and shunt trips.

A9F94463: Supports full Acti9 accessory range:

Multi‑function auxiliary / alarm contacts

Remote‑control shunt trips

Over/undervoltage protection modules

Auto‑reclose accessories

Ti24 interface for PLC/BMS integration

3 Upgrade Decision Guide

Recommended to upgrade to A9F94463 if:

  1. Calculated short‑circuit current >6тот
  2. Critical facilities: industrial, large commercial, hospital, data center
  3. Future expansion needed (remote control, voltage monitoring, и т. д.)
  4. Limited panel space requires compact solution
  5. Higher reliability and longer service life required to reduce maintenance cost

Recommended to keep EA9AN4C63 if:

  1. Standard residential / small shop loads, short‑circuit ≤6kA
  2. Budget‑sensitive, cost priority
  3. Basic protection only, no complex accessories
  4. Already installed EA9 panel with matching system parameters

4 Replacement Notes

  1. Direct interchangeability: Both 4P C63A, DIN‑rail mount – direct replacement.
  2. Wiring check: A9F94463 neutral position matches EA9AN (left) – no need to reorder wiring.
  3. Derating: Both derate at >30°C (–1% per °C).
  4. Accessory compatibility: Existing EA9 accessories must be replaced with Acti9‑specific versions.

Предыдущий:

Оставить ответ