Schneider GV3P50 Motor Circuit Breaker Product Introduction, Этапы установки & Cross-Brand Model Comparison Schneider GV3P50 is a motor circuit breaker belonging to the TeSys GV3 series, mainly used for the protection and control of electric motors. Basic Information Product Type: Thermomagnetic motor circuit breaker Pole Number: 3 poles Control Type: Knob control Rated Operating Voltage: ...

  • Подробная информация о продукте

Schneider GV3P50 Motor Circuit Breaker Product Introduction, Этапы установки & Cross-Brand Model Comparison

Schneider GV3P50 is a motor circuit breaker belonging to the TeSys GV3 series, mainly used for the protection and control of electric motors.

Основная информация

Тип продукта: Thermomagnetic motor circuit breaker

Номер полюса: 3 столбы

Control Type: Knob control

Номинальное рабочее напряжение: 690V AC 50/60Hz

Номинальный ток: 50А

Thermal Protection Adjustment Range: 37-50А

Магнитный ток отключения: 700А

Performance Features

Функции защиты: Equipped with thermomagnetic tripping function, which can effectively protect the motor from overload and short circuit. It also has phase failure protection function, which can act in a timely manner when the motor has a phase failure fault to protect the motor.

Разрывная способность: The ultimate breaking capacity (ICU) is 100kA at 230/240V AC; 50kA at 400/415V AC and 440V AC; 12kA at 500V AC; 6kA at 690V AC.

Durability: Both mechanical and electrical durability reach 50,000 циклы (AC-3 duty at 415V), enabling long-term stable operation in industrial environments.

Способ монтажа: Supports 35mm symmetrical DIN rail mounting and panel mounting with 3 M4 screws for easy installation.

Области применения

Suitable for various motor application scenarios such as workshops, machinery manufacturing, and construction installation, and can reliably protect motors with a power of up to 22kW (at 400V AC).

Installation Steps for Schneider GV3P50 Motor Circuit Breaker

Schneider GV3P50 is a thermomagnetic motor circuit breaker of the TeSys GV3 series, supporting two mainstream mounting methods: 35mm standard DIN rail mounting and panel screw mounting. Installation must comply with industrial electrical construction specifications, focusing on safe power off, mechanical fixation, standard wiring, and post-installation verification. The following is a detailed step-by-step operation (including pre-installation preparation, two fixation methods, wiring, verification and precautions), suitable for the installation scenario of distribution cabinets/control cabinets in industrial sites.

  1. Pre-Installation Preparation

1.1 Safety Prerequisite

All power supplies of the circuit to be installed must be disconnected, and power-off signs must be posted. Operate only after confirming that there is no voltage in the circuit to avoid electric shock.

1.2 Inspection of Product and Accessories

Check that the GV3P50 body has no damage, the wiring terminals have no oxidation, the knob (ON/OFF/reset) operates smoothly, and the tripping mechanism has no jamming;

Verify that the parameters on the product nameplate (rated voltage 690V, rated current 50A, thermal protection 37-50A) match the on-site power supply and motor;

Prepare supporting accessories: 35mm symmetrical DIN rail (for rail mounting), M4 stainless steel screws (for panel mounting, Schneider original torque-adapted accessories), crimp terminals (медный сердечник).

1.3 Tool Preparation

крестовая отвертка (PH2), torque wrench (adapted to 2.5N·m), wire stripper, multimeter, rail cutting/fixing pliers, drilling machine/electric drill (for panel mounting drilling).

1.4 Installation Environment Confirmation

The installation location must meet the protection requirement of IP20 and above (inside distribution cabinet/control cabinet), with an ambient temperature of -25℃~+60℃. Keep away from heat sources, пыль и агрессивные газы, ensure a flat mounting surface, and reserve operation and heat dissipation space (≥5mm on both sides, ≥10mm on the top and bottom).

  1. Method 1: 35mm Standard DIN Rail Mounting (Recommended, Mainstream Method in Distribution Cabinets)

GV3P50 adopts a DIN rail snap-in design, adapted to the industrial universal 35mm symmetrical steel rail, with easy installation and convenient later disassembly and maintenance. The steps are as follows:

  1. Fix the DIN rail: Fix the 35mm standard DIN rail on the mounting plate of the distribution cabinet with screws. The rail must be horizontal, firm and without warpage. The length of a single rail is adjusted according to the number of installed devices. The rail occupation length of the GV3P50 body is about 45mm;
  2. Snap in the circuit breaker: Align the bottom buckle of the GV3P50 body with the upper edge of the DIN rail, press the body down and push it forward slightly until aclicksound is heard to confirm that the bottom buckle is locked to the rail;
  3. Lock the top buckle: Pull the top buckle wrench (small side paddle) of the GV3P50 body to lock the top buckle to the lower edge of the rail to prevent the circuit breaker from loosening in a vibrating environment;
  4. Mechanical fixation verification: Gently shake the circuit breaker left and right, up and down by hand to confirm that there is no relative displacement between the body and the rail, and the knob operates without jamming (after rail mounting, the circuit breaker can slide slightly along the rail; if the position needs to be fixed, rail end caps can be installed at both ends of the rail).
  5. Method 2: Panel Screw Mounting (Suitable for On-Site Independent Control Box/Operation Panel Mounting)

GV3P50 supports panel fixation with 3 M4 screws, adapted to a panel thickness of 1~4mm (2~3mm cold-rolled steel plate/plastic panel is recommended). The steps are as follows:

  1. Mark the mounting hole positions: Attach the GV3P50 body tightly to the mounting panel, and mark the positions of the 3 M4 mounting holes on the body with a marker (distributed in a triangle for precise positioning);
  2. Drill holes on the panel: Drill holes according to the marked positions with a hole diameter of φ4.2mm (slightly larger than M4 screws to avoid thread slipping). Clean the burrs on the panel after drilling to prevent scratching the wires or hands;
  3. Thread the screws for fixation: Pass the M4 screws into the mounting holes from the outside of the panel, align with the threaded holes of the GV3P50 body, initially tighten with a Phillips screwdriver, and then tighten to 2.5N·m with a torque wrench (the torque specified by the original factory to prevent damage to terminals/body due to excessive tightening force);
  4. Firmness check: After tightening, pull the circuit breaker body by hand to confirm no looseness, and the part of the knob exposed on the panel operates smoothly without panel jamming.
  5. Standard Wiring Operation (Core Step to Avoid Poor Contact/Faults)

GV3P50 is a 3-pole circuit breaker, with the upper end as the incoming terminal (Л1/Л2/Л3) and the lower end as the outgoing terminal (Т1/Т2/Т3). Strictly follow the principle ofupper incoming and lower outgoing”, adapted to copper core wires. Direct wiring of aluminum core wires is prohibited (copper-aluminum transition terminals are required). The steps are as follows:

  1. Wire preprocessing: Select the adapted copper core wire according to the on-site current-carrying capacity (recommended wire cross-section for GV3P50: 10~16mm²), strip the wire insulation layer with a wire stripper, and the wire stripping length is 8~10mm (excessively exposed core wire is prone to short circuit, and insufficient length is prone to poor contact);
  2. Crimp the wiring terminals: Crimp the stripped wire core with a cold-pressed copper terminal (tubular/fork type, adapted to 10~16mm² wires) firmly without loose core wires;
  3. Phase-separated wiring: Connect the three-phase power incoming wires to the L1/L2/L3 terminals respectively, and the motor outgoing wires to the T1/T2/T3 terminals respectively with consistent phase sequence correspondence (to prevent motor reverse rotation; if reverse rotation is needed, the phase sequence can be adjusted on the outgoing side);
  4. Torque tightening of terminals: Tighten the wiring terminal screws to 2.5N·m with a torque wrench (unified torque for M4 terminals of the GV3 series). After tightening, pull the wire gently to confirm no looseness and no exposed core wires at the terminals;
  5. Housing grounding: Reliably connect the metal housing grounding terminal of GV3P50 (if equipped, φ4 grounding hole on the side) to the on-site protective ground wire (PE wire). The cross-section of the grounding wire is ≥4mm² copper core to prevent housing electric leakage.
  6. Overall Post-Installation Verification

After the completion of installation and wiring, mechanical and electrical double verification must be carried out, and power can only be supplied after confirming no problems. The steps are as follows:

  1. Mechanical action verification: Manually operate the knob repeatedly from OFF→ON→OFF for 2~3 times to confirm that the closing and opening are in place. The knob points to the red mark in the ON state and the green mark in the OFF state, and the trip reset button does not pop up;
  2. Electrical on-off verification: Measure with the resistance gear of a multimeter. In the ON state of the circuit breaker, the three groups of terminals L1-T1, L2-T2 and L3-T3 are connected respectively (resistance is close to 0); in the OFF state, the three groups of terminals are all disconnected (infinite resistance), with no phase-to-phase short circuit or terminal grounding;
  3. Protection mechanism check: Gently press the trip test button (ТЕСТ) on the body to confirm that the circuit breaker can trip normally and the knob bounces to the OFF position. Then press the reset button to close again, and the trip mechanism acts sensitively.
  4. Key Installation Precautions
  5. Maintain power-off operation throughout the process. Reconfirm that there is no short circuit in the circuit and no reverse wiring before power transmission. It is forbidden to wire/disconnect the wiring when the circuit breaker is in the closed state;
  6. The thermal protection setting value must be adjusted according to the actual rated current of the motor (the adjustment range of GV3P50 is 37~50A). Rotate the thermal protection adjustment knob on the side of the body to align with the corresponding current scale, and do not adjust beyond the range;
  7. Reserve operation space at the installation location. The knob and trip/reset button must be exposed for convenient on-site operation and fault reset, and must not be blocked by other devices in the distribution cabinet;
  8. When multiple GV3 series circuit breakers are installed side by side, the spacing between adjacent devices is ≥5mm to ensure heat dissipation and avoid affecting the protection performance due to excessive temperature rise;
  9. It is forbidden to connect multiple wires to the wiring terminal at the same time. If parallel wiring is needed, use a special parallel terminal to ensure the contact area and prevent heating due to poor contact;
  10. If there is strong vibration on site (such as beside machine tools and pumps), install rail fixing clamps for rail mounting, and select anti-loosening M4 screws (spring washer + flat washer) for panel mounting to prevent the circuit breaker from loosening;
  11. It is forbidden to modify the circuit breaker body without authorization (such as disassembling the tripping mechanism and replacing terminals), otherwise the original Schneider protection performance will be lost and the protection will fail.

Supplementary: Installation Dimension Reference

The installation dimensions of the GV3P50 body (without accessories) are: 45мм (Вт) × 87mm (ЧАС) × 74mm (Д). Installation space must be reserved according to these dimensions for both mounting methods. If auxiliary contacts (such as GVAE11) need to be installed, the width will increase and the space must be reserved synchronously.

Cross-Brand Model Comparison Scheme for Schneider GV3P50 Motor Circuit Breaker

The following are the mainstream brand alternative models of GV3P50 (3 столбы, thermomagnetic type, 37-50А, adapted to 22kW/400V motor), covering the selection of international first-tier and cost-effective domestic brands. Focusing on the four dimensions of function matching, installation compatibility, breaking capacity and cost-effectiveness, it is convenient for procurement replacement and system upgrade decision-making.

  1. Core Benchmark Parameters of GV3P50 (Comparison Basis)
Параметр ЭлементTechnical Specification
Тип продуктаThermomagnetic motor circuit breaker (manual knob control)
Номер полюса3 столбы
Thermal Protection Adjustment Range37-50А
Номинальное рабочее напряжение690V AC 50/60Hz
Разрывная способность (ICU)50kA@400V AC, 100kA@230V AC
Magnetic Trip Multiple14脳In (about 700A)
Adapted Motor Power22кВт (at 400V AC)
Способ монтажа35mm standard DIN rail/panel mounting (45mm width)
Функции защитыTriple protection against overload, short circuit and phase failure
  1. Overall Cross-Brand Alternative Model Comparison Table (Priority Ranking)

The table is grouped by international first-tier brands → cost-effective domestic brands, marking key differences and applicable scenarios:

БрендАльтернативная модельThermal Protection RangeРазрывная способностьInstallation DimensionCore Matching DegreeCost ReferenceApplicable Scenario
Schneider Own SeriesGV3P501 (with EverLink terminals)37-50А50kA@400V45mm width★★★★★ (original factory same specification)100%Original system expansion/spare part replacement
АББMS495-5037-50А50kA@400V45mm width★★★★★95%Industrial automation system, matching with ABB contactors
Сименс3RV5041-4HA1036-50А50kA@400V55mm width (S2 specification)★★★★☆90%Siemens PLC control system, need to reserve an additional 5mm width
3RV6041-4HA10
Eaton MoellerDIL00-5037-50А50kA@400V45mm width★★★★★85%Heavy machinery, adapted to Eaton contactor combinations
DIL0-50
ЧинтNDM2-63M/330037-50А50kA@400V45mm width★★★★☆40%General industrial scenarios, cost performance first
Set to 37-50A
ВкусныйCDM3v-63C/3300237-50А50kA@400V45mm width★★★★☆35%Building electrical/small machinery, first choice for domestic replacement
Set to 37-50A
Changshu SwitchCM3-63M/330037-50А50kA@400V45mm width★★★★☆45%High-end domestic replacement, adapted to harsh working conditions
Set to 37-50A
  1. Detailed Parameter Comparison of Key Models (In-Depth Selection Reference)

3.1 International First-Tier Brands (Complete Function and Performance Matching)

ABB MS495-50

Core Features: Exact same dimension as GV3P50 (45mm width), consistent thermomagnetic tripping curve, supporting dual mounting of rail/panel, and equivalent phase failure protection function;

Terminal Specification: Adapted to 10-16mm² copper wires with a torque of 2.5N·m, compatible with the wiring tools of GV3P50;

Accessory Compatibility: Can be equipped with ABB auxiliary contacts (such as MS132 series), compatible with the accessory mounting position of GV3P50;

Advantage: Excellent synergy with ABB contactors (AX series), suitable for the upgrade and replacement of the original ABB system.

Siemens 3RV5041-4HA10

Core Features: Thermal protection range of 36-50A (covering GV3P50), breaking capacity of 50kA@400V, standard configuration of SIRIUS series;

Differences: 55mm width (10mm wider than GV3P50), need to adjust the installation layout, magnetic trip multiple of 13×In (slightly lower than 14×In of GV3P50);

Advantage: Strong digital communication adaptability with Siemens PLC (S7 series), suitable for production lines with high automation level.

Eaton DIL00-50

Core Features: 45mm standard width, consistent thermomagnetic tripping characteristics with GV3P50, mechanical life of 50,000 раз (same as GV3P50);

Special Advantage: Supports theplug-and-playaccessory system, which can quickly install auxiliary contacts/alarm modules for convenient maintenance;

Adaptation: Perfectly matched with Eaton Icon series contactors, suitable for OEM equipment supporting.

3.2 Cost-Effective Domestic Alternatives (Functional Equivalence, Cost Optimization)

Chint NDM2-63M/3300 (Set to 37-50A)

Core Features: Thermomagnetic tripping, complete triple protection functions, breaking capacity of 50kA@400V, fully meeting the GB14048.4 standard;

Cost Advantage: The price is about 40% of the Schneider original factory, suitable for batch replacement and new economical projects;

Установка: Universal for 35mm DIN rail, the panel mounting hole positions are consistent with GV3P50 without re-drilling.

Delixi CDM3v-63C/33002 (Set to 37-50A)

Core Features: Peak series motor protection circuit breaker with thermal protection accuracy of ±5% (close to the level of international brands);

Added Value: Built-in surge suppression function, suitable for industrial scenarios with large power grid fluctuations;

Совместимость: The wiring terminal specification is the same as GV3P50, which can directly replace the original wiring.

  1. Key Precautions for Replacement and Selection

4.1 Installation Compatibility Check

Prioritize models with 45mm width (such as ABB MS495-50, Eaton DIL00-50) without adjusting the layout of the distribution cabinet;

If the Siemens 3RV5041 series (55mm width) is selected, confirm that the spacing between adjacent devices is ≥10mm to avoid poor heat dissipation.

4.2 Protection Characteristic Matching Principle

The thermal protection range must cover 37-50A, and fixed-value 50A models (such as some domestic simplified versions) are not allowed;

The magnetic trip multiple should be between 12-14×In to ensure the reliability of short circuit protection;

Phase failure protection is a necessary function to avoid motor burnout due to phase loss (this function may be omitted in some economical models).

4.3 Wiring and Accessory Adaptation

The wiring terminals must be adapted to 10-16mm² copper wires with a unified torque of 2.5N·m to prevent heating due to poor contact;

The mounting position of auxiliary contacts (NO/NC) must be compatible with the original system to avoid redesign of the secondary circuit.

4.4 Cost-Effectiveness Balance

Expansion of the original Schneider system: Prioritize GV3P501 (original factory same specification, 100% compatibility);

Cross-brand replacement: International brands (ABB/MS495, Siemens/3RV5041) are suitable for key equipment, and domestic brands (Chint/NDM2, Delixi/CDM3v) are suitable for general loads, with a cost reduction of about 60%.

  1. Recommended Replacement Combination Schemes
Application ScenarioPreferred Recommended ModelReplacement Advantage
Key equipment (such as main motor of production line)ABB MS495-50Consistent performance, strong brand synergy and high reliability
Automation system (equipped with PLC control)Siemens 3RV5041-4HA10Good communication adaptation and complete remote monitoring functions
Batch replacement (such as workshop equipment transformation)Chint NDM2-63M/3300Optimal cost, complete function matching and short delivery cycle
Spare parts for the original Schneider systemGV3P501100% compatibility without any adjustment
МКБ – 1 POLE – 10 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44110
МКБ – 1 POLE – 25 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44125
МКБ – 2 POLE – 6 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44206
МКБ – 2 POLE – 10 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44210
МКБ – 2 POLE – 25 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44225
МКБ – 3 POLE – 6 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44306
МКБ – 3 POLE – 63 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44363
МКБ – 4 POLE – 6 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44406
МКБ – 4 POLE – 20 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44420
МКБ – 4 POLE – 25 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44425
МКБ – 4 POLE – 32 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44432
МКБ – 4 POLE – 40 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44440
МКБ – 4 POLE – 50 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44450
МКБ – 4 POLE – 63 А – 6 KAACTI9IC60NШнайдер ЭлектрикA9F44463
МКБ – 1 POLE – 6 А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24106
МКБ – 1 POLE – 10 А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24110
МКБ – 1 POLE – 16 А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24116
МКБ – 1 POLE – 20А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24120
МКБ – 2 POLE – 10 А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24210
МКБ – 2 POLE – 16 А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24216
МКБ – 2 POLE – 20А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24220
МКБ – 2 POLE – 25А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24225
МКБ – 2 POLE – 32А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24232
МКБ – 2 POLE – 40А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24240
МКБ – 2 POLE – 63А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24263
МКБ – 3 POLE – 32А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24332
МКБ – 3 POLE – 40А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24340
МКБ – 3 POLE – 63А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24363
МКБ – 4 POLE – 32А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24432
МКБ – 4 POLE – 40А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24440
МКБ – 4 POLE – 63А – 6 KAACTI9IK60Шнайдер ЭлектрикA9K24463
МКБ – Acti9 iC40N, 1П+Н, 10 АШнайдер ЭлектрикA9P54610
МКБ – Acti9 iC40N, 1П+Н, 16 АШнайдер ЭлектрикA9P54616
iPRD20 modular surge arrester – 3П + Н – 350ВШнайдер ЭлектрикA9L20600
A9L20200iPRD20 modular surge arrester – 2П – 350ВШнайдер ЭлектрикA9L20200
MOTOR Circuit Breaker THER/MAG 4 – 6.3 A ROCKERШнайдер ЭлектрикGV2ME10
MOTOR Circuit Breaker THER/MAG 6 – 10 A ROCKERШнайдер ЭлектрикGV2ME14
MOTOR Circuit Breaker THER/MAG 9 – 14 A ROCKERШнайдер ЭлектрикGV2ME16
MOTOR Circuit Breaker THER/MAG 17 – 23 A ROCKERШнайдер ЭлектрикGV2ME21
MOTOR Circuit Breaker THER/MAG 24 – 32 A ROCKERШнайдер ЭлектрикGV2ME32
AUX CONTACTШнайдер ЭлектрикGVAE11
CONTACTOR 3P/9 A 4 KW 230V COILШнайдер ЭлектрикLC1D09P7
CONTACTOR 3P/32 A 15 KW 230V COILШнайдер ЭлектрикLC1D32P7
CONTACTOR 3P/40A 18.5 KW 230V COILШнайдер ЭлектрикLC1D40AP7
CONTACTOR 3P/65 A 30 KW 230V COILШнайдер ЭлектрикLC1D65AP7
CONTACTOR 3P/80 A 37 KW 230V COILШнайдер ЭлектрикLC1D80P7
CONTACTOR 3P/95 A 45 KW 230V COILШнайдер ЭлектрикLC1D95P7
AUX CONTACT 1NO1NCШнайдер ЭлектрикLADN11
AUX CONTACT 2NO2NCШнайдер ЭлектрикLADN22
AUX CONTACT 4NOШнайдер ЭлектрикLADN40
iCT 63A 2NO 220…240V 50Hz contactorШнайдер ЭлектрикA9C20862
iCT 40A 4NO 220…240V 50Hz contactorШнайдер ЭлектрикA9C20844
iCT 63A 4NO 220…240V 50Hz contactorШнайдер ЭлектрикA9C20864
CONTACTOR 4P/40 A AC1 230 ВАКШнайдер ЭлектрикLC1DT40P7
CONTACTOR 4P/60 A AC1 230 ВАКШнайдер ЭлектрикLC1DT60AP7
CONTACTOR 4P/80 A AC1 230 ВАКШнайдер ЭлектрикLC1DT80AP7
CONTACTOR 4P/125 A AC1 230 ВАКШнайдер ЭлектрикLC1D80004P7
MECHANICAL INTERLOCK 40AШнайдер ЭлектрикLAD9V2
MECHANICAL INTERLOCK 60-80AШнайдер ЭлектрикLAD4CM
MECHANICAL INTERLOCK 125AШнайдер ЭлектрикLA9D50978
MCCB 4P/32 A NSXШнайдер ЭлектрикC10B6TM032
MCCB 4P/40 A NSXШнайдер ЭлектрикC10B6TM040
MCCB 4P/50 A NSXШнайдер ЭлектрикC10B6TM050
MCCB 4P/63 A NSXШнайдер ЭлектрикC10B6TM063
MCCB 4P/100 A NSXШнайдер ЭлектрикC10B6TM100
MCCB 4P/125 A NSXШнайдер ЭлектрикC16B6TM125
MCCB 4P/160 A NSXШнайдер ЭлектрикC16B6TM160
MCCB 4P/250 A NSXШнайдер ЭлектрикC25B6TM250
MCCB 4P/400 A NSXШнайдер ЭлектрикC40F42D400
MCCB 4P/630 A NSXШнайдер ЭлектрикC63F42D630
MCCB 3P/50 A 25KACVSШнайдер ЭлектрикLV510304
MCCB 3P/63 A 25KACVSШнайдер ЭлектрикLV510305
MCCB 3P/100 A 25KACVSШнайдер ЭлектрикLV510307
MCCB 3P/125 A 25KACVSШнайдер ЭлектрикLV516302
MCCB 3P/160 A 25KACVSШнайдер ЭлектрикLV516303
MCCB 3P/200 A 25KACVSШнайдер ЭлектрикLV525302
MCCB 3P/250 A 25KACVSШнайдер ЭлектрикLV525303
MCCB 3P/320 A 36KACVSШнайдер ЭлектрикLV540305
MCCB 3P/400 A 36KACVSШнайдер ЭлектрикLV540306
MCCB 4P/32 A 25KACVSШнайдер ЭлектрикLV510312
MCCB 4P/50 A 25KACVSШнайдер ЭлектрикLV510314
MCCB 4P/63 A 25KACVSШнайдер ЭлектрикLV510315
MCCB 4P/80 A 25KACVSШнайдер ЭлектрикLV510316
MCCB 4P/100 A 25KACVSШнайдер ЭлектрикLV510317
MCCB 4P/125 A 25KACVSШнайдер ЭлектрикLV516312
MCCB 4P/160 A 25KACVSШнайдер ЭлектрикLV516313
MCCB 4P/200 A 25KACVSШнайдер ЭлектрикLV525312
MCCB 4P/250 A 25KACVSШнайдер ЭлектрикLV525313
MCCB 4P/320 A 36KACVSШнайдер ЭлектрикLV540308
MCCB 4P/400 A 36KACVSШнайдер ЭлектрикLV540309
MCCB 4P/630 A 36KACVSШнайдер ЭлектрикLV563309