Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

 Schneider MT08N1 3P 800A - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

Schneider MT08N1 3P 800A

Schneider MT08N1 3P 800A is a fixed 3-pole intelligent air circuit breaker (ACB) belonging to the Masterpact MT series. It has a frame current and rated current of 800A, with an N1-class breaking capacity (50kA@400V). Suitable for incoming line/bus tie protection and power distribution in power distribution systems, it is commonly used in primary/secondary power ...

  • Подробная информация о продукте

Schneider MT08N1 3P 800A is a fixed 3-pole intelligent воздушный выключатель (ACB) belonging to the Masterpact MT series. It has a frame current and rated current of 800A, with an N1-class breaking capacity (50kA@400V). Suitable for incoming line/bus tie protection and power distribution in power distribution systems, it is commonly used in primary/secondary power distribution of industrial plants, large buildings and data centers. Below are the complete specifications and core details:

Основные технические параметры

ЭлементParameterRemarks
ModelMT08N1 3P 800A (Order Code: MT08N1)MT series; 08=800A frame; N1=50kA breaking capacity
SeriesMasterpact MT (Air Circuit Breaker)Intelligent type, zero arcing, compatible with Micrologic control units
Номер полюсаThree-phase power distribution, no neutral protection (4P optional)
Номинальный ток (In)800А (at 40℃)Long-term continuous current-carrying capacity
Frame Current (Iu)800АMaximum current adaptable to the breaker body
Rated Operational Voltage (Ue)690V AC 50/60HzInsulation Voltage (Ui) = 1000V
Short-circuit Breaking Capacity (Ику)50тот (400V AC)N1 class, соответствует МЭК 60947-2
Short-time Withstand Current (Icw)42kA/1s (400В)Ability to withstand short-circuit impact
Making Capacity (Icm)105тот (440V AC)Ability to close short-circuit current
Impulse Withstand Voltage (Uimp)12kVStrong surge resistance
Control UnitCompatible with Micrologic 2.0/5.0/6.0, и т. д..Long-time delay/short-time delay/instantaneous/earth fault protection
Mounting MethodFixed (F) / Drawout (Д)Standard dimensions for fixed 3P model: 301×276×196mm
Способ подключенияFront/back panel screw clamping terminalsSuitable for top/bottom cable entry
Operation MethodЭлектрический + manual (for maintenance)Equipped with closing/opening buttons and status indicators
Mechanical/Electrical Service Life10,000 mechanical operations; 2,000 electrical operations (АС-3)High durability
CertificationsCCC, МЭК, UL, CSA, EACGreen Premium compliant

Основные функции & Protection Features

  1. Full Intelligent Protection: Realizes long-time delay (overload), short-time delay (short circuit), instantaneous (heavy short circuit) and earth fault protection via the Micrologic control unit. Parameters can be precisely set to adapt to cascade coordination in multi-level power distribution systems.
  2. Measurement & Monitoring: Displays real-time electrical parameters such as current, voltage and power, with fault memory and alarm output functions. Supports Modbus and other communication protocols, and can be integrated into SCADA systems.
  3. Zero Arcing Design: Optimized arc extinguishing chamber with zero arcing distance, improving cabinet safety and space utilization.
  4. Функция изоляции: Compliant with IEC 60947-2, can be used as an isolating switch (without controller).

Application Scenarios & Selection Key Points

Typical Scenarios: Primary/secondary power distribution links such as incoming line cabinets of industrial plants, power distribution of large buildings, UPS output of data centers, photovoltaic/energy storage combiner boxes, и т. д.. It is used for power distribution and short-circuit, overload, earth fault protection of lines/equipment.

Key Selection Tips:

Control Unit: 2.0 for basic protection; 5.0/6.0 with added measurement and communication functions, select according to requirements.

Mounting Type: Fixed type is cost-effective; drawout type facilitates maintenance and allows breaker replacement without power outage.

– Разрывная способность: N1 (50тот) meets general power distribution needs; upgrade to N2/H1/H2 class if short-circuit current is high.

Procurement & Replacement Recommendations

  1. Complete Order Specification: Must specify MT08N1 + control unit model + mounting method + pole number, например, MT08N1 F MIC 2.0 3П.
  2. Replacement Compatibility: Can directly replace MT08N2/H1 and other models with the same frame size. Dimensions differ from the NW series; verify cabinet installation space before replacement.
  3. Price Reference (December 2025): Domestic fixed type with MIC 2.0 control unit is approximately RMB 14,500-16,000 per unit; drawout type is priced higher.

Breaking Capacity Comparison Table of Schneider Masterpact MT08 Series (800А)

ЭлементMT08N1 3P 800AMT08N2 3P 800AMT08H1 3P 800AMT08H2 3P 800ARemarks
Breaking Capacity ClassN1N2H1H2N=Standard type; H=High breaking type
Rated Ultimate Short-circuit Breaking Capacity (Ику) @400V AC50тот70тот100тот150тотCompliant with IEC 60947-2
Rated Service Short-circuit Breaking Capacity (Ics) @400V AC50тот (100% Ику)70тот (100% Ику)100тот (100% Ику)150тот (100% Ику)Can carry rated current continuously after breaking
Short-time Withstand Current (Icw) @400V AC/1s42тот50тот85тот120тотAbility to withstand short-circuit impact
Making Capacity (Icm) @440V AC105тот147тот210тот315тотAbility to close short-circuit current
Rated Operational Voltage (Ue)690V AC690V AC690V AC690V ACInsulation Voltage (Ui) = 1000V
Номинальный ток (In)800А (at 40℃)800А (at 40℃)800А (at 40℃)800А (at 40℃)Frame Current (Iu) = 800A
Optional Pole Number3P/4P3P/4P3P/4P3P/4P4P with neutral protection
Mounting MethodFixed/DrawoutFixed/DrawoutFixed/DrawoutFixed/DrawoutDrawout type requires additional chassis
Compatible Control UnitsMicrologic 2.0/5.0/6.0/7.0Micrologic 2.0/5.0/6.0/7.0Micrologic 2.0/5.0/6.0/7.0Micrologic 2.0/5.0/6.0/7.07.0 is a high-end measurement and control unit, supporting power quality analysis
Dimensions (Fixed 3P, W×H×D)301×276×196mm301×276×196mm301×276×210mm301×276×225mmHigh breaking types have slightly increased depth due to optimized arc extinguishing chambers
Mechanical Service Life10,000 операции10,000 операции10,000 операции10,000 операцииElectrical service life: 2,000 операции (АС-3)
Price Reference (December 2025, Fixed Type + Micrologic 2.0)RMB 14,500-16,000/unitRMB 17,000-19,000/unitRMB 22,000-25,000/unitRMB 28,000-32,000/unitDrawout type: 30%-40% price increase; imported model: about 50% price increase
Типичные сценарии примененияGeneral industrial plants, incoming line/bus tie of building power distributionMedium-voltage distribution outgoing terminals, industrial scenarios with high short-circuit currentHeavy industrial plants, data centers, photovoltaic/energy storage combiner systemsPower grids with high short-circuit current, supporting large generator setsSelect according to grid short-circuit current level

Complete Order Code Examples & Stocking Recommendations

  1. Complete Order Code Specification (4 Core Elements Required)

Ordering Schneider MT series requires specifying frame size + breaking capacity class + mounting method + control unit + pole number. Examples are as follows:

MT08N1 F MIC 2.0 3П: 800A N1 class, fixed type, Micrologic 2.0 control unit, 3-pole

MT08H1 D MIC 5.0 4П: 800A H1 class, drawout type, Micrologic 5.0 control unit, 4-pole

  1. Stocking & Рекомендации по выбору
  2. Select by Short-circuit Current

First calculate the expected short-circuit current at the distribution point: choose N1 class (highest cost-performance) if ≤50kA; N2 class if 50-70kA; H1/H2 class if >70тот.

For industrial plants close to substations with high short-circuit current, prioritize H1 class.

  1. Select by Operation & Maintenance Requirements

Choose fixed type for general power distribution scenarios, featuring low cost and small space occupation;

Choose drawout type for scenarios where power outage for maintenance is not allowed (например, data centers, hospitals), enabling live replacement of the breaker body.

  1. Select by Functional Requirements
Control Unit ModelОсновные функцииApplicable Scenarios
Micrologic 2.0Basic protection (long-time delay/short-time delay/instantaneous)General power distribution without measurement and control requirements
Micrologic 5.0Protection + electrical parameter measurement (current/voltage/power)Buildings and factories requiring energy consumption monitoring
Micrologic 6.0Protection + measurement + communication (Modbus/Profibus)Intelligent power distribution systems requiring SCADA integration
Micrologic 7.0Full functions + power quality analysis (harmonics/unbalance)Data centers, precision manufacturing workshops
  1. Stocking Recommendations

For regular trade stocking, prioritize MT08N1 F MIC 2.0 3П, which adapts to 80% of general power distribution scenarios and ensures fast inventory turnover;

For heavy industry customers, stock a small quantity of MT08H1 F MIC 5.0 3P to meet high short-circuit current requirements;

Customize drawout models on demand; large-scale stocking is not recommended (high capital occupation and strong model specificity).

Core Parameter Comparison Table: Schneider MT08 Series vs. Chint NA8G-800 Series

(Both are 800A frame, 3-pole, fixed type, basic protection type, suitable for general power distribution scenarios)

Comparison ItemSchneider MT08N1 3P 800A (Micrologic 2.0)Chint NA8G-800-3P-800A (Basic Trip Unit)Core Difference Summary
Product Series PositioningMasterpact MT series intelligent air circuit breakerNA8G series air circuit breakerSchneider focuses on intelligent measurement & control + high reliability; Chint focuses on high cost-performance + localized adaptation
Rated Ultimate Short-circuit Breaking Capacity (Ику) @400V50тот40тотSchneider’s breaking capacity is 25% выше, suitable for scenarios with high short-circuit current
Rated Service Short-circuit Breaking Capacity (Ics) @400V50тот (100% Ику)40тот (100% Ику)Both support continuous operation after breaking; Schneider has higher redundancy
Short-time Withstand Current (Icw) @400V/1s42тот31.5тотSchneider has stronger short-circuit impact resistance, suitable for heavy-duty industrial scenarios
Функции защитыLong-time delay/short-time delay/instantaneous three-stage protection; expandable earth fault protectionLong-time delay/short-time delay/instantaneous three-stage protection; earth fault protection requires customizationBasic protection is consistent; Schneider offers more flexible expansion functions
Measurement & Control CapabilitySupports electrical parameter display (current/voltage); can be equipped with communication modules for SCADA integrationBasic protection only, no measurement and control functions; measurement supported only by upgraded models (NA8G-800M)Schneider has higher intelligence level, suitable for intelligent power distribution needs
Mounting MethodFixed/drawout optional; drawout type with standard mechanical interlockFixed/drawout optional; drawout interlock is optionalSimilar structural design; Schneider’s standard interlock offers higher safety
Dimensions (Fixed 3P, W脳H脳D)301脳276脳196mm320脳285脳210mmSchneider is more compact, saving cabinet space
Mechanical/Electrical Service Life10,000 mechanical operations; 2,000 electrical operations (АС-3)8,000 mechanical operations; 1,500 electrical operations (АС-3)Schneider has better durability, suitable for high-frequency operation scenarios
Certification StandardsCCC, МЭК, UL, CSA, EACCCC, МЭКSchneider has broader certification coverage, suitable for export projects
Price Reference (December 2025, Fixed Type)RMB 14,500-16,000/unitRMB 6,500-7,500/unitChint’s price is about 45%-50% of Schneider’s, with outstanding cost-performance
Типичные сценарии примененияIndustrial plant incoming lines, data centers, high-end buildings, export projectsCivil building power distribution, small and medium-sized factories, localized power distribution renovation projectsSelect according to project budget and reliability requirements
After-sales ServiceNationwide warranty, extensive overseas network; spare parts supply cycle: about 7 дниNationwide warranty, fast localized service response; spare parts supply cycle: about 3 дниChint’s after-sales service is more suitable for domestic small and medium-sized customers

Selection Decision Recommendations

  1. Scenarios for Prioritizing Schneider MT08 Series

Export projects (например, overseas markets such as Algeria), power distribution projects requiring international certifications;

Scenarios with high requirements for short-circuit breaking capacity and reliability, such as data centers and heavy industrial plants;

Intelligent power distribution systems requiring energy consumption monitoring and remote control.

  1. Scenarios for Prioritizing Chint NA8G-800 Series

Domestic civil buildings, small and medium-sized factories and other general power distribution scenarios with limited budgets;

Localized renovation projects requiring fast delivery and after-sales response;

Power distribution circuits with only basic short-circuit and overload protection needs, no intelligence requirements.

  1. Replacement Compatibility Notes

The two series have slightly different mounting dimensions; verify cabinet installation space before replacement;

Chint NA8G series can upgrade measurement and control functions by installing intelligent trip units (например, NA8G-M), with the cost still lower than that of similarly configured Schneider models.