МодельFunctional DifferencesПрименимые сценарии
RE22R2AMRTime delay on power-on, single functionBasic sequence control
RE22R2KMRTime delay on power-off, dual outputDelayed shutdown after equipment stops
RE22R2QTMRDedicated for star-delta starting, supporting multi-mode switchingMotor step-down starting

  • Подробная информация о продукте

The following is a detailed analysis of the Schneider RE22R2QEMR реле времени. Combining the latest search resources and technical documents, we provide you with comprehensive technical parameters, operation guides, and application suggestions:

Core Parameters and Functional Features

  1. Основные параметры

Voltage Range: 24-240V AC/DC (wide voltage compatibility, supporting mainstream global industrial power supplies)

– Конфигурация контактов: Double Pole Double Throw (2CO), with a maximum load current of 8A (резистивная нагрузка)

Time Range: 0.3 seconds to 30 секунды (adjustable in ranges, supporting three ranges of 0.3-3s, 1-10с, and 3-30s)

– Точность: ±10% (full scale, in compliance with IEC 61812-1 стандартный)

– Рабочая температура: -20°C to +60°C (adapting to harsh industrial environments)

– Способ установки: 35mm DIN rail or panel installation, with a depth of 79.5mm and a width of 90mm

Certifications: International certifications such as UL, CSA, CCC, and RoHS.

  1. Functional Highlights

Dual Knob Adjustment: The top knob selects the time range (например, the 10-second range), and the bottom knob sets the percentage (например, 70% corresponds to 7 секунды), with intuitive operation.

Diagnosis and Status Indication:

– Желтый “Rindicator light: Lights up when the output is activated.

Test button: Supports manual triggering of the time delay function for quick verification of the circuit.

Safety Protection

Front panel with IP50 protection, resistant to dust and small water droplets.

Housing with IP40 protection, adapting to industrial environment vibrations (20m/s²) and impacts (15g).

  1. Application Scenarios and Typical Cases
  2. Промышленная автоматизация

– Управление двигателем: Star-delta starting sequence control (например, RE22R2QEMR supports the star-delta mode).

Production Line Synchronization: Delayed start and stop of conveyor belts to avoid idling of equipment.

Equipment Preheating: Delayed start of the cooling fan after the heating element is powered on.

  1. Системы отопления, вентиляции и кондиционирования

Fan Control: In air conditioning systems, the fan is turned off with a delay after the compressor stops to prevent condensate water from flowing back.

Water Pump Protection: Avoid current surges caused by the simultaneous start of multiple water pumps.

  1. Building and Energy

Lighting Control: Delayed light-off function in parking lots or warehouses.

Fire Protection Systems: Delayed start of the smoke exhaust fan after a fire alarm.

III. Operation and Maintenance Guide

  1. Time Setting Steps
  2. Select the time range: Switch the range through the top knob (например, the 10-second range).
  3. Fine-tune the percentage: Adjust the specific time with the bottom knob (например, 70% corresponds to 7 секунды).
  4. Verify the setting: Press the test button and observe the yellow indicator light and the action of the contacts.

Примечание: There may be an error of ±10% in the actual time delay, and a margin should be reserved according to the requirements of the scenario.

  1. Пример подключения

Power Connection: Connect A1 (+) and A2 (-) to the 24-240V AC/DC power supply.

Load Connection:

Normally open contacts (15-18, 25-28): Close with a delay.

Normally closed contacts (15-16, 25-26): Open with a delay.

Control Signal: Trigger the action of the relay through an external signal (например, PLC output).

Tip: The circuit diagram is printed on the side of the relay, and the wiring method can be quickly confirmed.

  1. Поиск неисправностей

Indicator light not on: Check whether the power voltage and fuse are normal.

Contacts not operating: Clean the oxide layer on the contacts and check whether the load is overloaded.

Inaccurate time delay: Confirm whether the knob setting is correct, or replace the relay.

  1. Alternative Models and Purchase Suggestions
  2. Альтернативные модели
МодельFunctional DifferencesПрименимые сценарии
RE22R2AMRTime delay on power-on, single functionBasic sequence control
RE22R2KMRTime delay on power-off, dual outputDelayed shutdown after equipment stops
RE22R2QTMRDedicated for star-delta starting, supporting multi-mode switchingMotor step-down starting
  1. Каналы покупки

Authorized Dealers: Use theDistributor Searchfunction on the Schneider official website and enter the region to filter certified suppliers.

Price Reference: The average market price of RE22R2QEMR is approximately WA: 0086-13811255435 yuan. For bulk purchases, you can contact the dealer to negotiate the price.

  1. Precautions and Compliance Requirements
  2. Model Confirmation: Avoid confusing similar models (например, RE22R2QGMR is a multi-functional version). It is recommended to use the Schneider product selection tool.
  3. Safety Specifications:

Ensure that the power is disconnected during installation to avoid electric shock.

The contact load shall not exceed 8A; в противном случае, an intermediate relay needs to be equipped.

  1. Document Acquisition:

Official Manual: Visit the Schneider Support Center and search forRE22R2QEMRto download the PDF manual.

Detailed Technical Parameters of Schneider RE22R2QEMR Time Relay

The following is an analysis of the detailed technical parameters of the Schneider RE22R2QEMR time relay. Combining the latest technical documents and industrial application scenarios, we provide you with comprehensive performance indicators and design references:

  1. Основные электрические параметры
Parameter NameTechnical IndexApplication Value
Номинальное напряжение24-240V AC/DC (Wide voltage compatibility, 50/60Гц)Supports mainstream global industrial power supplies, reducing adaptation costs
Power Consumption переменного тока: 3VA (at 240V)Low-power design, suitable for long-term operation
округ Колумбия: 1.5Вт (at 240V)
Contact TypeDouble Pole Double Throw (2CO), Cadmium-free Silver Alloy ContactsEnvironmentally friendly and with strong arc resistance, suitable for high-reliability scenarios
Контактная емкостьResistive Load: 8A/250V ACCovers various load types such as motors, heaters, and solenoid valves
Inductive Load: 3A/250V AC (Power Factor 0.4)
Capacitive Load: 1A/250V AC
Электрическая жизньResistive Load: 100,000 операцииStrongly related to the load type, and the maintenance cycle needs to be evaluated according to the actual application
Inductive Load: 10,000 операции
Capacitive Load: 5,000 операции
Механическая жизнь3.2 миллион операций (B10d standard, МЭК 61812-1)Long-life design, suitable for scenarios with high-frequency actions
  1. Time Control Parameters
Parameter NameTechnical IndexTechnical Details
Time Range0.3 seconds to 30 секунды (Adjustable in three ranges)Knob adjustment, supporting fine adjustment at the 0.1-second level (например, the 10-second range can be accurate to 0.1 второй)
– 0.3-3 секунды
– 1-10 секунды
– 3-30 секунды
Точность±10% (Full scale, at 25°C)Industrial-grade accuracy, meeting most timing control requirements
Repeat Accuracy±0.5% (Full scale)High stability, suitable for scenarios with repeated actions (such as production line cycle control)
Response Time≤100ms (Typical value 50ms)Fast triggering, suitable for devices with high real-time requirements
Reset Time≤120ms (After power-off)Ensures quick restoration to the initial state and avoids misoperation

III. Mechanical and Environmental Parameters

Parameter NamTechnical IndexDesign Advantages
Размеры22.5мм (Width) × 79.5mm (Depth) × 90mm (Height)Compact design, saving control cabinet space
Weight90gLightweight, facilitating installation and maintenance
Способ установки35mm DIN Rail (EN 50022) or Panel InstallationSupports multiple fixing methods, adapting to different cabinet structures
Уровень защитыHousing: IP40Dust-proof and splash-proof, adapting to harsh industrial environments
Front Panel: IP50
– Терминалы: IP20
Рабочая температура20°C to +60°C (No condensation)Wide temperature range operation, suitable for extreme climatic conditions
Storage Temperature-40°C to +70°CStrong long-term storage stability
Vibration/ShockVibration: 20m/s² (10-150Гц)Resistant to mechanical stress, suitable for vibrating environments (such as mobile devices)
Shock: 15g (11РС)
  1. Safety and Certifications
Parameter NameTechnical IndexCompliance
Insulation Resistance≥100MΩ (500V DC)High insulation performance, ensuring electrical safety
Dielectric Strength2.5kV AC (1 minute, between input and output)Соответствует МЭК 61812-1 стандартный
EMC CompatibilitySurge Resistance: 2kV (Common Mode)Industrial-grade anti-interference ability, suitable for complex electromagnetic environments
Radio Frequency Interference Resistance: 10V/m (80MHz-1GHz)
Certifications МЭК 61812-1 (Time Relay Standard)Global market access, reducing certification costs
C257UL 508 (Industrial Control Equipment)
CE,CSA, CCC, RoHS -ECCSACCC
  1. Functional Features and Design Highlights
  2. Dual Knob Adjustment

Top Knob: Select the time range (например, the 10-second range).

Bottom Knob: Fine-tune the percentage (например, 70% corresponds to 7 секунды).

Sealed Cover Design: Prevents accidental touching of the adjustment knobs and ensures parameter stability.

  1. Diagnosis and Testing

LED Indicator Light: The yellowRlight indicates the output status.

Test Button: Manually triggers the time delay function to quickly verify the circuit logic.

  1. Environmental Friendliness and Reliability

Cadmium-free Contacts: Complies with the RoHS directive, reducing environmental pollution.

High MTTFd: Mean Time To Failure on Demand is 353.8 годы (МЭК 61709 стандартный), suitable for critical mission scenarios.

  1. Parameter Adaptation for Typical Application Scenarios
Application FieldLoad TypeTime Setting ExampleContact Configuration Suggestions
Пуск двигателя звезда-треугольник7.5kW Three-phase MotorStar Operation for 10 seconds → Delta OperationNormally closed contacts control the star contactor
HVAC Fan Control220V AC FanTurn off with a 30-second delay after shutdownNormally open contacts control the power-off delay
Lighting System100W LED LampTurn off with a 30-second delay after personnel leaveNormally closed contacts are connected in series in the lighting circuit
Fire Smoke Exhaust24V DC Solenoid ValveStart immediately after the alarm and last for 10 минутыNormally open contacts directly drive the solenoid valve

VII. Selection and Maintenance Suggestions

  1. Comparison of Alternative Models
МодельDifferencesПрименимые сценарии
RE22R2AMRSingle output, time delay on power-onBasic timing control
RE22R2KMRDual output, time delay on power-offDelayed shutdown after equipment stops
RE22R2QTMRDedicated for star-delta, supports multi-mode switchingMotor step-down starting
  1. Maintenance Cycle

Contact Inspection: Clean the oxide layer on the contacts every 6 months to ensure that the contact resistance ≤ 50mΩ.

Parameter Calibration: Verify the time delay accuracy using an oscilloscope every year. Replace it when the error exceeds ±15%.

  1. Поиск неисправностей

Abnormal Indicator Light: Check the power supply voltage (allowable fluctuation ±15%).

Contact Sticking: Measure the load current and avoid exceeding the 8A peak value.

Time Delay Drift: When the ambient temperature exceeds +50°C, it needs to be derated (for every 10°C increase, the service life is halved).

VIII. Official Resources and Purchase Information

Technical Documents: The Schneider official website provides the RE22R2QEMR Data Sheet (Document Number: SDOC-RE22R2QEMR-01), which contains detailed circuit diagrams and wiring guidelines.

– Каналы покупки:

For further verification of parameters or obtaining customized solutions, it is recommended to provide specific application scenarios (such as load type, ambient temperature, installation method, etc.) to facilitate the recommendation of the optimal configuration.

Предыдущий: