Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Siemens 3VT8-63H102 Molded Case Circuit Breaker (MCCB) - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

автоматический выключатель/

Siemens 3VT8-63H102 Molded Case Circuit Breaker (MCCB)

Модельный сегментSpeculative MeaningDescription
3VT8Siemens SENTRON 3VT8 Series Molded Case Circuit BreakerDiscontinued, replaced by 3VA/3VM/3VC series
63Номинальный ток (In): 63АMaximum current for long-term operation at 40掳C ambient temperature
ЧАСBreaking Capacity Class: Class H (50тот)Breaking capacity classes of 3VT8 series: Class N (25тот), Class H (50тот), Class L (65тот)
102Speculated as a combination of frame current + pole number/trip unit type100A frame (VT100), 2-pole configuration, Thermal-Magnetic Trip unit (TMF)

  • Подробная информация о продукте

Model Designation Interpretation (Speculative, Based on 3VT8 Series Naming Rules)

The model “3VT8-63H102provided by the user is a simplified version; the complete model usually contains more detailed information. The speculative meaning of each part is as follows:

Модельный сегментSpeculative MeaningDescription
3VT8Siemens SENTRON 3VT8 Series Molded Case Circuit BreakerDiscontinued, replaced by 3VA/3VM/3VC series
63Номинальный ток (In): 63АMaximum current for long-term operation at 40掳C ambient temperature
ЧАСBreaking Capacity Class: Class H (50тот)Breaking capacity classes of 3VT8 series: Class N (25тот), Class H (50тот), Class L (65тот)
102Speculated as a combination of frame current + pole number/trip unit type100A frame (VT100), 2-pole configuration, Thermal-Magnetic Trip unit (TMF)

Most Probable Corresponding Complete Models: 3VT8106-1AA03-0AA0 (3-столб, 63А, Class H breaking capacity, TMF trip unit) or 3VT8106-1AA04-0AA0 (4-столб)

  1. Core Specification Parameters (Based on 3VT8 100H 63A TMF)
Параметр ЭлементСпецификация ЗначениеDescription
Тип продуктаMolded Case Circuit Breaker (MCCB)Used for overload and short-circuit protection in power distribution systems
Ток кадра (Iu)100АVT100 frame, compatible with a maximum rated current trip unit of 63A
Номинальный ток (In)63АRated operating current at 40掳C ambient temperature
Максимальная отключающая способность (Ику)50тот (415/440В и)Class H breaking capacity, meeting the requirements of industrial power distribution systems
Trip Unit TypeThermal-Magnetic Trip unit (TMF)Защита от перегрузки (thermal element): inverse time characteristic; Защита от короткого замыкания (magnetic element): instantaneous tripping
Номер полюса3-pole or 4-pole3-pole is commonly used in power distribution systems; 4-pole is adopted when neutral wire protection is required
Rated Operational Voltage (Ue)400/415В иSuitable for three-phase industrial power distribution systems
Номинальное напряжение изоляции (Ui)690В иCompliant with IEC 60947-2 стандартный
Рабочая температура-25C ~ +70CDerating is required when the temperature exceeds 40C
Способ подключенияFront Panel WiringRear panel wiring or plug-in connection is optional
Метод работыПоворотная ручкаElectric operating mechanism is optional for remote control

III. Product Features and Advantages

  1. Высокая надежность: A member of Siemens SENTRON series, compliant with the international IEC 60947-2 стандартный.
  2. Высокая отключающая способность: Class H 50kA breaking capacity, effectively interrupting short-circuit faults and protecting equipment safety.
  3. Flexible Configuration: Compatible with a variety of accessories (вспомогательные контакты, alarm contacts, shunt release, undervoltage release, и т. д.).
  4. Safety Design: Lockable rotary operating mechanism to prevent misoperation; Terminal cover protection for enhanced safety.
  5. Compact Size: Saving switchgear space, facilitating installation and maintenance.
  6. Типичные сценарии применения
  7. Industrial Power Distribution Systems: Used as incoming/outgoing circuit breakers in distribution boxes to protect cables and lines.
  8. Motor Protection: Serves as protection equipment for direct starting of three-phase squirrel-cage motors, providing overload and short-circuit protection.
  9. Transformer/Capacitor Protection: Protecting distribution transformers and compensation capacitors to prevent fault expansion.
  10. Main Switch/Emergency Stop Switch: Combined with a lockable operating mechanism, used as the main switch and emergency stop control for equipment or systems.
  11. Building Automation: Applied in power distribution protection for lighting, air conditioning and other systems in commercial buildings and industrial plants.
  12. Important Notes and Alternative Solutions
  13. Product Status

The 3VT8 series was officially discontinued in January 2024 and fully replaced by Siemensnew-generation 3VA/3VM/3VC series molded case circuit breakers. The 3VT8 series is no longer in production, with only limited spare parts support available.

  1. Recommended Alternative Models (Based on 63A, Class H Breaking Capacity, 3-столб, TMF Trip Unit)
Alternative SeriesRecommended ModelAdvantages
3VA1 Series3VA1063-3ED36-0AA0Higher breaking capacity (25kA→36kA), more advanced tripping technology, richer accessory options
3VM Series3VM1063-1EA00-0AA0Cost-effective, suitable for basic power distribution applications, easy to install
3VC Series3VC1063-1AA00-0AA0Thermal-magnetic and electronic trip units optional, high intelligence level, supporting communication functions
  1. Precautions for Use
  2. Derating Operation: When the ambient temperature exceeds 40°C, the rated current must be derated according to the temperature coefficient.
  3. Accessory Matching: Pay attention to matching the accessory with the circuit breaker model and pole number when selection, such as the voltage level of the shunt release.
  4. Installation Specifications: Ensure installation in a switchgear that meets requirements, with proper ventilation and heat dissipation maintained.
  5. Регулярное техническое обслуживание: Periodically inspect the circuit breaker appearance, operating mechanism and trip unit performance to ensure reliable operation.
  6. Replacement Suggestion: For new projects, it is recommended to directly select 3VA/3VM/3VC series alternative products to achieve better performance and a longer service life.

Предыдущий:

Оставить ответ

Оставить сообщение