Yaskawa Inverter CIMR-HB4A0009FBC (Marked as 15kW)
Yaskawa inverter model CIMR-HB4A0009FBC is actually a 2.2kW unit of the H1000 series for 3-phase 400V supply, not a 15kW model. The corresponding 15kW models are CIMR-HB4A0039FBC (heavy duty) and CIMR-HB4A0031FBC (standard duty). Below are the core parameters, functional features and key selection points of the CIMR-HB4A0009FBC model:
Основные технические параметры
| Параметр | Ценить |
| Модель | CIMR-HB4A0009FBC |
| Ряд | H1000 (Heavy Duty Special) |
| Rated Power | 2.2кВт (heavy duty) / 3.7кВт (standard duty) |
| Input Power | 3-phase 380-480V AC, 50/60Гц |
| Rated Output Current | 10.4А (heavy duty) / 8.9А (standard duty) |
| Control Method | High-performance vector control (for induction/synchronous motors) |
| Перегрузочная способность | 150% rated current for 60s (heavy duty) |
| Коммуникационный интерфейс | RS-485 as standard, Modbus RTU supported |
| Класс защиты | NEMA Type 1 (IP20) |
| Cooling Method | Forced air cooling |
Функциональные особенности
- Heavy Duty Adaptation: Specifically designed for heavy-duty working conditions such as cranes, crushers and belt conveyors, with high overload and impact resistance.
- Precise Control: Supports sensorless vector control, featuring stable high torque output at low speed, fast torque response and vibration/over-shoot suppression.
- Safe and Reliable: Equipped with comprehensive protection functions including overcurrent, перенапряжение, пониженное напряжение, overheating and ground fault protection, suitable for harsh industrial environments.
- Flexible Expansion: Supports optional accessories such as PG cards and I/O expansion cards, and is compatible with a variety of fieldbuses to meet complex control requirements.
Corresponding 15kW Models & Selection Tips
15kW Heavy Duty: CIMR-HB4A0039FBC (suitable for continuous high-load scenarios)
15kW Standard Duty: CIMR-HB4A0031FBC (suitable for normal working conditions)
При выборе модели, verify the load type, номинальный ток, power supply specifications and communication/expansion requirements to avoid mismatch between power and working conditions.
Common Application Scenarios
Applicable to heavy machinery in mining, metallurgy, building materials and other industries, such as hoists, mixers and calenders that require high torque output and frequent start-stop operations.
The following is a complete parameter comparison between Yaskawa CIMR-HB4A0009FBC and its corresponding 15kW models, as well as recommended direct replacement models of the same power from ABB, Siemens and Schneider.
- Таблица сравнения основных параметров (Yaskawa H1000 Series)
| Параметр | CIMR-HB4A0009FBC (Original Inquired Model) | CIMR-HB4A0031FBC (15kW Standard Duty) | CIMR-HB4A0039FBC (15kW Heavy Duty) |
| Ряд | H1000 (Heavy Duty Special) | H1000 | H1000 |
| Rated Power | 2.2кВт (HD) / 3.7кВт (SD) | 15кВт (SD) | 15кВт (HD) |
| Input Power | 3-phase 380-480V AC, 50/60Гц | 3-phase 380-480V AC, 50/60Гц | 3-phase 380-480V AC, 50/60Гц |
| Rated Output Current | 10.4А (HD) / 8.9А (SD) | 27А (SD) | 34А (HD) |
| Перегрузочная способность | 150% rated current for 60s (HD) | 120% rated current for 60s (SD) | 150% rated current for 60s (HD) |
| Control Method | High-performance vector control (Ind/Syn motors) | High-performance vector control (Ind/Syn motors) | High-performance vector control (Ind/Syn motors) |
| Коммуникационный интерфейс | RS-485 as standard, Modbus RTU supported | RS-485 as standard, Modbus RTU supported | RS-485 as standard, Modbus RTU supported |
| Класс защиты | NEMA Type 1 (IP20) | NEMA Type 1 (IP20) | NEMA Type 1 (IP20) |
| Cooling Method | Forced air cooling | Forced air cooling | Forced air cooling |
| Adapted Load | Light to medium heavy load (например. small conveyors, mixers) | Normal working conditions (например. фанаты, водяные насосы) | Heavy load (например. cranes, дробилки, hoists) |
| Rated Torque | 7.16N路m (HD) / 12.0N路m (SD) | 47.7Nm | 47.7Nm |
| Max Output Frequency | 400Гц | 400Гц | 400Гц |
| Braking Unit | Необязательный | Необязательный | Необязательный |
- Cross-brand Direct Replacement Models for 15kW Heavy Duty Inverters
All the following models are adapted to 3-phase 380-480V power supply, 15kW heavy duty working conditions (150% overload for 60s), and support vector control and mainstream communication protocols:
| Бренд | Ряд | Модель | Core Features | Adapted Scenarios |
| АББ | ACS880 (All-compatible Drive) | ACS880-01-038A-3 | Direct Torque Control (DTC), built-in STO safety function, suitable for cranes/hoists | Heavy machinery in mining, metallurgy, building materials industries |
| Сименс | SINAMICS G120 | 6SL3210-1PE31-5UL0 (PM250 Power Module) + CU250S-2 (Control Unit) | Модульная конструкция, PROFIBUS/PROFINET supported, high-precision vector control | Industrial automation production lines, heavy-duty conveyors |
| Шнайдер | ATV930 (Altivar Process) | ATV930D15N4 | Integrated braking unit, Modbus/TCP supported, built-in multiple process macros | Chemical industry, water treatment, heavy-duty mixers |
III. Key Tips for Model Selection & Замена
- Load Matching as Priority
Confirm the load type (constant torque/variable torque), overload requirement (120%/150%) and duty type (S1/S3), and prioritize models rated for the corresponding type.
For heavy-duty scenarios (например. cranes, дробилки), CIMR-HB4A0039FBC or equivalent heavy-duty models from other brands must be selected to avoid damage caused by long-term overload.
- Key Parameter Verification
Номинальный ток: ≥34A required for 15kW heavy duty, ≥27A for standard duty.
Control functions: Vector control, PG feedback (encoder interface) and communication protocols (Modbus/Profinet, и т. д.) must be compatible with the original system.
Safety functions: СТО (Safe Torque Off), EDM (External Device Monitoring) and other functions must match the safety grade requirements of the equipment.
- Установка & Expansion
Installation dimensions: The 15kW model of Yaskawa H1000 series is about 260×550×190mm; verify the cabinet space before replacement.
Accessory compatibility: PG cards, I/O expansion cards, braking resistors and other accessories must be compatible with the new model to avoid function loss.
- Replacement Implementation Suggestions
- Record the parameters of the original inverter (motor nameplate, V/f curve, acceleration/deceleration time, protection thresholds, и т. д.) before replacement for quick commissioning of the new model.
- Perform motor auto-tuning (static/dynamic) on the new model to ensure the accuracy of vector control and stability of torque output.
- Verify the pin definitions for communication and I/O wiring to avoid equipment abnormalities caused by signal errors.
- Monitor key indicators such as current, voltage and temperature during the test phase to verify the replacement effect and adjust parameters accordingly.