This document provides model correspondence, power coverage, core parameters, application scenarios and replacement recommendations for frequency converters of 12 mainstream global brands, facilitating rapid cross-brand selection and replacement. It covers four application categories: general-purpose, fan & pump-specific, heavy-duty industrial, and economical.
- General-Purpose Frequency Converter Comparison (0.37kW~75kW)
| Brand | Series | Power Range | Control Method | Core Features | Typical Model | Replacement Reference |
| เอบีบี | ACS580 | 0.37kW~250kW | Vector Control/Sensorless Vector | Rugged and durable, IP55 protection optional, built-in EMC | ACS580-01-04A5-4 (2.2กิโลวัตต์) | Siemens G120, Schneider ATV340 |
| ซีเมนส์ | SINAMICS V20 | 0.12kW~30kW | V/f Control/Vector Control | Easy operation, integrated filter, suitable for OEM | 6SL3210-5BE17-5UV0 (7.5กิโลวัตต์) | ABB ACS150, Delta VFD-E |
| ซีเมนส์ | SINAMICS G120 | 0.37kW~250kW | Vector Control/Servo Control | การออกแบบโมดูลาร์, PROFINET integration | 6SL3224-0BE27-5UA0 (30กิโลวัตต์) | ABB ACS580, Schneider ATV340 |
| ชไนเดอร์ | Altivar 320 | 0.37kW~75kW | Vector Control/Torque Control | Compact size, built-in PLC function | ATV320U07M2C (0.75kW single-phase) | Mitsubishi FR-D740, Fuji FRENIC-Mini2 |
| ชไนเดอร์ | Altivar 340 | 0.37kW~250kW | Advanced Vector Control | Adaptive control, multi-pump linkage | ATV340D15N4 (15กิโลวัตต์) | ABB ACS580, Siemens G120 |
| Mitsubishi | FR-A800 | 0.4kW~500kW | Vector Control/Torque Control | 200% torque output at 0.5Hz, suitable for heavy loads | FR-A840-00720-2-60 (30กิโลวัตต์) | Yaskawa A1000, Danfoss FC302 |
| Mitsubishi | FR-D740 | 0.4kW~75kW | V/f Control/Basic Vector | Economical, compact size | FR-D740-015SC-EC (7.5กิโลวัตต์) | Chint NVF2, Delixi CDI9100 |
| Yaskawa | A1000 | 0.4kW~500kW | Vector Control/Position Control | Fast response speed, high torque precision | CIMR-AB4A0018FBA (7.5กิโลวัตต์) | Mitsubishi FR-A800, Siemens G120 |
| Fuji | FRENIC-MEGA | 0.75kW~630kW | Vector Control/Direct Torque | Triple overload protection, suitable for shock loads | FRN0015E2S-4C (7.5กิโลวัตต์) | Yaskawa A1000, ABB ACS580 |
| Delta | VFD-E | 0.4kW~75kW | Vector Control/Torque Control | Built-in EMI filter, RS485 communication | VFD037E43A (3.7กิโลวัตต์) | Schneider ATV320, Mitsubishi FR-D740 |
| Inovance | MD280 | 0.4kW~75kW | Vector Control/Sensorless Vector | High-quality domestic product, cost-effective, strong adaptability | MD280T3.7GB (3.7กิโลวัตต์) | Delta VFD-E, Chint NVF2 |
| ชินท์ | NVF2 | 0.75kW~90kW | V/f Control/Vector Control | Mainstream domestic brand, 3C certified, suitable for civil engineering | NVF2-11/TS4 (11กิโลวัตต์) | Delixi CDI9100, Delta VFD-E |
- Fan & Pump-Specific Frequency Converter Comparison
| Brand | Series | Power Range | Special Functions | Energy Efficiency Class | Typical Model | Replacement Recommendation |
| เอบีบี | ACS380 | 0.37kW~160kW | Multi-pump control, sleep/wake-up function | IE2+ | ACS380-040S-03A3-4 (1.5กิโลวัตต์) | Schneider ATV630, Danfoss FC111 |
| เอบีบี | ACH550 | 0.75kW~500kW | HVAC-specific, enthalpy control | IE2+ | ACH550-UH-03A3-4 (1.5กิโลวัตต์) | Schneider ATV630, Johnson Controls Frequency Converter |
| ชไนเดอร์ | Altivar 630 | 0.75kW~630kW | Fan surge suppression, pump dry-run protection | IE3 | ATV630U15N4 (15กิโลวัตต์) | ABB ACS380, Danfoss FC111 |
| Danfoss | FC111 | 0.37kW~160kW | Automatic energy optimization, sleep mode | IE3 | 131B0100 (4กิโลวัตต์) | ABB ACS380, Schneider ATV630 |
| Mitsubishi | FR-F740 | 0.75kW~450kW | Fan/pump-specific algorithm, energy-saving mode | IE2 | FR-F740-030SC-EC (15กิโลวัตต์) | Fuji FRENIC-NewVP, Yaskawa H1000 |
| Fuji | FRENIC-NewVP | 0.75kW~630kW | Multi-pump cycle control, stable pipe network pressure | IE3 | FRN0030E2S-4C (15กิโลวัตต์) | Mitsubishi FR-F740, Schneider ATV630 |
III. Heavy-Duty Industrial Frequency Converter Comparison (75kW~500kW)
| Brand | Series | Power Range | Overload Capacity | สถานการณ์การใช้งาน | Typical Model | Technical Highlights |
| เอบีบี | ACS880 | 0.75kW~5.6MW | 180%/60ส | Heavy industry, multi-machine parallel operation, energy feedback | ACS880-01-09A5-3 (4กิโลวัตต์) | Torque response < 5ms, supports synchronous motor control |
| ซีเมนส์ | SINAMICS S120 | 0.5kW~4.5MW | 200%/3ส | High-precision servo, complex motion control | 6SL3120-1TE28-5AA3 (45กิโลวัตต์) | Vector control accuracy 0.01%, digital twin integration |
| Yaskawa | H1000 | 1.5kW~630kW | 180%/60ส | Hoisting/lifting, คอมเพรสเซอร์, large fans | CIMR-HB4A0090FBC (37กิโลวัตต์) | Built-in braking unit, suitable for potential energy loads |
| Danfoss | FC302 | 0.75kW~250kW | 170%/60ส | Textile machinery, extruders, heavy-duty pumps | 132F0040 (15กิโลวัตต์) | Adaptive motor model, low harmonic output |
| Inovance | MD880 | 11kW~500kW | 180%/60ส | High-quality domestic heavy-duty product, suitable for metallurgy/mining | MD880T45G (45กิโลวัตต์) | 30% cost reduction compared with imported brands, close performance |
- Economical Frequency Converter Comparison (0.12kW~15kW)
| Brand | Series | Power Range | Price Range | สถานการณ์การใช้งาน | Typical Model | Replacement Advantages |
| เอบีบี | ACS150 | 0.37kW~15kW | Medium-Low | Small pumps/fans, simple machinery | ACS150-03E-01A2-4 (0.75กิโลวัตต์) | Compact size, easy installation, IP20 protection |
| Delta | VFD-M | 0.4kW~15kW | Medium-Low | Small automation equipment, OEM supporting | VFD007M43B (0.75กิโลวัตต์) | Cost-effective, simple operation, strong adaptability |
| ชินท์ | NVF1 | 0.75kW~15kW | ต่ำ | Civil construction, small machinery, cost priority | NVF1-015/TS4 (15กิโลวัตต์) | Entry-level domestic brand, 3C certified, convenient after-sales service |
| Delixi | CDI9100 | 0.75kW~15kW | ต่ำ | Replacement for Chint NVF1, slightly better performance | CDI9100-0R75G/1R5P (0.75กิโลวัตต์) | Lower price, suitable for domestic power grid fluctuations |
- Core Principles and Precautions for Cross-Brand Replacement
- Three Essential Factors for Replacement Selection (Must Match)
| Factor | Matching Standard | Risk of Mismatch |
| Power Rating | Rated current ≥ original model, power deviation ≤ ±5% | Overload protection failure, module burnout |
| Control Method | At least equivalent to the original model (Vector→Vector, V/f→V/f) | Performance degradation, insufficient control precision |
| Voltage Rating | Input/output voltage completely consistent (380V/400V/690V) | Insulation breakdown, equipment damage |
- Key Parameter Checklist
- Overload Capacity: Must be ≥150%/60s for heavy-duty applications, ≥120%/60s for general loads
- ระดับการป้องกัน: Select IP20 (indoor cabinet)/IP54 (outdoor)/IP66 (underwater) as required
- Communication Protocol: Modbus/Profibus/Profinet/EtherNet/IP must be compatible with the system
- ขนาดการติดตั้ง: Ensure consistent rail/panel mounting holes during replacement to avoid re-drilling
- Accessory Compatibility: Braking units, filters, and reactors must match the parameters of the new frequency converter
- Recommended Common Replacement Combinations
| Original Brand Series | Recommended Replacement Brand Series | Replacement Advantages |
| Siemens V20 | ABB ACS150/Schneider ATV320 | Lower price, equivalent functions |
| ABB ACS550 | Siemens G120/Schneider ATV340 | Updated technology, lower maintenance cost |
| Mitsubishi FR-D740 | Delta VFD-E/Inovance MD280 | Domestic replacement, cost-effective |
| Schneider ATV312 | Chint NVF2/Delixi CDI9100 | 40% cost reduction, meets basic requirements |
- Quick Selection Decision Table
| Application Scenario | Preferred Brand Series | Power Range | Control Method | Essential Functions |
| Small Fans/Pumps | ABB ACS150, Siemens V20 | 0.37kW~7.5kW | V/f Control | Sleep function, overload protection |
| Medium-Sized Industrial Machinery | ABB ACS580, Siemens G120 | 11kW~75kW | Vector Control | Built-in EMC, communication interface |
| Large Fans/Pumps | ABB ACS380, Schneider ATV630 | 30kW~250kW | Special Algorithm | Multi-pump control, anti-surge |
| Heavy-Duty Equipment/Hoisting | ABB ACS880, Yaskawa H1000 | 45kW~500kW | Vector Control + Braking | 180% โอเวอร์โหลด, energy feedback |
| Cost-Priority Projects | Delta VFD-E, Inovance MD280 | 0.75kW~37kW | Vector Control | Basic functions, 3C certification |
- Model Naming Rules: There are significant differences in model coding among various brands. Focus on three core parts: power code, voltage rating, and control method
- Latest Replacement Information:
ABB ACS550 has been upgraded to ACS580 (fully compatible with installation dimensions)
Siemens MM4 series has been replaced by SINAMICS V20/G120
Schneider ATV312 has been upgraded to ATV320 (enhanced functions, smaller size)
- Domestic Replacement Trend: Domestic brands such as Inovance, Delta and Chint have approached the performance of imported brands in the 0.75kW~37kW power range, with a price advantage of 30%~50%
คอนแทคเตอร์,เบรกเกอร์,อินเวอร์เตอร์พลังงานแสงอาทิตย์,มิเตอร์ไฟฟ้า,แบตเตอรี่พลังงานแสงอาทิตย์