SIEMENS MPCB 3RV1374-7GN10

3RV1374-7GN10|SIEMENS SIRIUS High‑Performance Motor Protection Circuit‑Breaker (MPCB)

Full Model: 3RV1374-7GN10 (Siemens SIRIUS 3RV1 series, moulded case circuit‑breaker with enhanced breaking capacity for starter combinations)

ยี่ห้อ: Siemens SIRIUS Industrial Control Series

  1. Detailed Model Breakdown
Model PartความหมายKey Description
3RV1SeriesSIRIUS 3RV1 series, moulded case motor protection circuit‑breaker, designed with enhanced breaking capacity for starter combinations
374SizeLarge size, rated current 400A, suitable for 200kW three‑phase motors at 400V
7Breaking Capacity ClassEnhanced breaking capacity, up to 200kA@400V
Trip TypeElectronic trip unit, short‑circuit protection adjustable from 1–10 × In
เอ็นConnectionขั้วต่อสกรู, with phase barriers for safe and reliable connection
10จำนวนเสา3 เสา (3P3d), for three‑phase motor protection circuits
  1. Core Technical Data
Itemข้อมูลจำเพาะหมายเหตุ
Rated Operational Current (In)400ก (ที่ตายตัว)For 200kW three‑phase induction motors at 400V
แรงดันไฟฟ้าที่ได้รับการจัดอันดับ (อือ)690วีและFor medium‑high voltage industrial motor control systems
จัดอันดับแรงดันไฟฟ้าของฉนวน (อุ้ย)1000วีและHigher than operating voltage, large safety margin
Ultimate Breaking Capacity (ห้องไอซียู)200kA@400VEnhanced breaking capacity for heavy short‑circuit faults
Poles3 เสา (3P3d)Standard three‑phase motor protection
Trip CharacteristicMagnetic only (short‑circuit protection only)Electronic trip, short‑circuit adjustable 1–10×In; must be used with overload relay
OperationRotary ON/OFF actuatorManual control, simple and clear
MountingPanel mountingSuitable for control cabinet integration
Degree of ProtectionIP30Standard for switchgear installation
Applicable StandardIEC 60947‑4‑1International standard for motor protection devices
  1. Key Features & Applications

Main Advantages

  1. Ultra‑high breaking capacity: 200kA@400V, withstands heavy short‑circuit faults in industrial networks
  2. Precise protection: Electronic trip with adjustable short‑circuit protection for various motor starting characteristics
  3. Reliable connection: Screw terminals with phase barriers to prevent phase‑to‑phase short circuits
  4. System integration: Designed for starter combinations, works perfectly with contactors and overload relays
  5. Durable design: Industrial‑grade quality, suitable for harsh environments and long mechanical life

การใช้งานทั่วไป

Large industrial motor control centers (MCC), 400V/690V systems

Short‑circuit protection for three‑phase induction motors up to 200kW at 400V (must be used with overload relay)

High‑power motor protection in metallurgy, mining, paper and other heavy industries

Large continuous‑duty equipment: คอมเพรสเซอร์, แฟน ๆ, ปั๊ม

Main drive motors in production lines with frequent starting and fluctuating loads

  1. Replacement Models

Upgrades / Replacements (Same Brand)

แบบอย่างKey DataคุณสมบัติApplication
3VA2240‑0MS32‑0AA0400ก, 200kA@400V, 3ป, การเดินทางทางอิเล็กทรอนิกส์Upgrade replacement for 3RV1, new 3VA2 series MCCBNew projects requiring higher performance and communication
3RV1374‑7KN10400ก, 200kA@400V, 3ป, การเดินทางทางอิเล็กทรอนิกส์Different terminal configurationSame rating, different connection requirements
3RV1374‑7GN20400ก, 200kA@400V, 4ป, การเดินทางทางอิเล็กทรอนิกส์4‑pole version with neutral protectionThree‑phase four‑wire systems needing neutral protection

Cross‑Brand Alternatives

ยี่ห้อแบบอย่างMatching Specifications
เอบีบีTmax T4H 400 PR221DS400ก, 100kA breaking, การเดินทางทางอิเล็กทรอนิกส์, 3ป
ชไนเดอร์TeSys GV4‑ME400400ก, 100kA breaking, thermal‑magnetic trip, 3ป
MitsubishiNF400‑SEW400ก, 100kA breaking, การเดินทางทางอิเล็กทรอนิกส์, 3ป
  1. Protection coordination: This unit provides magnetic only (short‑circuit) protection and must be used with an overload relay (e.g. 3RU series) for complete motor protection.
  2. Breaking capacity matching: Selected based on system short‑circuit calculation; 200kA suits most industrial grids.
  3. Wiring: Screw terminals for copper/aluminum cables; observe cross‑section and torque specifications.
  4. Mounting space: Large frame size requires sufficient cabinet space.
  5. Upgrade recommendation: Some 3RV1 models are discontinued; 3VA2 series is recommended for new projects for advanced protection and communication.
  6. Accessories: Auxiliary contacts, alarm contacts available for motor status monitoring and control.