Grundfos DDE 6-10 B-PP/E/C-X-31I001FG Diaphragm Dosing Pump
رقم المادة: 97720906|Grundfos SMART Digital DDE Economy Digital Diaphragm Dosing مضخة (Stepper Motor Driven)
انهيار رمز النموذج
DDE 6-10 B-PP/E/C-X-31I001FG
- DDE: مسلسل, economy digital dosing pump (النموذج الأساسي, differs from premium DDA/DDC)
- 6: Max flow rate 6 L/h
- 10: Max working pressure 10 حاجِز
- ب: Control version = Basic, manual adjustment + pulse signal input control
- ص: Pump head material = Polypropylene
- ه: Seal material = EPDM (ethylene propylene diene monomer, resistant to water, weak acids & weak alkalis)
- ج: Ball material = Ceramic
- X: Valve type = Standard double ball valve (non-spring-loaded)
- 31I001: الجهد االكهربى / region / connection code: 230الخامس 50 هرتز, I = Australia & New Zealand specification, 4/6mm hose connection
- FG: Cable and certification configuration code
Core Technical Data
Max flow: 6 L/h; Min flow: 6 mL/h
Turn-down ratio: 1:1000, logarithmic adjustment knob 0.1~100% continuous regulation
يقود: Stepper motor, full-stroke operation, stable dosing even with aerated media
غشاء: Solid PTFE diaphragm
كرر الدقة: ≤5%
فئة الحماية: IP65 / نيما 4X
Max medium viscosity: 50 mPa·s
Built-in air vent valve for easy priming
Control modes: Local manual, external pulse input (dividable)
الشهادات: م, CSA-US, NSF61, مجموعة شرق أفريقيا, آلية التنسيق الإقليمية
التطبيقات النموذجية
معالجة المياه (raw water, مياه الصرف الصحي, ماء الغلاية, تعميم مياه التبريد), ريال عماني & ultrafiltration, swimming pools, light chemical dosing, sodium hypochlorite, حامض & alkali dosing (subject to EPDM chemical compatibility)
ملحوظة: EPDM is not suitable for strong oxidants, concentrated chlorine or aromatic solvents. For high-chlorine applications, select V (FKM) إصدار.
Equivalent Series Reference (for selection & استبدال)
DDE 6-10 B-PP/V/C-X-31I001FG: PP pump head + FKM seals (sodium hypochlorite resistant)
DDE 6-10 B-PVC/E/C-X-31I001FG: PVC pump head + الأختام EPDM
DDE 6-10 B-PV/T/C-X-31I001FG: PVDF pump head + PTFE seals (heavy corrosion)
الملحقات الاختيارية (طقم التثبيت)
Foot valve, injection valve, PE discharge tubing, PVC suction tubing, vent tubing, compression fittings (4/6mm hose)
Spare Parts List for DDE 6-10 B-PP/E/C-X-31I001FG (97720906)
Pump configuration: PP pump head + الأختام EPDM + ceramic ball valves (SD-S-1-PP/E/C-2, S-series for 6~9L/h flow range)
Complete Repair Kit (الأكثر شعبية, Full Set)
97751105|Pump Head Repair Kit SD-S-1-PP/E/C-2
Contains:
- PTFE composite main diaphragm
- Suction valve assembly (ceramic ball + EPDM seat seal)
- Discharge valve assembly (ceramic ball + EPDM seat seal)
- Pump head O-rings and small sealing gaskets
- Fixing screws, shims and air vent components
Compatible with DDE 6-10 and equivalently configured DDA 6–9L/h, PP/E/C combination
تذكيرات: Grundfos S-series (≤15L/h) does not supply loose individual balls or diaphragms as standalone OEM part numbers. Factory supply prioritizes complete valve kits or diaphragm+valve kits; loose single parts on the market are mostly aftermarket.
Split Kits (Separate Procurement If Required)
- Valve Kit (suction + discharge valves only, no diaphragm)
شفرة: SD-S-PP/E/C-2 valve assembly (8-digit material number to be retrieved via Grundfos channel using pump PN 97720906)
Contents: 2 sets of valve assemblies (Al₂O₃ ceramic ball + EPDM valve seals)
- Diaphragm Only Kit (PTFE diaphragm only, no valves)
شفرة: SD-S-1-PP diaphragm kit, also retrieved by pump serial/material number
Material Breakdown (Cross-check for replacements)
غشاء: PTFE faced diaphragm with support flange
Valve ball: Al₂O₃ alumina ceramic ball
Valve seat O-ring / main pump head O-ring: إبدم (E code)
Pump head body: Polypropylene (ص)
If upgraded to sodium hypochlorite resistant version (V=FKM), repair kit PN will change and cannot be interchanged.
Cross-reference for different material sets (stocking reference)
PP/V/C (FKM seal for chlorine): Different repair kit PN from 97751105
PVDF/T/C (PTFE seal for heavy corrosion): Separate SD-S-PVDF/T/C-2 valve kit
PVC/E/C: Dedicated repair kit PN for PVC pump head variant
Grundfos DDE 6-10 B-PP/E/C-X-31I001FG Troubleshooting Guide
Applicable to DDE economy digital diaphragm dosing pump, PP pump head + EPDM seal + ceramic ball valve configuration
Precaution: Isolate power before service. Wear protection for corrosive chemicals; ensure ventilation for hypochlorite, acid and alkali media.
- عيب: Pump runs, no suction / no chemical output
| أعراض | السبب المحتمل | يفحص & علاج |
| Stepper motor runs normally, stroke action visible, no discharge | Air trapped inside pump head, insufficient priming | 1. Open manual air vent valve on pump head;2. Keep suction hose fully submerged to drain air from piping;3. Cycle pump at low flow to purge bubbles; close vent after air removed |
| Air leakage on suction side (الأكثر شيوعا) | Inspect foot valve, hose ferrules, cracked tubing;شيخوخة / kinked PE tubing or loose fittings leak air;Submerge foot valve ≥10cm below liquid level; avoid suction pipe above tank liquid level | |
| Suction/discharge valve stuck, ball stuck or fouled | Dismantle valve assemblies, clean ceramic balls and EPDM seats;Dirt, scale or crystals prevent tight sealing;Inspect balls for chipping or cracking | |
| Foot valve clogged / foot valve check valve failed | Remove and clean foot valve strainer; replace foot valve if worn or jammed | |
| Diaphragm ruptured | Check vent port and pump housing for chemical leakage;Medium entering drive chamber means diaphragm failure; shut down and replace repair kit | |
| رفع الشفط المفرط | DDE has limited self-priming capability; flood suction side preferred (tank above pump); vertical suction lift ≤2m | |
| Medium viscosity out of range | Viscosity >50 mPa·s exceeds pump specification, poor priming |
- عيب: Inaccurate flow, low/high actual output, flow drift
| أعراض | السبب المحتمل | يفحص & علاج |
| Metered flow deviates from setpoint, persistently low flow | Air ingress or poor valve sealing (same as above leakage issues) | Perform air purge and suction side leak test first; this is the #1 cause of flow inaccuracy |
| Valve ball / seat wear, crystal buildup, poor sealing | Dismantle and clean valve assemblies; EPDM ages and swells under continuous high chlorine exposure – replace repair kit | |
| Diaphragm fatigue, reduced swept volume | Diaphragm creep after long runtime; replace full repair kit | |
| Unstable outlet backpressure, backpressure too low | Install backpressure valve on dosing pump outlet; free flow siphoning occurs without backpressure valve, causing uncontrolled flow;This pump rated 10 حاجِز; continuous low-pressure siphoning leads to over-dosing | |
| Pulse control mode: wrong pulse scaling or faulty signal source | Verify pulse ratio and scaling parameters for external pulse control;Switch to local manual mode to isolate pump fault vs controller signal fault | |
| Changing chemical temperature or crystallisation | Temperature changes alter density; crystals accelerate valve wear and gradual flow decay | |
| Calibration lost | Re-calibrate by timed volumetric collection and re-set calibration on pump panel |
- عيب: ضجيج غير طبيعي, اهتزاز
| أعراض | السبب المحتمل | يفحص & علاج | |
| Regular tapping / clicking sound with unstable discharge | Ball hammering seat (typical air-bound noise) | Purge air first; cavitation causes dry ball impact noise | |
| متصدع / chipped ceramic ball | Disassemble valve set; replace valve kit if ceramic ball damaged | ||
| Hum from motor, اهتزاز شديد, intermittent output | Piping resonance, loose hose supports | Add pipe clamps; avoid rigid hard pipe tension pulling pump inlet/outlet | |
| Pump installed off-level, pump head under stress | Mount pump horizontally; prevent hose tension pulling pump head | ||
| Stepper motor overload, diaphragm jammed | DDE has no manual crank; energise and observe stroke movement;Jammed crystals or debris on diaphragm increase load | ||
| Intermittent high-pitched whistling | Over-restriction / dead-head pressure or cavitation | Check for blocked outlet piping or clogged injection valve; clean injection check valve |
- Other Common Faults
- عرض عادي, no pumping action at all
Power supply fault / انخفاض الجهد; check 230V supply and loose terminals
Keypad lock active; unlock panel
- Leakage at pump head
Aged pump head O-rings, uneven bolt torque; tighten pump head bolts diagonally and evenly
Ruptured diaphragm with chemical leaking into drive side → stop immediately, replace repair kit
- Continuous dripping from air vent
Worn vent valve seal; replace vent valve component or full repair kit
Recommended Diagnostic Sequence
- Confirm power supply and control mode (local / نبض)
- Vent air → inspect suction side for air leaks
- Volumetric flow test to confirm true pump fault or signal issue
- Dismantle and inspect valve assemblies, ceramic balls and EPDM seals
- Inspect diaphragm for rupture and leakage
- Check outlet backpressure valve and injection valve for blockage or failure
- Final action: replace complete pump head repair kit (97751105)
أمان & ملاحظات الصيانة
For crystallising media (باك, phosphate, high brine), flush pump head and valves with clean water after shutdown to prevent seizure
EPDM seals are not suitable for long-term high-concentration sodium hypochlorite service; use V variant (FKM) for chlorine dosing
Tighten pump head bolts diagonally and evenly; uneven torque can crack PP pump head
Grundfos SMART Digital DDE Series List (S-series ≤15L/h Economy Range)
Important separation: S-series small flow DDE (6-10 /15-4) (the model above); separate XL large flow DDE (60/120/200 L/h). Spare parts are NOT interchangeable.
Control variants exclusive to DDE: ب / ص / PR
ب: Basic|manual adjustment + pulse input (your unit: DDE 6-10 ب)
ص: ب + external start/stop + low-level input
PR: ص + تتابع إخراج التنبيه (stroke signal, تتابع الخطأ)
- S-series DDE (low flow 0–15 L/h, تستخدم على نطاق واسع) النماذج الأساسية
| النموذج الأساسي | Max Flow | Max Pressure | Turn-down Ratio | Min Flow |
| DDE 6-10 | 6 L/h | 10 حاجِز | 1000:01:00 | 0.006 L/h (6 mL/h) |
| DDE 15-4 | 15 L/h | 4 حاجِز | 1000:01:00 | 0.015 L/h (15 mL/h) |
تنسيق النموذج الكامل:
DDE Flow-Pressure Control Code-Pumphead/Seal/Ball-Valve Type-Voltage Region Code FG
مثال: `DDE 6-10 B-PP/E/C-X-31I001FG`
Material Combinations (Pumphead / ختم / Ball)
PP/E/C: PP pump head + EPDM seal + ceramic ball (your configuration, fresh water, weak acid/alkali)
PP/V/C: PP pump head + ختم FKM + ceramic ball (sodium hypochlorite, chlorine media)
PVC/E/C: PVC pump head + EPDM seal + ceramic ball
PVC/V/C: PVC pump head + ختم FKM + ceramic ball
PVDF/T/C: PVDF pump head + PTFE seal + ceramic ball (strong acid / heavy corrosion)
PP/E/SS: ص + إبدم + stainless steel ball (special abrasion service)
Valve Type Codes
X: Standard double ball valve (non-spring-loaded, الغرض العام)
ح: Spring-loaded valve (unstable backpressure, high viscosity media)
الجهد االكهربى / Region Codes (شائع)
31I001: 230الخامس 50 هرتز, RCM AU/NZ, 4/6mm hose compression (your unit)
31U2U2: 100–240V universal voltage, م, EU specification
31V: 110V North America version
S-series Finished Model Examples (Direct for PO)
- DDE 6-10 B-PP/E/C-X-31I001FG (PN 97720906|your pump)
- DDE 6-10 B-PP/V/C-X-31I001FG (chlorine resistant same rating)
- DDE 6-10 PR-PP/V/C-X-31U2U2FG|alarm relay, الجهد العالمي
- DDE 15-4 B-PP/E/C-X-31I001FG|15L/h 4bar, إبدم
- DDE 15-4 P-PVDF/T/C-X-31U2U2FG|PVDF heavy corrosion, التحكم في النبض
- SMART Digital XL DDE (Large Flow 60~200 L/h, نطاق مستقل)
XL pump head structure and repair kits are incompatible with S-series 6-10 /15-4
| DDE 60-10 | 60 L/h | 10 حاجِز |
| DDE 120-7 | 120 L/h | 7 حاجِز |
| DDE 200-4 | 200 L/h | 4 حاجِز |
XL example:
DDE 60-10 B-PP/V/C-F-31U3U3FG
- DDE Control Variant Function Table
| Control Code | Manual Adjustment | Pulse Input | External Stop / مستوى منخفض | Relay Alarm Output |
| ب | ✅ | ✅ | ❌ | ❌ |
| ص | ✅ | ✅ | ✅ | ❌ |
| PR | ✅ | ✅ | ✅ | ✅ (2 المرحلات) |
- تمايز السلسلة (Avoid mixing with DDC / DDA)
DDE: اقتصاد, basic function, no 4-20mA analog input, فعالة من حيث التكلفة (OEM water treatment standard)
DDC: Standard grade, 4-20أماه التناظرية, extended menu, additional alarms
DDA: Premium grade, built-in FCM flow monitoring, دقة عالية, batch dosing, complex interlock
- Spare Part Cross-reference Summary
S-series (6-10 /15-4): Repair kit family SD-S-1-xxx, ب.ن 97751105 for PP/E/C
XL series (60/120/200): Dedicated XL repair kits, not interchangeable
- إرشادات الاختيار السريع
- Sodium hypochlorite / chlorine dioxide dosing: prefer `/V/` (FKM), avoid EPDM `/E/`
- Concentrated acid / heavy corrosion: PVDF `/T/`
- Unstable backpressure or siphon risk: select H spring-loaded valve instead of X standard valve
- Standard domestic global supply: prefer 31U2U2 universal voltage; AU/NZ export use 31I001
المقاولين,قاطع الدائرة,الاستشعار,التشفير,بلك,محول