ABB 2TLA020070R1700 Programmable Safety Controller

ماركة: ABB-Jokab Safety;منتج: Programmable Safety Controller (سلامة PLC) Model Definition 2TLA020070: Base part number for Pluto-series safety controllers R1700: Order suffix for hardware revision B46 v2 Full designation: Pluto B46 v2 I-O Configuration (المجموع 46 Points) 24 fail-safe inputs (safety inputs) 16 configurable channels: non-safe output / مدخلات السلامة 4 independent safety relay outputs 2 ...

  • تفاصيل المنتج

ماركة: ايه بي بي-Jokab Safety;منتج: Programmable Safety Controller (أمان بلك)

تعريف النموذج

2TLA020070: Base part number for Pluto-series safety controllers

R1700: Order suffix for hardware revision B46 v2

Full designation: Pluto B46 v2

I-O Configuration (المجموع 46 Points)

  1. 24 fail-safe inputs (safety inputs)
  2. 16 configurable channels: non-safe output / مدخلات السلامة
  3. 4 independent safety relay outputs
  4. 2 independent safety transistor outputs

Equipped with Pluto Safety-Bus safety fieldbus for networking expansion

Key Safety & المواصفات الكهربائية

غرضالمعلمة
مزود الطاقة24 VDC
مستوى السلامةSIL3 / PLe (EN ISO 13849‑1)
فئة الحمايةIP20 (DIN‑rail cabinet mounting)
المحطاتScrew‑type terminals
Relay Contacts2 أ, AC250V / DC50V
درجة حرارة التشغيل‑10 ℃ ~ +55 ℃
رطوبة5‑95 %, غير التكثيف
برامج البرمجةPluto Manager
تواصلModbus‑TCP native; expandable via gateways for Profibus/EtherNet‑IP, إلخ.

التطبيقات النموذجية

Machine safety control: أوقف, safety gates, safety light curtains, التحكم باليدين, safe speed monitoring; multi-controller safety networking, standalone high-I/O safety projects.

Series Comparison Reference

Pluto B20 v2: 20 نقاط الإدخال/الإخراج, compact unit

Pluto B46 v2 (2TLA020070R1700): 46 نقاط الإدخال/الإخراج, high-density model

ملحوظة: B46 v2 denotes hardware version v2. Older-revision B46 has a different order number; programs are compatible for migration.

Related Accessories

  1. Programming cable: Pluto USB programming cable
  2. بوابات: GATE-P2 (بروفيبوس), GATE-EIP (EtherNet-IP) for connection to standard PLC hosts
  3. برمجة: Pluto Manager (available for download from ABB official website)

Spare-Unit / Second-Hand Unit Inspection Checklist

  1. Power-on test and verify status LED operation for all channels
  2. Read firmware revision to confirm v2 hardware variant
  3. Complete program upload-download functional test
  4. Perform load-based switching test on relay outputs
  5. Inspect terminals for burn marks and backplane for corrosion

ABB Pluto B46 v2 (2TLA020070R1700) Programming Manual Key Content

الأجهزة: Pluto B46 v2; Software Tool: Pluto Manager (free download via ABB website)

Official full-reference document: Pluto Safety-PLC Programming manual, Doc. ID: 2TLC172002M0218 (English original; no complete official Chinese translation)

📘 Table-of-Contents Summary (Official Programming Manual)

  1. Safety precautions (safety-logic review; mandatory full-machine testing; software cannot detect logical errors)
  2. Pluto Manager installation, DEMO mode, license activation
  3. Complete new-project workflow
  4. Hardware I-O configuration (B46-v2-specific 46-point I-O definition)
  5. Addressing and symbolic naming of variables
  6. Ladder-logic programming + TÜV-certified safety function-block library
  7. Registers, system registers, analog signal processing
  8. Pluto-Safety-Bus multi-master networking (الأعلى. 32 Pluto units)
  9. Program download, IDFIX program duplication, password protection
  10. Online monitoring, fault diagnostics, error codes
  11. Modbus-TCP communication, host-PLC interfacing via gateways
  12. Program examples, تحديث البرامج الثابتة, hardware compatibility notes

🛠️ B46 v2 Hardware I-O Configuration Mandatory Programming Settings

رقم الطلب: 2TLA020070R1700 Pluto B46 v2

أنا: 24 fixed fail-safe inputs

IQ: 16 multi-function channels, software-selectable: Failsafe Input / Non-safe Output

ريال قطري: 4 independent safety relay outputs (سيل3/بل)

QT: 2 independent safety transistor outputs (سيل3/بل)

IQ channel operating mode must be defined in the Pluto Manager hardware configuration page. Mismatch between wiring and software configuration triggers hardware faults.

🔧 Standard Development Workflow in Pluto Manager

  1. Create new project, select hardware type `Pluto B46 v2`, assign Safety-Bus station address
  2. Configure I-O parameters

I-inputs: Dynamic / static input mode (static for light-curtain OSSD signals; dynamic for dual-channel E-stop and safety-gate circuits)

IQ channels: Individually set as Failsafe Input or Non-safe Output

  1. Symbolic variable assignment: I-input, Q-output, M-retentive memory, GM-global memory (bus-shared), R-registers
  2. LD ladder-logic programming: invoke TÜV-certified safety function-blocks (أوقف, safety gate, التحكم باليدين, light-curtain muting, safe speed monitoring)
  3. Compile project, resolve errors, assign program password
  4. Download program via USB cable. For multi-unit networks, programs are automatically distributed over Pluto-Safety-Bus to all stations
  5. Online monitoring: Forced-signal testing permitted only during commissioning, followed by complete machine safety validation
  6. خياري: IDFIX-PROG hardware program copy module for spare-unit replacement without a PC

📦 Frequently Used TÜV-Certified Safety Function Blocks

Function Blockطلب
Block 1‑2Dual‑channel E‑stop (with reset and line‑fault detection)
Block4‑5Safety‑gate monitoring
Block16Two‑hand control
Block18‑19Light‑curtain muting
Block28‑29Safe encoder, سرعة / مراقبة الموقف
Safety Timer (safe off‑delay)SIL3‑compliant safety delay; standard general‑purpose timers shall NOT be used for safety logic

⚠️ Critical Safety Programming Constraints

  1. Safety-related functions must use TÜV-certified function blocks. Implementing safety logic purely with generic ladder logic voids SIL3/PLe compliance.
  2. IQ configured as outputs are non-safe outputs and shall not be used for safety-related load disconnection. Safety cut-off must use QR relay outputs or QT transistor outputs.
  3. Pluto-Bus operates in all-master architecture. Each controller controls its local outputs; GM global memory handles cross-unit data exchange.
  4. Program download requires password. DEMO mode permits project viewing only; compilation and download functions are disabled.
  5. Spare-unit replacement: Program can be downloaded via USB, or duplicated rapidly using IDFIX-PROG module.

📑 Related Manual List

Manual TitleDocument IDغاية
Pluto Programming Manual2TLC172002M0218Core programming reference
Pluto Hardware Manual2TLC172001M0112Hardware wiring instructions
Gateway Manual2TLC172003MxxxxModbus‑TCP / بروفيبوس / EtherNet‑IP gateway documentation

💻 Software Download

Pluto Manager: Free download from ABB official website under low-voltage safety products. Match firmware revision; B46 v2 requires compatible v2-series firmware.

❗ Brief Fault-Code Reference (B46 v2)

Er20: No user program present

Er24: Program error

Er31: IDFIX program mismatch

Er4x: I-O channel fault (dynamic-input open-circuit / ماس كهربائى)

Pluto Manager OS Compatibility (for Pluto B46 v2)

Windows-only platform. No native MacOS or Linux releases. مرجع: Programming Manual Doc. ID 2TLC172002M0218

✅ Officially Validated & المدعومة (مُستَحسَن)

  1. ويندوز 7 SP1 (32-قليل / 64-قليل) احترافي / Enterprise / Ultimate
  2. ويندوز 10 (32-قليل / 64-قليل) احترافي / Enterprise (most widely-used for industrial commissioning)

For B46 v2 hardware, use recent Pluto-Manager releases; Windows 10-64-bit is preferred.

⚠️ Functional but NOT Officially Validated (field-proven, no manufacturer warranty coverage)

ويندوز 8 / ويندوز 8.1 (32-قليل / 64-قليل)

Windows Server 2008R2 / 2012 / 2012R2 / 2016 / 2019

ويندوز 11: Installs and operates in real-world deployments. USB communication may require compatibility-mode adjustments. Not listed within ABB official support matrix. ويندوز 10 remains preferred for site commissioning.

❌ Not Recommended / Unsupported

  1. Windows Vista: Installation possible, insufficient security components, not recommended
  2. Windows XP and earlier: Cannot run
  3. Mac OS, لينكس: No native builds; operation only via Windows virtual machine (VMware / VirtualBox)

📋 Software Dependencies (installed automatically; missing components cause runtime errors)

  1. Microsoft .NET Framework 4.6.1
  2. Visual C++ 2005, 2010 Runtime Libraries

🖥️ Minimum Hardware Requirements

وحدة المعالجة المركزية: 1 GHz or higher (x86/x64)

كبش: 2 GB (32-قليل) /3 GB (64-قليل)

HDD: 3 GB free storage space

💡 Practical Operation Notes

  1. ويندوز 11 عملية: If USB programming-cable communication fails, right-click application shortcut, enable compatibility mode for Windows 8 and run as administrator.
  2. DEMO mode: No license key required. Program download and online monitoring functions require valid license.
  3. Software-hardware matching: Pluto Manager version ≥ V14. Older software revisions cannot recognize v2 hardware.