ABB ACS550-01-031A-4 Variable Frequency Drive (VFD)
This is an ABB ACS550 series three-phase VFD, rated 15kW (Normal Duty) / 11كيلوواط (Heavy Duty), with nominal output current 31A. It is designed for 380-480V power grid, wall-mounted (IP21) enclosure, built-in vector control and EMC filter. Suitable for general industrial applications such as pumps, fans and conveyors.
- Model Breakdown Definition
| شريحة | شفرة | وصف |
| Series ID | ACS550 | ABB standard low-voltage AC drive series for general-purpose applications |
| نوع الهيكل | 1 | Wall-mounted construction (IP21 protection rating), for standard industrial environments |
| التصنيف الحالي | 031أ | Nominal continuous output current 31A; corresponds to 15kW for normal duty / 11kW for heavy duty |
| فئة الجهد | 4 | Suitable for three-phase 380-480V AC input power (+10/-15% voltage fluctuation tolerance) |
Product ID: 3AUA0000002418-D
حجم الإطار: R3
- Core Specification Parameter Table
| فئة | المعلمة | تصنيف | ملاحظات |
| Basic Ratings | Rated Output Current (I₂N) | 31أ | Continuous operation at 40℃ ambient |
| Normal Duty Power | 15كيلوواط | Standard 400V operating condition | |
| Heavy Duty Power | 11كيلوواط | Standard 400V operating condition | |
| Overload Capability | 1.1×I₂N (1 minute per 10 دقائق) | For normal duty; 1.5×I₂hd for heavy duty | |
| الخصائص الكهربائية | Input Voltage | 3-phase 380-480V | Input frequency: 48-63هرتز |
| الجهد الناتج | 3-مرحلة 0 ~ Input Voltage | Output frequency: 0-500هرتز | |
| Control Mode | مكافحة ناقلات الأمراض (Open-loop / Closed-loop) | Open-loop accuracy: 20% motor slip; Closed-loop accuracy: 0.1% of rated speed | |
| Switching Frequency | 4kHz (Default) | خياري: 1/2/4/8/12kHz | |
| I/O Interface | المدخلات التناظرية | 2 القنوات (0-10V / 4-20أماه) | Input impedance: الجهد االكهربى >312kΩ, Current 100Ω |
| الإخراج التناظري | 2 القنوات (4-20أماه) | Max load <500أوه, Accuracy ±3% | |
| الإدخال الرقمي | 6 القنوات | 24في العاصمة, PNP/NPN compatible | |
| تتابع الإخراج | 3 القنوات | Max 250V AC / 30في العاصمة, Switching current 6A | |
| واجهة الاتصالات | Built-in RS485 (مودبوس) | Support expansion of multiple fieldbuses | |
| الخصائص البدنية | فئة الحماية | IP21 | التكوين القياسي; IP54 optional |
| أبعاد (العرض × الارتفاع × العمق) | 270×600×450mm | R3 frame size | |
| وزن | تقريبا. 20.5كجم | Basic configuration included | |
| Heat Dissipation | 457دبليو | Air flow: 134م³/ساعة | |
| Environmental Limits | درجة حرارة التشغيل | -15℃ ~ 50℃ | Derating required above 40-50℃ |
| ارتفاع | 0-1000م (Full rating) | ديراتي 1% per 100m elevation increase | |
| رطوبة | 5-95% (Non-condensing) | متوافق مع IEC 721-3-3 |
- الملحقات القياسية & Optional Parts List
3.1 Standard Supplied Accessories
Assistant Control Panel (ACS-CP-D), with real-time clock and parameter modification record function
Built-in Class C2 EMC Filter (First Environment), meets basic EMC requirements
Mounting template for quick drilling position marking
Product manual and quick start guide
Standard I/O terminals and Modbus communication interface
3.2 Recommended Optional Parts
| يكتب | نموذج | وصف الوظيفة | سيناريو التطبيق |
| Control Panel | ACS-CP-C | Advanced control panel with parameter copy and multi-language support | التكليف & batch configuration for multiple VFDs |
| Braking Unit | ACS-BRK-D | Brake chopper + resistor (10.5, 7كيلوواط) | Frequent start-stop / fast deceleration applications |
| مفاعل | LOCH0030-60 | Output reactor (41أ) | Suppress dv/dt when motor cable length >200م |
| وحدة الاتصالات | Various Fieldbus | Profibus DP / ديفيس نت / إيثرنت/IP | Connection to PLC control system |
| Encoder Module | خياري | Speed feedback to improve closed-loop control accuracy | High-precision speed control applications |
| Extended I/O | خياري | Additional 3 مخرجات التتابع | Multi-status monitoring & control requirements |
- Cross-Brand Alternative Comparison Table
| ماركة | مسلسل | Equivalent Model | Key Parameter Matching | وصف الفرق |
| شنايدر | ألتيفار 610 | ATV610U15N4 | 15kW/31A/380-480V | Built-in PLC with higher integration |
| سيمنز | SINAMICS G120C | 6SL3210-1PE21-8UL0 | 15kW/31A/380-480V | Modular design with strong expandability |
| ميتسوبيشي | FR-A840 | FR-A840-15K-NA | 15kW/31A/380-480V | High vector control accuracy, مناسبة للأحمال المعقدة |
| دانفوس | VLT 2800 | 2840PT37T20H | 15kW/31A/380-480V | فعالة من حيث التكلفة, ideal for fan & pump applications |
| ABB Alternative | ACS510 | ACS510-01-031A-4 | 15kW/31A/380-480V | Simplified version for fan/pump, without vector control |
- إرشادات الاختيار & الحلول البديلة
5.1 Core Selection Principles
Current Priority: VFD rated current ≥ 1.1~1.3 times motor rated current, do not select only by power rating
مطابقة التحميل:
واجب عادي (Pump/Fan): Standard selection 15kW/31A
واجب ثقيل (Compressor/Crusher): Recommend upgrade to 18.5kW (ACS550-01-038A-4) or higher frame
التكيف البيئي:
درجة حرارة >40درجه مئوية: Derate 5~10% per 5℃ rise
ارتفاع >1000م: ديراتي 1% per 100m rise
Dust environment: Select IP54 protection grade model
5.2 Recommended Alternative Solutions
| سيناريو التطبيق | Recommended Solution | وصف الميزة |
| Standard General Purpose | ACS550-01-031A-4 | Built-in vector control, أداء عالي التكلفة |
| معجب & Pump Dedicated | ACS510-01-031A-4 | Energy-saving optimized algorithm, تكلفة أقل |
| High Precision Control | ACS550-01-031A-4 + Encoder Module | Closed-loop control, speed accuracy up to 0.1% |
| Heavy Duty Frequent Start-Stop | ACS550-01-038A-4 + ACS-BRK-D | Higher power margin + braking assembly, عمر خدمة أطول |
| Cost-Sensitive Project | Schneider ATV320U15N4 | حجم صغير, competitive price |
5.3 تثبيت & النقاط الرئيسية للصيانة
Cooling clearance reserved: 200mm top and bottom, no special requirement for left and right sides
Input protection: Recommended 35A gG fuse (UL Class T 40A)
Motor cable: Standard length ≤200m; install output reactor for longer distance
Maintenance cycle: Inspect cooling fan and capacitor condition after 10,000 operating hours
- ACS550 Series Full Power Model List (R3 Frame Size)
| نموذج | التصنيف الحالي | Normal Duty Power | Heavy Duty Power | سيناريو التطبيق |
| ACS550-01-031A-4 | 31أ | 15كيلوواط | 11كيلوواط | Standard general load |
| ACS550-01-038A-4 | 38أ | 18.5كيلوواط | 15كيلوواط | واجب ثقيل / Frequent start-stop |
| ACS550-01-045A-4 | 45أ | 22كيلوواط | 18.5كيلوواط | High-power general load |
The ACS550-01-031A-4 is a cost-effective general-purpose vector VFD, suitable for 15kW normal duty / 11kW heavy duty loads. With rich built-in functions and interfaces, it is widely used in general machinery requiring high control accuracy and reliability in industrial automation. Prioritize motor current matching during selection, and determine expansion modules or power upgrade according to load type and ambient conditions.
Complete Full Range Model List of ABB Variable Frequency Drives (Structured Version)
- Quick Overview of Model Naming Rules
ABB VFD adopts standard format: ACSxxx-xx-xxxX-xx, definition of each segment as below:
| شريحة | معنى | مثال | وصف |
| ACSxxx | كود السلسلة | ACS550/510/880 | Product positioning & application category |
| -xx | كود الهيكل | 01/04/31 | 01=Wall-mounted IP21; 04=Cabinet-type IP21; 31=Wall-mounted IP54 |
| -xxxX | التصنيف الحالي | 031A/125A | Numeric + letter for output current; A = Standard type |
| -xx | فئة الجهد | 2004/2/7 | 4=380-480V 3-phase; 2=200-240V 3-phase; 7=500-690V 3-phase |
- Main Series Overview (Sorted by Power Range)
| مسلسل | تحديد المواقع | نطاق الطاقة | Typical Application | سمات |
| ACS150 | Economy Micro Drive | 0.37-4كيلوواط | Small pumps, المشجعين, rolling shutters | Single/3-phase universal, simple operation, IP20/IP21 |
| ACS355 | Compact General Drive | 0.37-15كيلوواط | ماكينات التعبئة والتغليف, small conveyors | Built-in brake chopper, wide voltage range |
| ACS510 | معجب & Pump Dedicated | 0.75-160كيلوواط | Constant pressure water supply, cooling fan, التدفئة والتهوية وتكييف الهواء | Energy-saving optimized algorithm, built-in PID, low cost |
| ACS550 | Enhanced General Drive | 0.75-355كيلوواط | الضواغط, الناقلات, خلاطات | مكافحة ناقلات الأمراض, strong heavy-duty capability, المدمج في إي إم سي |
| ACS580 | New Generation General Machinery Drive | 0.75-500كيلوواط | All kinds of industrial loads | Integrated safety functions, تصميم وحدات, intelligent connection |
| ACS880 | Flagship High-Performance Drive | 0.75-2500كيلوواط | تحكم عالي الدقة, complex machinery | Full compatibility, موثوقية عالية, built-in safety functions |
| ACH550 | HVAC Dedicated | 0.75-355كيلوواط | Air conditioning & أنظمة التهوية | Building control protocol, comfort control algorithm |
- Detailed Model List by Series
3.1 ACS550 Series (Enhanced General Drive, IP21 Wall-mounted, 380-480الخامس 3 مراحل)
| نموذج | التصنيف الحالي | Normal Duty Power | Heavy Duty Power | حجم الإطار | رمز الطلب |
| ACS550-01-003A-4 | 3أ | 0.75كيلوواط | 0.55كيلوواط | R1 | 3AUA0000002415-D |
| ACS550-01-004A-4 | 4أ | 1.1كيلوواط | 0.75كيلوواط | R1 | 3AUA0000002416-D |
| ACS550-01-006A-4 | 6أ | 1.5كيلوواط | 1.1كيلوواط | R1 | – |
| ACS550-01-009A-4 | 9أ | 4كيلوواط | 3كيلوواط | R1 | – |
| ACS550-01-012A-4 | 12أ | 5.5كيلوواط | 4كيلوواط | R1 | – |
| ACS550-01-015A-4 | 15أ | 7.5كيلوواط | 5.5كيلوواط | R2 | – |
| ACS550-01-019A-4 | 19أ | 11كيلوواط | 7.5كيلوواط | R2 | – |
| ACS550-01-023A-4 | 23أ | 11كيلوواط | 10كيلوواط | R2 | 3AUA0000002417-D |
| ACS550-01-031A-4 | 31أ | 15كيلوواط | 11كيلوواط | R3 | 3AUA0000002418-D |
| ACS550-01-038A-4 | 38أ | 18.5كيلوواط | 15كيلوواط | R3 | – |
| ACS550-01-045A-4 | 45أ | 22كيلوواط | 18.5كيلوواط | R3 | – |
| ACS550-01-057A-4 | 57أ | 30كيلوواط | 22كيلوواط | R4 | – |
| ACS550-01-072A-4 | 72أ | 37كيلوواط | 30كيلوواط | R4 | – |
| ACS550-01-09A4-4 | 94أ | 45كيلوواط | 37كيلوواط | R5 | – |
| ACS550-01-125A-4 | 125أ | 55كيلوواط | 45كيلوواط | R5 | 3ABD68589657 |
| ACS550-01-157A-4 | 157أ | 75كيلوواط | 55كيلوواط | R6 | – |
| ACS550-01-180A-4 | 180أ | 90كيلوواط | 75كيلوواط | R6 | – |
| ACS550-01-210A-4 | 210أ | 110كيلوواط | 90كيلوواط | R7 | – |
| ACS550-01-250A-4 | 250أ | 132كيلوواط | 110كيلوواط | R7 | – |
| ACS550-01-290A-4 | 290أ | 160كيلوواط | 132كيلوواط | R8 | – |
| ACS550-01-340A-4 | 340أ | 185كيلوواط | 160كيلوواط | R8 | – |
| ACS550-01-400A-4 | 400أ | 200كيلوواط | 185كيلوواط | R9 | – |
3.2 ACS510 Series (معجب & Pump Dedicated, IP21 Wall-mounted, 380-480الخامس 3 مراحل)
| نموذج | التصنيف الحالي | قوة | حجم الإطار |
| ACS510-01-003A3-4 | 3.3أ | 1.1كيلوواط | R1 |
| ACS510-01-004A1-4 | 4.1أ | 1.5كيلوواط | R1 |
| ACS510-01-005A6-4 | 5.6أ | 2.2كيلوواط | R1 |
| ACS510-01-007A2-4 | 7.2أ | 3كيلوواط | R1 |
| ACS510-01-009A4-4 | 9.4أ | 4كيلوواط | R1 |
| ACS510-01-012A5-4 | 12.5أ | 5.5كيلوواط | R1 |
| ACS510-01-015A6-4 | 15.6أ | 7.5كيلوواط | R2 |
| ACS510-01-019A0-4 | 19.0أ | 11كيلوواط | R2 |
| ACS510-01-024A1-4 | 24.1أ | 15كيلوواط | R3 |
| ACS510-01-030A8-4 | 30.8أ | 18.5كيلوواط | R3 |
| ACS510-01-038A0-4 | 38.0أ | 22كيلوواط | R3 |
| ACS510-01-045A0-4 | 45.0أ | 30كيلوواط | R4 |
| ACS510-01-057A0-4 | 57.0أ | 37كيلوواط | R4 |
| ACS510-01-072A0-4 | 72.0أ | 45كيلوواط | R5 |
| ACS510-01-09A4-4 | 94.0أ | 55كيلوواط | R5 |
3.3 ACS880 Series (Flagship High-End Drive, Partial Models)
| نموذج | نوع الهيكل | التصنيف الحالي | قوة | فئة الجهد | سمات |
| ACS880-01-003A-4 | Wall-mounted IP21 | 3أ | 0.75كيلوواط | 380-480V | Compact type |
| ACS880-01-031A-4 | Wall-mounted IP21 | 31أ | 15كيلوواط | 380-480V | مكافحة ناقلات الأمراض |
| ACS880-31-145A-3 | Wall-mounted IP54 | 145أ | 75كيلوواط | 380-480V | مقاوم للغبار & ضد للماء |
| ACS880-04-271A-7 | Cabinet-type IP21 | 271أ | 160كيلوواط | 500-690V | كثافة طاقة عالية |
| ACS880-07-0450A-7 | Cabinet-type IP21 | 450أ | 315كيلوواط | 500-690V | تصميم وحدات |
3.4 Selected Models of Other Common Series
| مسلسل | نموذج | قوة | الجهد االكهربى | طلب |
| ACS355 | ACS355-03E-04A7-4 | 1.5كيلوواط | 380-480V | Small machinery |
| ACS355-03E-12A5-4 | 5.5كيلوواط | 380-480V | Packaging equipment | |
| ACS150 | ACS150-03E-03A3-4 | 1.1كيلوواط | 380-480V | Small pumps |
| ACS150-01E-02أ4-2 | 0.75كيلوواط | 200-240V | Single-phase power supply | |
| ACH550 | ACH550-01-031A-4 | 15كيلوواط | 380-480V | HVAC system |
| ACH550-01-125A-4 | 55كيلوواط | 380-480V | Large air conditioning | |
| ACS580 | ACS580-01-04A5-4 | 2.2كيلوواط | 380-480V | الآلات العامة |
| ACS580-01-320A-4 | 160كيلوواط | 380-480V | Heavy-duty load |
- ملاحظات الاختيار الرئيسية
- Current Priority Principle: VFD rated current ≥ 1.1~1.3 times motor rated current; do not select merely by power rating.
- مطابقة نوع التحميل:
معجب / Pump: Choose ACS510 / ACS380 for better energy saving
Constant torque / واجب ثقيل: Choose ACS550 / ACS880 for stronger overload capability
HVAC dedicated: Choose ACH550 with built-in building control protocol
- التكيف البيئي:
Dust environment: Select IP54 protection grade (على سبيل المثال. ACS880-31 series)
High temperature environment: Derating required above 40℃, derate 5~10% per 5℃ rise
ارتفاع >1000م: ديراتي 1% per 100m elevation increase
- Model Extension Rules
Basic model can be extended with +option code for additional functions, examples:
ACS550-01-031A-4+J400: Add Profibus DP communication module
ACS550-01-031A-4+K454: Add brake chopper
ACS550-01-031A-4+L501: Add output reactor
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية





















NH42-63-318x560.png)