Technical File for ABB ACS550-01-290A-4 (132-160KW)
- تفسير النموذج
| Model Segment | وصف |
| ACS550 | ABB Standard General-Purpose Inverter Series |
| 1 | Wall-mounted Installation, Power Range 1.1-160kW |
| 290أ | Rated Output Current (Light Duty/Fans & Pumps Application) |
| 4 | Voltage Class: 380-480V Three-phase AC |
| 132KW | Heavy Duty (HD) Rated Power (246أ, 150% Overload for 1 Minute) |
| 160KW | Light Duty (LD) Rated Power (290أ, 110% Overload for 1 Minute) |
- Core Electrical Parameters
| Parameter Item | Light Duty (LD)/Fans & Pumps | Heavy Duty (HD)/Constant Torque |
| Rated Power | 160KW | 132KW |
| Rated Output Current | 290أ | 246أ |
| Input Voltage | 380-480V, ثلاث مراحل, 50/60هرتز (卤10%) | Same as Left |
| Output Voltage | 0 to Input Voltage, ثلاث مراحل | Same as Left |
| Output Frequency | 0-500هرتز | Same as Left |
| Overload Capacity | 110% of Rated Current for 1 Minute | 150% of Rated Current for 1 Minute |
| Power Factor | 0.98 (Output) | Same as Left |
| Efficiency | تقريبًا 97% | Same as Left |
- Physical & Installation Parameters
طريقة التركيب: Wall-mounted (IP21 Standard Protection)
أبعاد: R6 Size, Approximately 302mm (Width) × 400mm (Depth) × 860mm (Height)
وزن: Approximately 80kg
Cooling Method: Forced Air Cooling
فئة الحماية: IP21 (Standard), IP54 Protection Kit Optional
- Control Characteristics
- Control Modes:
V/f Scalar Control
Sensorless Vector Control (SVC), Enabling High Starting Torque (150% Torque at 0.5Hz)
- Speed Control Accuracy: ±0.5% of Rated Synchronous Speed (Sensorless Vector Control)
- Frequency Resolution: 0.01Hz for Digital Setting, 0.06Hz for Analog Setting
- Acceleration/Deceleration Time: Adjustable from 0.1 ل 1800 Seconds
- Built-in Functions:
Built-in EMC Filter (Class C2)
Built-in Modbus RTU Communication Interface
Patented Swinging Choke for Optimized Harmonic Suppression
Built-in PID Controller, Suitable for Closed-loop Process Control
Energy-saving Calculator, Real-time Display of Energy Savings
- سيناريوهات التطبيق
Light Duty Applications: Fans, Water Pumps, Cooling Towers, Ventilation Systems (160KW, 290أ)
Heavy Duty Applications: Conveyor Belts, Mixers, Compressors, Crushers (132KW, 246أ)
Applicable Industries: General Industrial Sectors such as HVAC, Water Treatment, Manufacturing, Mining, Building Materials, إلخ.
- Key Function Highlights
- Harmonic Suppression: Built-in Swinging Choke, Compliant with IEEE 519 Standard, Reducing Grid Harmonic Interference
- القدرة على التكيف البيئي:
درجة حرارة التشغيل: -10℃ to +40℃ (Derating Required for 40-50℃)
Humidity: 5-95% RH, No Condensation
Altitude: ≤1000m (1% Derating per 100m Above 1000m)
- وظائف الحماية:
Overcurrent, الزائد, Overvoltage, انخفاض الجهد, Overheating Protection
Motor Overheating Protection (PTC/PID)
Short-circuit Protection, Earth Fault Protection
Phase Loss Protection, Motor Stall Protection
- Replacement & Upgrade Solutions
- Direct Replacement Models:
ABB ACS580-01-290A-4 (Next-generation Standard Inverter with Enhanced Functions)
Schneider ATV61HD160N4 (160KW, Heavy Duty)
Siemens MM440-250A (132KW, Heavy Duty) / MM440-290A (160KW, Light Duty)
- Upgrade Suggestion: The ACS580 Series Offers Higher Efficiency, Richer Communication Protocols, and More Comprehensive Safety Functions
- تثبيت & النقاط الرئيسية للصيانة
- متطلبات التثبيت:
Vertical Mounting, Minimum 150mm Clearance on Left & Right Sides, 200mm on Top, 100mm at Bottom
Clean, Dry Environment Free of Corrosive Gases
Reliable Earthing Required (Earthing Resistance ≤4Ω)
- مواصفات الأسلاك:
Main Circuit Cables: Copper Core Cables for Both Input & Output, Cross-sectional Area ≥95mm² (Adjust According to Cable Length)
دائرة التحكم: Shielded Cables, Routed Separately from Main Circuit (≥100mm Separation)
- دورة الصيانة:
Daily: Check Operating Status, Cooling Fans, Clean Air Filters (Every 3-6 Months)
Annual: Inspect Main Circuit Terminal Tightness, Capacitor Condition, Insulation Testing
5-Year: Recommended Replacement of Cooling Fans and Electrolytic Capacitors
- Common Fault Codes & استكشاف الأخطاء وإصلاحها
| Fault Code | Meaning | Troubleshooting Method |
| FA001 | Overcurrent | Check Motor Load, Insulation, Output Cables; Adjust Acceleration Time |
| FA002 | Overvoltage | Check Grid Voltage; Adjust Deceleration Time; Install Brake Resistor |
| FA003 | انخفاض الجهد | Check Input Voltage; Verify Power Supply Stability |
| FA004 | Overheating | Clean Heat Dissipation Channels; Inspect Fans; Reduce Ambient Temperature |
| FA005 | Motor Overload | Reduce Load; Check Motor Parameter Settings; Extend Acceleration Time |
- Ordering & Accessories
Standard Configuration: Inverter Unit, Operation Panel (ACS-CP-D), Installation Manual, Warranty Card
Optional Accessories:
Remote Operation Panel (ACS-CP-D) and Extension Cable
Brake Unit & Brake Resistor (Suitable for Frequent Start/Stop or Rapid Deceleration)
Input/Output Reactors (Enhanced Harmonic Suppression)
IP54 Protection Kit
Communication Extension Modules (Profibus DP, DeviceNet, EtherNet/IP, إلخ.)
Comparison & Analysis of ABB ACS550-01-290A-4 vs. ACS550-01-290A-5
- Core Finding: Model Validity Statement
Important Conclusion: The model “ACS550-01-290A-5” does not exist in the official ABB ACS550 product lineup. The standard voltage class suffixes for ABB ACS550 inverters are only three types:
2 = 208-240V Three-phase AC
4 = 380-480V Three-phase AC (The Model Mentioned by the User)
6 = 500-600V Three-phase AC
It is inferred that the user may have confused the suffix “4” (380-480V) with other series, or mistyped “6” (500-600V) as “5”. The following content will focus on comparing ACS550-01-290A-4 (380-480V) with ACS550-01-290A-6 (500-600V, the correct high-voltage version), while explaining the non-existence of the suffix “5”.
- Complete Model Interpretation
| Model Segment | ACS550-01-290A-4 | ACS550-01-290A-6 | وصف |
| ACS550 | Standard General-Purpose Inverter Series | Standard General-Purpose Inverter Series | Identical |
| 1 | Wall-mounted Installation, Power Range 1.1-160kW | Wall-mounted Installation, Power Range 1.1-160kW | Identical |
| 290أ | Rated Output Current (Light Duty/Fans & Pumps Application) | Rated Output Current (Light Duty/Fans & Pumps Application) | Identical |
| 4月6日 | Voltage Class: 4=380-480V, 6=500-600V | Voltage Class: 4=380-480V, 6=500-600V | Core Difference |
| Light Duty Power | 160KW (290أ, 110% Overload for 1 Minute) | 160KW (290أ, 110% Overload for 1 Minute) | Identical |
| Heavy Duty Power | 132KW (246أ, 150% Overload for 1 Minute) | 132KW (246أ, 150% Overload for 1 Minute) | Identical |
- Detailed Comparison Between ACS550-01-290A-4 and ACS550-01-290A-6 (Correct High-voltage Version)
3.1 Core Differences in Electrical Parameters
| Parameter Item | ACS550-01-290A-4 (380-480V) | ACS550-01-290A-6 (500-600V) | Impact |
| Input Voltage Range | 380-480V Three-phase, 50/60هرتز (10%) | 500-600V Three-phase, 50/60هرتز (卤10%) | Adapts to Different Grid Systems |
| Output Voltage Range | 0 to Input Voltage, ثلاث مراحل | 0 to Input Voltage, ثلاث مراحل | Must Match Motor Rated Voltage |
| Rated Power | 160KW (LD) / 132KW (HD) | 160KW (LD) / 132KW (HD) | Identical (Same Current, Higher Voltage) |
| التصنيف الحالي | 290أ (LD) / 246أ (HD) | 290أ (LD) / 246أ (HD) | Identical |
| Power Factor | 0.98 (Output) | 0.98 (Output) | Identical |
| Efficiency | تقريبًا 97% | تقريبًا 97% | Identical |
| Maximum Output Frequency | 0-500هرتز | 0-500هرتز | Identical |
3.2 Physical & Application Differences
| Item | ACS550-01-290A-4 | ACS550-01-290A-6 | وصف |
| أبعاد | R6: 302mm*400mm*860mm | R6: 302mm*400mm*860mm | Identical (Same Size for Same Current Class) |
| وزن | Approximately 80kg | Approximately 80kg | Identical |
| فئة الحماية | IP21 Standard, IP54 Optional | IP21 Standard, IP54 Optional | Identical |
| Cooling Method | Forced Air Cooling | Forced Air Cooling | Identical |
| Applicable Motors | 380-480V Three-phase Asynchronous Motors | 500-600V Three-phase Asynchronous Motors | Motor Voltage Must Match |
| التطبيقات النموذجية | General Industry, التدفئة والتهوية وتكييف الهواء, Water Treatment | Heavy Industry, Mining, Special Grid Regions | Adapts to Regional Grid Standards |
| EMC Filter | Built-in Class C2 Filter | Built-in Class C2 Filter | Identical |
| Communication Functions | Built-in Modbus RTU | Built-in Modbus RTU | Identical |
3.3 Key Functional & Protection Differences
| وظيفة | ACS550-01-290A-4 | ACS550-01-290A-6 | Remarks |
| Control Modes | V/f Scalar Control, Sensorless Vector Control (SVC) | V/f Scalar Control, Sensorless Vector Control (SVC) | Identical |
| Starting Torque | 150% Rated Torque at 0.5Hz | 150% Rated Torque at 0.5Hz | Identical |
| وظائف الحماية | Overcurrent, الزائد, Overvoltage, انخفاض الجهد, Overheating, Short-circuit, Earth Fault, إلخ. | Overcurrent, الزائد, Overvoltage, انخفاض الجهد, Overheating, Short-circuit, Earth Fault, إلخ. | Identical, but Protection Thresholds Adapt to Corresponding Voltage Classes |
| Harmonic Suppression | Built-in Swinging Choke | Built-in Swinging Choke | Identical, Compliant with IEEE 519 Standard |
- توصيات الاختيار
- Confirm Voltage Class: Select the correct suffix (2/4/6) according to on-site grid and motor rated voltage. Avoid using the non-standard suffix “5”.
- مطابقة الطاقة: Choose 160kW for light-duty applications (المشجعين & مضخات) and 132kW for heavy-duty applications (constant torque), corresponding to currents of 290A and 246A respectively.
- Replacement Options: For higher voltage or function upgrades, consider:
Correct voltage model in the same series: ACS550-01-290A-6 (500-600V)
Next-generation product: ACS580-01-290A-4 (380-480V) or ACS580-01-290A-6 (500-600V), which provide higher efficiency, richer communication protocols and more comprehensive safety functions.
- ملخص
The model ACS550-01-290A-5 is invalid in the ABB ACS550 series, and the official only provides three voltage suffixes: 2, 4, و 6. What the user actually needs may be:
Standard 380-480V version: ACS550-01-290A-4 (132-160KW)
High-voltage 500-600V version: ACS550-01-290A-6 (132-160KW)
The core difference between the two models lies only in the input/output voltage class, while other functional parameters (حاضِر, power, control mode, protection functions, إلخ.) are completely identical. During model selection, strict matching with on-site grid and motor parameters is required.
| Model | technical specifications | unit | quantity | unit price |
| PLC CPU | Manufacturer: سيمنز Model: ST60 Protection degree: IP20 Voltage: 24V 6ES7288-1ST60-0AA1/0AA0 | pcs | 1 | ¥1,350.00 |
| PLC CPU | Manufacturer: سيمنز Model: SR30 Protection degree: IP20 Voltage: 24V | pcs | 1 | ¥750.00 |
| Digital input/ouput | Manufacturer: Siemens EM DR32 Type: Digital I/O Module Input: 16 العاصمة, 24V Output: 16 relays 2A 6ES7288-2DR32-0AA0 | pcs | 1 | ¥755.00 |
| Digital input/ouput | Manufacturer: سيمنز Model: سيمنز, DE16 Input: 16 digital inputs, 24V وزن: 0.2كجم 6ES7288-2DE16-0AA0 | pcs | 1 | ¥530.00 |
| Analog input/Output module | Manufacturer: سيمنز Model: EM AM03 Input: 2 input analog channels Output: 1 output analog channel 6ES7288-3AM03-0AA0 | pcs | 1 | ¥620.00 |
| Communication module | Manufacturer: سيمنز Model: EM DP01 profibus DP slave module Speed: 9.6 KB to 12 ميغابايت Interface: PROFIBUS-DP/MPI 6ES7288-7DP01-0AA0 | pcs | 1 | ¥1,142.00 |
| Analog input/Output module | Manufacturer: سيمنز Model: EM AM06 Input/output: 4 analog inputs, 2 analog outputs وزن: 0.2كجم Signal type: 0…10 V, 0…5 V, 0/4…20أماه 6ES7288-3AM06-0AA0 | pcs | 1 | ¥922.00 |
| Digital input/ouput | Manufacturer: سيمنز, EM DT32 Input/output: 16 digital inputs, 16 digital outputs وزن: 0.2كجم Signal type: 0…10 V, 0…5 V, 0/4…20أماه Voltage input: 20-28V 6ES7288-2DT32-0AA0 | pcs | 1 | ¥942.00 |
| Smart analog module | Manufacturer: سيمنز, Model: SM AE08 analog input module Number of inputs: 8 Type: 0 … 10V, 0/4-20أماه 6ES7288-3AE08-0AA0 | pcs | 1 | ¥965.00 |
| Smart analog module | Manufacturer: سيمنز, Model: EM AE04 Number of inputs: 4 Type: 0/4-20أماه, 0-10V 6ES7288-3AE04-0AA0 | pcs | 1 | ¥512.00 |
| PLC CPU | Manufacturer: ايه بي بي, Model: PM5630 Operating voltage: 24VDC Ethernet port x 2 PM5630-2ETH | pcs | 1 | ¥8,850.00 |
| Digital input/output | Manufacturer: ايه بي بي Model: DC532 Operating voltage: 24V 16 digital transistor inputs | pcs | 1 | ¥2,750.00 |
| Analog input/output module | Manufacturer: ايه بي بي Model: AX521 D1 Number of inputs: 4 Input type: Current, Voltage 1SAP250100R0001 | pcs | 1 | ¥4,688.00 |
| Communication module | Manufacturer: ايه بي بي Model: CM582-DP Type: DP Profibus Serial Baud rate: 12000kbps 1SAP172200R0001 | pcs | 1 | ¥3,325.00 |
| Analog input | Manufacturer: سيمنز, Model: EM AE04 Number of inputs: 4 Type: 0/4-20أماه, 0-10V | pcs | 1 | ¥512.00 |
| Processor module | Manufacturer: ايه بي بي Model: PM573-ETH Voltage: 24V Connections: Ethernet, RS232, RS485,RS422 1SAP130300R0271 | pcs | 1 | ¥7,100.00 |
| Terminal base slot cover | Manufacturer: ايه بي بي Model: TA524 AC500 base 1SAP180600R0001 | pcs | 1 | ¥840.00 |
| Digital input module | Manufacturer: ايه بي بي Model: DI562 Number of inputs: 16 transistor digital , Input type: Sink/source Voltage: 24 تيار متردد/تيار مستمر 1TNE968902R2102 | pcs | 1 | ¥2,540.00 |
| Digital output module | Manufacturer: ايه بي بي Model: DO573 Number of outputs: 16 Output type: Relay | pcs | 1 | ¥1,981.00 |
| Аnalog input module | Manufacturer: ايه بي بي Model: AI561 Number of inputs and outputs: 4 AI, ش,I Connection type: Plug-in, 1TNE968902R1101 | pcs | 1 | ¥1,230.00 |
| Media converter | مواصفة: 1GBps Wavelength: TX1550nm, 1310nm Distance: Not less than 30km Connector: SC | pcs | 10 | ¥- |
| PROFIBUS Bus Connector | Manufacturer: سيمنز Model: 6ES7972-0BA12-0XA0 Connection: RS485 bus connection Country of manufacture: Germany | pcs | 5 | ¥210.00 |
| RS485 Repeater | Manufacturer: سيمنز Model: 6ES7972-0AA02-0XA0 Connection: RS 485 repeater for PROFIBUS Country of manufacture: Germany وزن: 0.2كجم | pcs | 4 | ¥2,600.00 |
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية





















NH42-63-318x560.png)



