ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

ABB VBC7-30-01220-240V DC Miniature Reversing Contactor - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

قواطع/

ABB VBC7-30-01220-240V DC Miniature Reversing Contactor

الجزء النموذجيوصف
ايه بي بيBrand Logo
VBC7Series Name: VBC7 Series Miniature Reversing Contactor (equipped with mechanical interlock, for motor forward and reverse rotation control)
30تكوين جهة الاتصال الرئيسية: 3-pole Normally Open (3لا)
1Auxiliary Contact Configuration: 1 Normally Closed (1نورث كارولاينا)
220-240V DCCoil Control Voltage: DC 220-240V
*Special Version Identifier (may be a customized or market-specific version)

  • تفاصيل المنتج
  1. تفسير النموذج
الجزء النموذجيوصف
ايه بي بيBrand Logo
VBC7Series Name: VBC7 Series Miniature Reversing Contactor (equipped with mechanical interlock, for motor forward and reverse rotation control)
30تكوين جهة الاتصال الرئيسية: 3-pole Normally Open (3لا)
1Auxiliary Contact Configuration: 1 Normally Closed (1نورث كارولاينا)
220-240V DCCoil Control Voltage: DC 220-240V
*Special Version Identifier (may be a customized or market-specific version)

Full Model: VBC7-30-01-05 (standard model, corresponding to 220-240V DC coil)

  1. المعلمات التقنية الأساسية
  2. المعلمات الكهربائية الأساسية
Parameter Itemقيمةملاحظات
Rated Current of Main Contacts16أ (ايه سي-3) / 20أ (ايه سي-1)ايه سي-3: Control of 5.5kW three-phase motor at 400V
تصنيف جهد التشغيل690الخامس ويتوافق مع اللجنة الانتخابية المستقلة 60947-4-1 معيار
Coil Control Voltage220-240V DCWide voltage range, allowing 卤15% fluctuation
Coil Power ConsumptionPick-up: تقريبا. 5دبليوDC coil operates with no noise or humming
Holding: تقريبا. 5دبليو
عمر الخدمة الميكانيكية10 مليون عمليةUnder standard operating conditions
عمر الخدمة الكهربائيةايه سي-1: 1 مليون عمليةUnder rated load
ايه سي-3: 100,000 العمليات
  1. Performance Indicators
Parameter ItemقيمةApplicable Conditions
التعشيق الميكانيكيBuilt-in reliable mechanical interlockPrevents simultaneous closing of forward and reverse contactors
Overvoltage ProtectionBuilt-in surge suppression diodeProtects coil and control circuit
Switch Position IndicationVisual position markingFacilitates fault diagnosis and status confirmation
Insulation ClassClass FComplies with IEC standards
Protection RatingIP20Must be installed inside control cabinet
  1. Environmental and Installation Parameters
Parameter ItemقيمةStandard/Remarks
درجة حرارة التشغيل-25℃~+60℃درجة حرارة التخزين: -40℃~+85℃
طريقة التركيب35mm DIN rail mounting / screw mountingSpace-saving and easy to integrate
نوع المحطةScrew terminalsSuitable for 22-10 AWG stranded wires
وزنتقريبا. 250زCompact design with light weight

ثالثا. الميزات الوظيفية

  1. Dedicated for Reversing Control: Built-in mechanical interlock ensures that forward and reverse contactors cannot be closed simultaneously, ensuring safety and reliability.
  2. Quiet Operation: DC coil design eliminates the humming noise common in AC contactors, enabling silent operation.
  3. Wide Voltage Adaptability: The coil supports a wide voltage range of 220-240V DC, adapting to different power supply conditions.
  4. Overvoltage Protection: Built-in surge suppression diode effectively protects the coil and control circuit from voltage spikes.
  5. إشارة الحالة: Clear switch position indication facilitates on-site operation and fault diagnosis.
  6. Flexible Installation: Supports both DIN rail and screw mounting methods, adapting to various control cabinet layouts.
  7. موثوقية عالية: With a mechanical service life of up to 10 million operations and long electrical service life, it is suitable for frequent operation scenarios.
  8. Application Scope
  9. التحكم في المحركات: Forward and reverse rotation control of three-phase asynchronous motors, مثل:

Small conveyors and hoists

Fans and pumps (requiring reversible operation)

Packaging machinery and printing machinery

  1. الأتمتة الصناعية:

Control of auxiliary equipment in production lines

Output actuator for small PLC control systems

Equipment interlock control circuits

  1. Commercial and Building Applications:

Fan control in air conditioning systems

Elevator door motors and small lifting platforms

Automatic door and rolling shutter door control

  1. Other Applications:

Control of battery-powered equipment (compatible with DC coil)

Auxiliary circuits of solar inverters

Small load control in marine and rail transit systems

  1. اقتراحات الاختيار
  2. Load Matching:

AC-3 loads (motor starting/operation): الأعلى. 5.5كيلوواط (400V), rated current 16A

AC-1 loads (الأحمال المقاومة): الأعلى. 20أ, 690V

  1. Control Voltage Confirmation: Ensure the coil voltage matches the system DC power supply (220-240V DC).
  2. Auxiliary Contact Requirements: Standard configuration is 1NC; for more contacts, select the VBC7-30-10 series (1لا) or expansion modules.
  3. Installation Environment:

مطلوب تخفيض درجة الحرارة عندما تتجاوز درجة الحرارة 40 درجة مئوية (rated current decreases by 10% for every 10℃ rise)

Additional protective measures are needed in dusty and humid environments

  1. Accessory Selection:

It is recommended to match with a surge suppressor (built-in for DC coils)

Optional auxiliary contact modules and thermal overload relays (على سبيل المثال, TA25DU series)

  1. نماذج بديلة:

Non-reversing version: BC7-30-01-05 (without mechanical interlock)

Different coil voltages: VBC7-30-01-01 (24V DC), VBC7-30-01-07 (12V DC)

  1. استكشاف الأخطاء وإصلاحها
ظاهرة الخللالأسباب المحتملةطرق استكشاف الأخطاء وإصلاحها
فشل المقاول في السحب1. No voltage or low voltage at the coil1. Check the control circuit voltage (220-240V DC)
2. Coil burnout2. Measure the coil resistance (تقريبا. 10k惟 under normal conditions)
3. Mechanical jamming3. Inspect contacts and mechanical mechanism, and remove foreign objects
Contactor releases immediately after pulling in1. Excessive voltage fluctuation1. Stabilize the control voltage and check the power supply capacity
2. Poor coil contact2. Tighten the coil terminals
3. Overload protection activation3. Check the status of the thermal overload relay
Contact heating/welding1. Load current exceeds the rated value1. Replace with a contactor of larger capacity or use it with derating
2. Contact oxidation or contamination2. Clean or replace the contacts
3. Frequent overload operation3. Inspect the load and eliminate overload causes
Interlock failure1. Damage to the mechanical interlock mechanism1. Inspect the interlock mechanism and replace if necessary
2. Improper installation leading to interlock release2. Reinstall to ensure proper engagement of the interlock mechanism
Severe coil heating1. Excessively high voltage1. Adjust the control voltage to the rated range
2. Coil short circuit2. Measure the coil resistance and replace the damaged coil
3. High ambient temperature3. Improve heat dissipation conditions and reduce the ambient temperature

سابعا. Installation and Wiring Key Points

  1. قبل التثبيت, confirm that the coil voltage is 220-240V DC, matching the control power supply.
  2. For reversing control, ensure that the mechanical interlock of the two contactors (forward/reverse) is correctly installed to prevent phase-to-phase short circuit.
  3. توصيلات الدائرة الرئيسية: Connect L1, L2, L3 to the power supply, and T1, T2, T3 to the motor; pay attention to the phase sequence (when switching between forward and reverse rotation).
  4. Control circuit wiring: Connect coil terminals A1 and A2 to the 220-240V DC power supply; pay attention to polarity (some models have no polarity requirements).
  5. Auxiliary contact wiring: The 1NC contact can be used for interlock control or status indication; pay attention to the rated current of the contact (usually 5A).
  6. Installation spacing: Keep a distance of at least 5mm from other components to ensure good heat dissipation.
  7. Pre-power-on inspection:

Check if the mechanical interlock operates flexibly and reliably

Check if the contacts are in good contact

Check if the coil wiring is correct

ABB VBC7-30-01 Core Parameter and Price Comparison Table with Same Series and Competitor Models

  1. Comparison of ABB Same Series Models (المعلمات الأساسية)
Parameter ItemVBC7-30-01-05VBC7-30-10-05BC7-30-01-05وصف الفرق
(220-240V DC)(220-240V DC)(220-240V DC)
يكتبMiniature reversing contactorMiniature reversing contactorMiniature non-reversing contactorVBC7 with mechanical interlock; BC7 without interlock
جهات الاتصال الرئيسية3لا (3-pole normally open)3لا (3-pole normally open)3لا (3-pole normally open)Identical
جهات الاتصال المساعدة1نورث كارولاينا (1 مغلقة عادة)1لا (1 مفتوحة عادة)1نورث كارولاينا (1 مغلقة عادة)Different auxiliary contact types
التصنيف الحالي16أ (ايه سي-3) / 20أ (ايه سي-1)16أ (ايه سي-3) / 20أ (ايه سي-1)16أ (ايه سي-3) / 20أ (ايه سي-1)Identical, suitable for 5.5kW (400V) محرك
الجهد المقنن690الخامس و690الخامس و690الخامس وIdentical
الجهد لفائف220-240V DC220-240V DC220-240V DCIdentical, DC operation with no noise
التعشيق الميكانيكيBuilt-in reliable mechanical interlockBuilt-in reliable mechanical interlockNoneExclusive to VBC7 series, preventing simultaneous closing of forward and reverse contactors
الحماية من الطفرةBuilt-in suppression diodeBuilt-in suppression diodeBuilt-in suppression diodeIdentical
طريقة التركيبDIN rail / screw mountingDIN rail / screw mountingDIN rail / screw mountingIdentical
عمر الخدمة الميكانيكية10 مليون عملية10 مليون عملية10 مليون عمليةIdentical
عمر الخدمة الكهربائيةايه سي-3: 100,000 العملياتايه سي-3: 100,000 العملياتايه سي-3: 100,000 العملياتIdentical
ايه سي-1: 1 مليون عمليةايه سي-1: 1 مليون عمليةايه سي-1: 1 مليون عملية
Protection RatingIP20IP20IP20Identical, must be installed inside control cabinet
Reference Priceتقريبا. 380-450تقريبا. 380-450تقريبا. 320-380BC7 is slightly cheaper; VBC7-30-01 and 30-10 are similarly priced
  1. Comparison of ABB VBC7-30-01 with Competitor Models (المعلمات الأساسية + سعر)
Parameter ItemABB VBC7-30-01-05Schneider LC1D18FDSiemens 3RT2016-1BB41+3RT2016-1BB41اقتراح الاختيار
(220-240V DC)(Reversing, 220V DC)(Reversing Combination, 220V DC)
Brand SeriesABB VBC7 SeriesSchneider LC1D SeriesSiemens 3RT2 Series
يكتبIntegrated reversing contactorIntegrated reversing contactorDual-contactor combinationABB/Schneider integrated design saves more space
(مع التعشيق الميكانيكي)(مع التعشيق الميكانيكي)(external mechanical interlock required)
جهات الاتصال الرئيسية3لا (3-pole normally open)3لا (3-pole normally open)3NO+3NO (dual contactors)Identical
جهات الاتصال المساعدة1نورث كارولاينا1NO+1NC1NO+1NC (per contactor)Schneider/Siemens have more abundant auxiliary contacts
التصنيف الحالي16أ (ايه سي-3) / 20أ (ايه سي-1)18أ (ايه سي-3) / 25أ (ايه سي-1)9أ (ايه سي-3) / 12أ (ايه سي-1)Schneider has higher rated current, suitable for 7.5kW motor
Applicable Motor Power5.5كيلوواط (400V AC-3)7.5كيلوواط (400V AC-3)4كيلوواط (400V AC-3)Schneider supports higher power
الجهد لفائف220-240V DC220V DC220V DCIdentical, DC operation with no noise
التعشيق الميكانيكيBuilt-in, reliable and durableBuilt-in, long mechanical service lifeExternal required, increased costABB/Schneider are more convenient to use
الحماية من الطفرةBuilt-in suppression diodeBuilt-in varistorBuilt-in varistorIdentical protection function
طريقة التركيبDIN rail / screw mountingDIN rail / screw mountingDIN rail / screw mountingIdentical
عمر الخدمة الميكانيكية10 مليون عملية10 مليون عملية10 مليون عمليةIdentical
عمر الخدمة الكهربائيةايه سي-3: 100,000 العملياتايه سي-3: 100,000 العملياتايه سي-3: 100,000 العملياتIdentical
ايه سي-1: 1 مليون عمليةايه سي-1: 1 مليون عمليةايه سي-1: 1 مليون عملية
Protection RatingIP20IP20IP20Identical, must be installed inside control cabinet
Width Dimension45مم55مم45mm*2 (dual contactors)ABB has the smallest volume
Reference Priceتقريبا. 380-450تقريبا. 420-480تقريبا. 450-520 (dual contactors)ABB offers the best cost performance
AdvantagesIntegrated design, quiet operation, smallest volumeHigh rated current, abundant auxiliary contactsSiemens ecosystem compatibility, strong diagnostic functionsSelect according to load power and space constraints

ثالثا. Price and Selection Replacement Summary

  1. Same Series Replacement Recommendations
Original ModelReplacement ModelReplacement Reasonملحوظات
VBC7-30-01-05VBC7-30-10-05Different auxiliary contact type (1NC→1NO)Confirm auxiliary contact requirements in the control circuit
VBC7-30-01-05BC7-30-01-05Lower price for non-reversing applicationsNot suitable for forward/reverse control, no mechanical interlock
VBC7-30-01-05VBC7-30-01-01Different coil voltage (220V DC→24V DC)Must match the system control power supply voltage
  1. Cross-Brand Replacement Recommendations
Original ModelOptimal ReplacementAlternative ReplacementReplacement Advantages
VBC7-30-01-05Schneider LC1D18FDSiemens 3RT2016 CombinationHigher rated current and applicable power
VBC7-30-01-05ABB VBC7-30-10-05Schneider LC1D12FDBetter compatibility with the same brand, no need to adjust installation dimensions
  1. نقاط الاختيار الرئيسية
  2. Load Matching: Select the corresponding rated current for standard loads; for heavy-duty applications, it is recommended to choose one size larger (على سبيل المثال, VBC7→Schneider LC1D25FD).
  3. Control Voltage: Ensure the coil voltage matches the system DC power supply (220-240V DC).
  4. جهات الاتصال المساعدة: Select 1NC/1NO or versions with more contacts according to the control circuit requirements.