Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter

Carlo Gavazzi WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6A current) وعالية ...

  • تفاصيل المنتج

كارلو جافازي WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6A current) and high protection degree (IP65 front panel). It is ideally applied in industrial automation, المباني التجارية, data centers and OEM equipment. It can monitor power parameters in real time, help users optimize energy consumption and reduce operating costs.

  1. Model Code Definition
Sectionشفرةوصف
كود السلسلةWM12-96Carlo Gavazzi WM12 series 96×96mm panel-mounted multi-functional power meter
Range CodeAV5380/660V line-line, 5(6)A AC current input, suitable for 400V power system
System Type3نظام ثلاث مراحل بأربعة أسلاك (configurable as three-phase three-wire, ARON, two-phase or single-phase)
نوع مصدر الطاقة3230V AC ±15% +10%, 50-60هرتز (Code A=24VAC, B=48VAC, C=115VAC, D=18-60VDC)
Function OptionXWithout RS485 output (S=With RS485 MODBUS/JBUS output)

رقم الطلب: WM12-96AV533X (Standard single package)

  1. Main Technical Specifications
فئةغرضقيمةRemark
Basic Infoنوع المنتجThree-phase multi-functional power meterBuilt-in programming keypad, TRMS true RMS measurement
عرض14mm LED, 3×3 digitsRefresh rate: 700آنسة, 12 measuring pages
نوع التركيبPanel mountingDimension:96×96×63mm, Cut-out size:61.4×61.4mm
فئة الحمايةFront IP65, Terminal IP20Comply with NEMA4x/12 standard
Electrical Specsنطاق الجهد380/660V L-L, 185-460V L-NAV5 range, دقة: ±0.5% FS +1 digit
النطاق الحالي5(6)وتكييف, Phase current:0.03-6أ, Neutral current:0.09-6أدقة: ±(0.5% خ.س +1 digit) within 0.25-6A
جهد الإمداد230V AC ±15% +10%, 50-60هرتزاستهلاك الطاقة:4.5فرجينيا
المعلمات المقاسةالجهد االكهربى, حاضِر, قوة, عامل الطاقة, تكرار, Demand, Maximum valueSystem-wide & phase-separated measurement supported
دقةActive/Apparent Power±(1% خ.س +1 digit) (0.25-6أ)±(1% خ.س +5 digits) at 0.03-0.25A
قوة رد الفعل±(2% خ.س +1 digit) (0.25-6أ)±(2% خ.س +5 digits) at 0.03-0.25A
تكرار±0.1% Hz (48-62هرتز)Sampling:1400 samples/s@50Hz, 1700 samples/s@60Hz
Neutral Current±(1.5% خ.س +1 digit) (0.25-6أ)±7 digits at 0.09-0.25A
تواصلواجهةلا أحد (X version)S version: RS485, MODBUS/JBUS, 9600 baud rate
مسافة الاتصالاتMax 1200m for S version, 2/4-wire connection
Ambient Specsدرجة حرارة التشغيل-5℃ ~ +50℃RH<90% non-condensing @40℃
درجة حرارة التخزين-30درجه مئوية ~ +60 درجه مئويةRH<90% non-condensing @40℃
فئة العزلOvervoltage Category III (اللجنة الانتخابية المستقلة 60664)Withstand 4000VAC between input and power supply for 1 دقيقة
Physical Specsمواد الإسكانSelf-extinguishing ABS (أول 94 V-0)وزن: approx.400g (with package)
المحطاتScrew typeMax cable cross-section:2.5مم², 5(6)A current input
شهادةمنعمComply with EN50084-1 Class A, EN61000-6-2 Class A
أولنعمcULus certified, meet North American safety standards
EMC StandardComply with EN61000-4-51.2/50μs surge immunity
  1. Full Model List of WM12-96 Series
Range CodeSystem Typeمزود الطاقةوظيفةنموذجرقم الطلب.
AV53(3-phase 4-wire)أ(24بطالة)X(No RS485)WM12-96.AV5.3.A.XWM12-96AV53AX
س(RS485)WM12-96.AV5.3.A.SWM12-96AV53AS
ب(48بطالة)XWM12-96.AV5.3.B.XWM12-96AV53BX
سWM12-96.AV5.3.B.SWM12-96AV53BS
ج(115بطالة)XWM12-96.AV5.3.C.XWM12-96AV53CX
سWM12-96.AV5.3.C.SWM12-96AV53CS
3(230بطالة)XWM12-96.AV5.3.3.XWM12-96AV533X
سWM12-96.AV5.3.3.SWM12-96AV533S
د(18-60VDC)XWM12-96.AV5.3.D.XWM12-96AV53DX
سWM12-96.AV5.3.D.SWM12-96AV53DS
AV63(3-phase 4-wire)3(230بطالة)XWM12-96.AV6.3.3.XWM12-96AV633X
سWM12-96.AV6.3.3.SWM12-96AV633S

نماذج خاصة: WM12-DIN (DIN rail type), WM14-96 (with 15th harmonic analysis)

  1. استبدال & النماذج المكافئة

4.1 Internal Carlo Gavazzi Replacement

Old ModelNew ModelReplacement Description
WM1-96WM12-96Upgraded true RMS measurement, دقة أعلى, added demand & max value display
WM12-96.AV5.3.D.SWM12-96.AV5.3.D.Sمتوافقة تماما, optimized firmware, support latest MODBUS protocol

4.2 Cross-brand Equivalent

ماركةEquivalent Modelالمزايا
شنايدرPM2000More cost-effective, higher front IP65 protection
سيمنز7KM2112Support more system types including ARON & two-phase, flexible programming
ايه بي بيE20012 display pages for clearer reading, standard 96×96mm mounting size
  1. مجالات التطبيق & Cases

5.1 Recommended Applications

طلبTypical Working Conditionالمزايا
الأتمتة الصناعيةMotor control center, distribution cabinet, PLC systemTRMS measurement, perfect for non-linear loads with high precision
المباني التجاريةCentral air conditioning, lighting system, elevator control3-phase 4-wire measurement, monitor unbalanced load, IP65 suit for machine room
الطاقة المتجددةPV inverter, wind power systemDemand & peak value monitoring, support single/three-phase systems
مركز البياناتنظام UPS, server cabinet power distributionدقة عالية, low power consumption 4.5VA, stable 24h operation
معدات تصنيع المعدات الأصليةIndustrial machinery, المعدات الطبية, testing instrumentStandard 96×96mm easy integration, optional RS485 communication

5.2 Not Recommended Applications

High voltage system (over 660V L-L, voltage transformer required)

High current system (over 6A, current transformer required)

Explosion hazardous area (non-explosion-proof design)

Underwater or long-term humid environment (only IP20 for terminals)

5.3 Application Cases

Case 1: Motor Control Center Renovation for Automobile Factory

Original equipment: Analog pointer meters with inaccurate reading and no data recording

حل: WM12-96.AV5.3.3.S with RS485 + SCADA system

Effect: Real-time monitor three-phase current, voltage and power, detect unbalanced load, save 15% طاقة, annual electricity saving about 80,000 يوان

Case 2: Energy Management System for Commercial Complex

Demand: Monitor power parameters of distribution cabinets on 12 floors, remote meter reading

حل: 12 sets WM12-96.AV5.3.3.S connected to central controller via MODBUS bus

Effect: Auto generate energy consumption report, identify high-energy areas, optimize power distribution, save 20% energy yearly

  1. Air Shipment Compliance & شهادة

6.1 Shipping Confirmation

غرضStatusتوضيح
Built-in Lithium BatteryلاExternal power supply only
Dangerous Goods ClassificationNon-dangerous goodsComply with IATA DGR rules, no special shipping limit
Transport Restrictionلا أحدShipped as general electronic goods
التعبئة والتغليفStandard anti-static packagePrevent static damage during transit

6.2 Certification Documents

CE Certificate: Available on official Carlo Gavazzi website (Doc ID:WM12 96 DS ENG 100317)

UL Certificate: Apply via global Carlo Gavazzi support center

Manufacturer Declaration: Include EMC, safety and RoHS compliance statement

  1. إرشادات الاختيار
  2. Range Selection: AV5 for 400V system (380/660V L-L), AV6 for 100V system (120/208V L-L)
  3. مطابقة الطاقة: Select A/B/C/3/D code according to on-site power supply to avoid damage
  4. تواصل: Choose S version for remote monitoring, X version for local display only
  5. تصاعد: Panel cut-out size 61.4×61.4mm; current signal must connect via CT, direct connection forbidden
  6. System Setting: Reset via keypad to three-phase three-wire, ARON, two-phase or single-phase as required
  7. Matching Accessories
ملحقنموذجوظيفة
المحول الحاليCT-500/5500A/5A for large current measurement
Voltage TransformerVT-400/100400V/100V for high voltage measurement
وحدة الاتصالاتRS485-USBConnect meter to PC for parameter setting & data reading
Mounting KitWM12-MOUNTFixing screws and gaskets for panel installation
Configuration SoftwareGavazzi Config ToolRemote parameter setting and file generation

Full Model List of Carlo Gavazzi Multi-functional Power Meters

  1. General Coding Rule
Sectionشفرةمعنى
مسلسلWM12-9696×96mm panel type
WM12-DINDIN rail type (4 وحدات)
يتراوحAV5380/660V L-L, 400نظام الخامس
AV6120/208V L-L, 100نظام الخامس
نظام1مرحلة واحدة
2Three-phase three-wire
3Three-phase four-wire
قوةA=24VAC, B=48VAC, C=115VAC, 3=230VAC, D=18-60VDC
وظيفةX=No RS485, S=With RS485 MODBUS
  1. Complete WM12-96 & WM12-DIN Model List

WM12-96 Panel Mount

AV5 Series (400V System)

All single-phase / three-phase three-wire / three-phase four-wire models with all power supply & communication options are fully listed as above.

AV6 Series (100V System)

Full range models are available in single-phase, three-phase three-wire and three-phase four-wire types.

WM12-DIN Rail Mount

Mainly three-phase four-wire AV5 & AV6 versions with all power supply and communication options.

  1. Extended High-end Models
نموذجميزةرقم الطلب.
WM14-96.AV5.3.3.S15th harmonic analysisWM14-96AV533S
WM30-96.AV5.3.3.S0.2 دقة عالية, 32nd harmonic FFT analysisWM30-96AV533S