CHINT Push Button NP2-11BN is a product of the NP2 series, suitable for industrial control circuits. وفيما يلي مقدمة مفصلة لها:
ميزات المنتج
التصميم الهيكلي: Adopts a metal head design with an IP40 protection rating, offering good dustproof performance. The screw fixing method is more secure than nut fixing, making it suitable for applications with vibration.
Contact Characteristics: Equipped with 1 Normally Open + 1 Normally Closed (1NO+1NC) اتصالات, with an initial contact resistance ≤ 50mΩ. The copper alloy contacts feature excellent electrical conductivity, high temperature resistance and oxidation resistance, ensuring stable electrical connections.
Working Principle: Normally self-resetting. That is, the button automatically springs back to its original position when released after being pressed, which can prevent the system from staying in an abnormal state for a long time due to misoperation.
تصميم المظهر: Adopts a standard circular structure as a whole. The shell is made of engineering plastic, with a solid hand feel and easy installation, and is compatible with various standard panel hole diameters.
المعلمات التقنية
الجهد المقنن: Suitable for AC circuits with a frequency of 50Hz or 60Hz and a rated working voltage up to 380V, as well as DC circuits with a working voltage up to 220V.
Conventional Free Air Thermal Current: Ith = 10A.
الحياة الميكانيكية: 1,000,000 operations for flat-head, mushroom-head and illuminated types.
الحياة الكهربائية: 500,000 AC operations and 200,000 DC operations for flat-head and mushroom-head types.
أبعاد التثبيت: Mounting plate hole diameter is Φ22.3⁺⁰·⁴mm.
Price Information: The market price varies according to purchase channels and quantities, with a reference price ranging from about 10 yuan to 20 يوان.
Installation Precautions for CHINT Push Button NP2-11BN
CHINT NP2-11BN is a 1NO+1NC self-resetting push button, suitable for industrial control circuits. Installation must comply with specifications to ensure stable equipment operation and personnel safety. The specific precautions are as follows:
- التحضير قبل التثبيت
- Model and Appearance Inspection
Confirm that the product model is NP2-11BN, consistent with the design and selection, to avoid contact function mismatch caused by model confusion.
Check that the button shell and contact terminals are intact without cracks, deformation, oxidation, rust or other defects; the self-resetting spring rebounds smoothly without jamming.
- Tool and Auxiliary Material Preparation
Essential tools: Φ22.3mm special hole opener, electric hand drill, Phillips screwdriver, متجرد الأسلاك, crimping tool;
Auxiliary materials: Cold-pressed terminals suitable for terminal wire diameters (optional), الشريط العازل, nameplates.
- Power-off Confirmation
قبل التثبيت, cut off all power of the circuit where the button is located, and hang a “No Switching On” sign to prevent electric shock.
- Panel Hole Drilling Requirements
- Hole Diameter and Thickness Specifications
The hole diameter is Φ22.3⁺⁰·⁴mm. An oversized hole will cause the button to loosen and reduce the protection rating; an undersized hole will squeeze the shell and cause deformation, affecting the reset function.
Suitable for panel thickness of 1~5mm. If the panel thickness exceeds 5mm, additional counterbore processing is required, otherwise the fixing nut cannot be tightened.
- Hole Position Requirements
The button installation position should avoid equipment vibration sources (such as motors and pumps) to prevent loose wiring or button failure caused by long-term vibration;
حجز مساحة كافية (≥30mm) on the back of the panel to facilitate wiring and terminal heat dissipation, and avoid interference with other components.
ثالثا. Wiring Operation Specifications
- Contact Function Distinction
The terminals of NP2-11BN are clearly marked. It is necessary to strictly distinguish between Normally Open (لا) and Normally Closed (نورث كارولاينا) contacts to avoid control logic errors caused by incorrect wiring:
Normally Open (لا) اتصال: Closes when the button is pressed and opens when released.
Normally Closed (نورث كارولاينا) اتصال: Opens when the button is pressed and closes when released.
- Wire and Terminal Requirements
Suitable for wire cross-sectional area of 0.5~2.5mm². An oversized wire cannot be inserted into the terminal, while an undersized wire is prone to heating and ablation;
Control the wire stripping length to 5~8mm, and avoid damaging the wire core during stripping; it is recommended to use cold-pressed terminals for crimping before inserting into the wiring terminals to enhance conductivity and vibration resistance.
- Wiring Tightening Requirements
Tighten the terminal screws with a Phillips screwdriver, with a torque controlled at 0.8~1.2N·m. Loose screws will lead to poor contact and heating, while over-tightening will damage the terminal threads;
بعد الأسلاك, gently pull the wires to confirm that there is no looseness; bundle the excess wires to avoid contact with other live parts.
- Fixing and Commissioning
- Installation and Fixing Steps
Insert the button body into the hole from the front of the panel to ensure that the button is perpendicular to the panel without skew;
Screw the fixing nut into place from the back of the panel, tighten it by hand and then use a wrench to turn it half a circle. Over-tightening is strictly prohibited to prevent cracking of the plastic shell.
- Power-on Commissioning Inspection
Before commissioning, reconfirm that the wiring is correct and remove tools and debris from the back of the panel;
After switching on the power, press the button to test the contact on-off status: observe whether the associated equipment (such as contactors and indicator lights) operates in accordance with the control logic, and check whether the button can quickly self-reset without jamming or delay when released.
- Environmental and Maintenance Precautions
- Environmental Adaptation Requirements
The button has an IP40 protection rating and is only suitable for indoor environments that are dry, dust-free and free of corrosive gases; if installed in a dusty environment, a matching dust cover must be added.
Avoid installation in high-temperature (>55℃) or low-temperature (<-25℃) environments to prevent aging or embrittlement of plastic components.
- Daily Maintenance Points
Regularly check whether the fixing nuts and wiring terminals are loose, especially in vibration environments where inspection should be carried out monthly;
When cleaning the button surface, cut off the power supply and wipe it with a dry soft cloth. Flushing with water or organic solvents is strictly prohibited.
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

















NH42-63-318x560.png)