ELESTA (Swiss safety relay brand under فطر) SIR4 Power high-current PCB-mount تتابع السلامة
- SIR: SIR4 series safety relay with forcibly guided contacts
- 222: تكوين الاتصال: 2 مفتوح عادة (لا) + 2 مغلق عادة (نورث كارولاينا) (dual-pole double-throw safety structure)
- ص: High-current version rated for 12A load (standard SIR222 is 10A)
Standard stock coil specifications:
SIR222P 24VDC (السائدة, part number H301164, coil resistance 760Ω)
SIR222P 12VDC (part number H301192)
Custom coil voltages available: 5/6/18/48/110VDC
Core Safety Certifications
متوافق مع IEC 61810-3 Type A Forcibly Guided Contacts and EN50205 machinery safety standards. Applicable to machine tool and automated safety circuits to meet safety contact fault monitoring requirements.
- الأبعاد الميكانيكية & تصاعد
Overall size: 46.4(ل) × 16(دبليو) × 30.7(ح) مم
تصاعد: Through-hole PCB soldering (14-pin footprint)
وزن: تقريبا. 32ز
Housing: Transparent green dustproof flame-retardant PC, allows visual inspection of coil and contact status
Standard through-hole pin pitch for PCB mounting; compatible with dedicated PCB sockets
- Coil Electrical Parameters (العاصمة)
| غرض | قيمة المعلمة |
| Nominal pull-in coil power | 0.75دبليو |
| Holding power consumption | 0.23دبليو (low-power latching, low heat generation) |
| 24VDC coil resistance | 760Ω ±10% |
| Pull-in voltage range | 70%~110% من الجهد المقنن (DC 16.8~26.4V) |
| Drop-out voltage | ≤10% Un |
| Dielectric withstand voltage (coil to contacts) | 2500V AC for 1 دقيقة |
| Coil protection | المدمج في الصمام الثنائي الطليق (prevents reverse breakdown of DC coils) |
- Core Contact Electrical Ratings (2NO+2NC Safety Forced Linkage)
4.1 Load Capacity (High-Current Advantage of SIR222P)
Continuous rated current: 12أ / 250بطالة (AC1 resistive load)
Peak inrush current: الأعلى. 60أ (20آنسة, suitable for inductive startup of motors and contactors)
Switching voltage range: AC 5~480V / DC 5~250V
Rated switching capacity: 3000فرجينيا
Minimum reliable switching load: 5أماه / 5V (no sticking for weak signal circuits)
Contact material: AgSnO2 silver tin oxide, مقاومة للقوس ومضادة للحام
4.2 Core Feature of Forcibly Guided Safety Design (Distinction from Standard Relays)
Forced mechanical linkage: NO and NC contacts within the same channel can never conduct simultaneously
Monitoring logic: Safety circuits can detect NC feedback signals to judge contact welding faults
Dielectric withstand voltage between contacts: 4000بطالة; open contact withstand voltage: 1500بطالة
Contact creepage distance: ≥10mm between coil and output contacts; ≥8mm between two output contact banks for enhanced isolation protection
4.3 Service Life Ratings
الحياة الميكانيكية: 10 million operations under no-load conditions
الحياة الكهربائية (12A/250VAC resistive): 250,000 العمليات
Factory contact resistance: ≤100mΩ (tested at 6V/100mA)
- 14-Pin Pinout Definition (Standard Top Silkscreen Layout)
Coil Pins (Drive Side)
13(+), 14(-): DC coil positive and negative terminals with built-in diode. Connect 14 to 0V and 13 to DC24V.
Two Independent Safety Contact Banks (1NO+1NC per bank with forced linkage)
قناة 1 (First Contact Bank)
1: Common COM1 | 2: NC Normally Closed | 3: NO Normally Open
قناة 2 (Second Contact Bank)
4: Common COM2 | 5: NC Normally Closed | 6: NO Normally Open
Pins 7~12 are unoccupied locating pins with no electrical connections.
- Environmental Operating Parameters
درجة حرارة التشغيل: -40درجه مئوية ~ +70 درجه مئوية
Storage temperature: -40درجه مئوية ~ +85 درجه مئوية
رطوبة: 5%~95% RH non-condensing
اهتزاز / مقاومة الصدمات: IEC60068 industrial equipment grade, suitable for machine tool and production line control cabinets
- سيناريوهات التطبيق النموذجية (Dedicated for Safety Circuits)
- Dual-channel monitoring for machine safety door and emergency stop circuits (NC contacts detect welding faults)
- Safe cut-off circuits for inverter and servo enable signals
- Output expansion for safety light curtains and safety mats on automated production lines
- Safety control circuits for rail transit, medical equipment and lifts
- High-current output expansion for PLCs (direct drive of contactors and solenoid valves up to 12A)
- Equipment fault diagnosis feedback (self-inspection of contact adhesion via NC contacts)
- Cross-Series Model Selection Comparison Table
| نموذج | تكوين الاتصال | Continuous Current | قوة الملف | سيناريو التطبيق |
| SIR222P | 2لا + 2NC | 12أ | 0.75دبليو | High-current safety circuits, contactor driving (primary recommended model) |
| SIR222 | 2لا + 2NC | 10أ | 0.6دبليو | Medium/low-current signal safety circuits |
| SIR312P | 3لا + 1NC | 12أ | 0.75دبليو | Multi-output single-channel monitoring |
| SIM222 | 2لا + 2NC | 8أ | 1دبليو | Compact low-load safety relay |
- Troubleshooting Matrix
| ظاهرة الخلل | السبب الجذري | حل |
| Coil energized but NO contacts fail to close | 1. Reversed coil polarity; 2. Supply voltage below 70% الجهد المقنن; 3. لفائف محترقة | Swap pins 13 و 14; Measure DC supply voltage; استبدال التتابع |
| NO contacts stick closed after power-off, NC contacts cannot close (critical safety failure) | Load current exceeds 12A; repeated heavy arcing welds contacts | Reduce load or add intermediate relay; Install brand-new SIR222P |
| Both NC and NO contacts conduct during safety inspection | Damaged forcibly guided mechanical structure; relay cannot be repaired | Replace immediately; prohibit further use in safety circuits |
| Severe contact voltage drop and overheating | Poor PCB soldering; long-term near full 12A load | Re-solder PCB pins; Parallel additional contacts for current sharing |
| Coil shows no pull-in action at all | Open circuit at pins 13/14; No power supply output | Inspect power circuit and PCB solder joints for open connections |
- Mandatory Installation & Usage Prohibitions
- NC contact safety monitoring must not be omitted: Safety devices must read NC feedback signals; otherwise anti-welding protection is lost.
- Long-term resistive load shall not exceed 12A; inductive loads are recommended to be derated to 8A.
- DC coils must not be energized with reversed polarity for extended periods (built-in diode only provides one-time transient protection; sustained reverse voltage burns the coil).
- Prohibit full-load continuous operation above 70℃ in sealed cabinets; sufficient heat dissipation space must be reserved.
- Do not parallel contacts of different relays for current expansion; single-channel load cannot exceed rated current of one contact.
- Only PCB soldering mounting is allowed; avoid violent bending or repeated plugging/unplugging of pins.
- Standard Packing List
1 × SIR222P relay unit
- Original manufacturer safety datasheet, TÜV/CE safety certification documents
- Standard package quantity: 15 قطع لكل صندوق
Application Manual for ELESTA SIR222P Forcibly Guided Safety Relay
Document Version: V1.0|Applicable Models: SIR222P-24VDC (السائدة), SIR222P-12VDC
ماركة: ELESTA (Switzerland)|Safety Standards: اللجنة الانتخابية المستقلة 61810-3 Type A Forcibly Guided Contacts, EN50205, ISO13849-compliant safety circuit design
Table of Contents
- نظرة عامة على المنتج & شرح كود النموذج
- Complete Electrical Specifications
- Pinout Definition & Standard Wiring Specifications
- 4 Standard Industrial Wiring Schemes (Including Safety Circuits)
- PCB Mounting, Soldering & Mechanical Installation Standards
- Load Selection & Derating Guidelines
- Core Rules for Safety Circuit Design (Requirements for Forcibly Guided Contacts)
- Power-On Commissioning & Functional Test Procedures
- Troubleshooting Matrix
- Mandatory Installation & Usage Prohibitions
- Cross-Series Alternative Model Comparison
- التعبئة والتغليف & وثائق الشهادة
- نظرة عامة على المنتج & شرح كود النموذج
1.1 Model Code SIR222P
SIR: SIR4 Power series PCB-mounted forcibly guided safety relay
222: Contact structure: 2لا + 2نورث كارولاينا, two independent banks of 1NO+1NC forced-linkage contacts
ص: High-current version with 12A AC1 continuous rating per contact (standard SIR222 is only 10A)
1.2 Core Safety Features (Distinction from Ordinary Relays)
- Forcibly Guided Mechanical Structure: NO and NC contacts within one channel can never conduct simultaneously. If contacts weld shut, the paired opposite contacts remain open to enable fault diagnosis.
- Coil-to-contact dielectric withstand voltage: 2500بطالة; inter-contact isolation: 4000بطالة. Creepage distances meet safety isolation criteria.
- AgSnO2 silver tin oxide contacts with thin gold plating, anti-arcing and anti-welding, compatible with both high-current loads and weak signal detection.
- Built-in coil freewheeling diode (dedicated for DC coils to prevent reverse voltage breakdown).
1.3 Applicable Safety Performance Levels
Suitable for PLd / القطة 3, SIL2 safety cut-off circuits. Dual-channel redundant design achieves Cat.4 / PLe.
- Complete Electrical Specifications
2.1 معلمات الملف (العاصمة)
| غرض | SIR222P-24VDC | SIR222P-12VDC |
| Nominal pull-in power | 0.75دبليو | 0.75دبليو |
| Holding power consumption | 0.23دبليو | 0.23دبليو |
| DC coil resistance | 760Ω±10% | 190Ω±10% |
| Pull-in voltage range | 70%~110% Un (16.8~26.4VDC) | 8.4~13.2VDC |
| Drop-out voltage | ≤10% Un | ≤10% Un |
| Coil reverse protection | المدمج في الصمام الثنائي الطليق (Pin13+, Pin14-) | المدمج في الصمام الثنائي الطليق |
| Coil dielectric withstand voltage | 2500V AC for 1min | 2500V AC for 1min |
2.2 Contact Load Ratings (Per 1NO/1NC Channel)
- AC1 resistive: 12أ / 250بطالة, max switching capacity 3000VA
- AC15 inductive (المقاولين / صمامات الملف اللولبي): 8أ / 250بطالة (derating mandatory)
- DC13 inductive: 5أ / 24VDC
- Peak surge current: 60أ (short-duration 20ms)
- Minimum reliable switching load: 5أماه / 5V (no poor contact for PLC weak feedback signals)
- Contact material: AgSnO2 with 0.2~0.4μm gold plating
- Factory contact resistance: ≤100mΩ (6V/100mA test condition)
2.3 Service Life Ratings
الحياة الميكانيكية (لا تحميل): 10 مليون عملية
الحياة الكهربائية (12A/250VAC resistive): 250,000 العمليات
الحياة الكهربائية (8A inductive load): 100,000 العمليات
2.4 البيئية & المعلمات الميكانيكية
Overall dimensions: 46.4(ل)×16(دبليو)×30.7(ح)مم, 14-pin through-hole PCB mount
وزن: 32ز
درجة حرارة التشغيل: -40درجه مئوية ~ +70 درجه مئوية (enhanced heat dissipation required for full load at 70℃)
Storage temperature: -40درجه مئوية ~ +85 درجه مئوية
رطوبة: 5%~95% RH non-condensing
مقاومة الاهتزاز: 10~55 هرتز, 1.5mm amplitude for 2 hours on each of three axes
Housing: Transparent green flame-retardant PC for visual contact inspection
- Pinout Definition (Top Silkscreen View, Standard PCB Footprint)
3.1 Coil Drive Pins
13: Coil positive DC+
14: Coil negative DC(cathode of built-in diode; sustained reverse connection prohibited)
3.2 Two Independent Forcibly Guided Contact Banks (COM+NC+NO per bank)
قناة 1 (First Safety Contact Bank)
1: Common COM1
2: NC1 Normally Closed (forced linkage feedback contact)
3: NO1 Normally Open (main power output)
قناة 2 (Second Safety Contact Bank)
4: Common COM2
5: NC2 Normally Closed (forced linkage feedback contact)
6: NO2 Normally Open (main power output)
3.3 Unoccupied Pins
دبابيس 7,8,9,10,11,12: Locating reinforcement only, no electrical connection, wiring forbidden.
3.4 Forced Linkage Logic (Core Safety Principle)
Coil de-energized (open state): Pins 2-NC1 and 5-NC2 conduct; Pins 3-NO1 and 6-NO2 open
Coil energized (pulled-in state): Pins 2-NC1 and 5-NC2 open; Pins 3-NO1 and 6-NO2 conduct
Fault judgment rule: If NC contacts remain closed after coil energization → NO contacts welded shut; safety circuit triggers fault and equipment shutdown.
- Four Standard Industrial Wiring Schemes
مخطط 1: Dual-Channel Safety Cut-Off Circuit (توقف الطوارئ / باب الأمان, الأكثر شيوعًا)
وصف الوظيفة
Two independent NO contacts cut servo/inverter enable signals; two NC contacts connect to PLC for contact welding fault monitoring, complying with ISO13849 Cat.3 safety requirements.
خطوات الأسلاك
- Coil drive: PLC 24V+ output → Pin13; 0V → Pin14
- Power output circuit (two independent cut-off paths, parallel connection prohibited)
قناة 1: 24VAC/DC supply → COM1(Pin1); NO1(Pin3) → Servo Enable Coil 1
قناة 2: 24VAC/DC supply → COM2(Pin4); NO2(Pin6) → Servo Enable Coil 2
- Fault feedback monitoring (NC contacts wired to PLC digital input)
NC1(Pin2) and NC2(Pin5) shorted together and connected to PLC PNP input; PLC logic: NC contacts must open when relay pulls in. Continuous conduction indicates contact welding and locks out equipment startup.
قاعدة السلامة الإلزامية
Two output loads must be independent. Parallel connection of NO1 and NO2 for current expansion destroys dual-channel redundant safety design.
مخطط 2: PLC High-Current Output Expansion (Solenoid Valve / Contactor Drive)
نطاق التطبيق
PLC single-point output current ≤0.5A, insufficient for direct drive of 10A solenoid valves; SIR222P expands contact current capacity.
- لفائف: PLC output drives Pins13/14 (24VDC)
- Main circuit AC220V live wire → COM1(Pin1), كوم2(Pin4)
- NO1(Pin3) and NO2(Pin6) parallel to solenoid coil (parallel allowed for resistive loads, not recommended for inductive loads)
- NC contacts unused or wired to alarm indicator light (light illuminates when relay de-energized)
مخطط 3: Equipment Self-Diagnosis Circuit (Safety Light Curtain Output Expansion)
- Dual-channel NC signals from safety light curtain wired in series to drive relay coil Pins13/14
- Two NO contacts cut main contactor power supply; two NC contacts feed real-time contact status to PLC
- منطق: Curtain blocked → coil de-energized → NO contacts open and machine stops; If NC contacts stay closed with unobstructed curtain, relay contact damage is detected and alarm interlock activates.
مخطط 4: Mixed Weak Signal & High-Current Circuit (Contact Channel Isolation)
- Channel1 NO contacts: Drive high-current AC220V contactors
- Channel2 NC contacts: Feed 5V weak feedback signal to MCU IO ports (gold-plated contacts guarantee stable low-current contact performance)
Prohibition: Do not share one contact bank for both high-current inductive loads and 5V weak signals; arcing contaminates contact surfaces and causes intermittent weak signal faults.
- PCB Mounting & Soldering Standards
5.1 PCB Pad Design Requirements
Pin hole diameter: 1.3مم, pad diameter ≥2.2mm
Standard pin pitch layout compatible with all 14-pin relays
Wider copper traces for COM/NO/NC high-current pins; copper thickness ≥35μm, trace width ≥5mm for 12A loads
5.2 Soldering Process Specifications
- Wave soldering peak temperature ≤260℃, contact duration ≤4s; hand iron temperature ≤350℃, single pin soldering time ≤3s
- Prolonged high-temperature heating of pins is forbidden, as it melts internal contact plastic supports
- Solder joints must be fully filled without cold solder or bridging between adjacent pins
- Clean flux residue after soldering to prevent leakage and creepage currents
5.3 متطلبات تبديد الحرارة
Continuous full 12A operation: Increase PCB copper trace heat dissipation area; cabinet ambient temperature ≤60℃
Ambient temperature of 70℃: Load must be derated to ≤8A
- Load Selection & Derating Standards
| نوع التحميل | Rated Permitted Current | Mandatory Derating Explanation |
| AC250V resistive (heating lamps, resistors) | 12أ | No derating required for long-term stable operation |
| AC250V inductive (المقاولين, صمامات الملف اللولبي) | 8أ | Inductive kickback arcs occur at power-off; mandatory 1/3 derating |
| DC24V inductive (electromagnetic clutches) | 5أ | Poor DC arc extinction performance; significant derating required |
| Weak signal 5~24V (PLC feedback) | ≤0.5A | Only use gold-plated NC contacts; do not share channel with high-current loads |
Recommended Arc Suppression Measures
Fit absorption components across inductive load coils:
AC loads: RC absorption circuit (0.1μF capacitor in series with 100Ω resistor)
DC loads: Freewheeling diode wired in reverse parallel across coil terminals
- Mandatory Core Rules for Safety Circuit Design (Violation Invalidates Safety Certifications)
- NC contact monitoring cannot be omitted
All safety cut-off circuits (توقف الطوارئ, safety doors, light curtains) must route both NC contact banks to the upper controller (بلك) for welding diagnosis. Circuits without monitoring fail to meet IEC61810-3 safety requirements.
- Dual-channel outputs must not be paralleled
Two NO contacts provide redundant safety cut-off; each must drive an independent load. Parallel connection eliminates fault isolation capability.
- Single-channel cut-off is prohibited for safety applications
Using only one NO contact to cut power while leaving the other unused downgrades safety classification directly to Cat.1 and fails machine safety acceptance tests.
- Do not series multiple safety relay contacts for current expansion
Multi-stage series connection increases contact failure probability and reduces safety level.
- Coil power supply must share the same source as the safety circuit. Separate power supplies cause asynchronous logic operation.
- Power-On Commissioning & Functional Test Procedures
8.1 Static Pre-Power Test (Multimeter Required)
- Coil de-energized state: Measure continuity between 1-2 و 4-5; open circuit between 1-3 و 4-6
- Measure coil resistance at Pins13/14 (760Ω for 24VDC model) to rule out short/open circuits
- Verify no continuity between unoccupied pins and coil/contact terminals
8.2 Energized Pull-In Test
- Apply rated DC24V to Pin13(+) and Pin14(-)
- Multimeter verification: Open circuit between 1-2 و 4-5; continuity between 1-3 و 4-6
- Cut coil supply voltage; contacts reset rapidly to original state
8.3 Safety Fault Simulation Test (Mandatory for Acceptance)
Manually simulate NO contact welding by shorting Pins1 and 3. With coil energized, NC1 (Pin2) remains conductive. PLC detects persistent NC closure and triggers fault alarm to validate the forcibly guided mechanical design.
- Troubleshooting Matrix
| ظاهرة الخلل | السبب الجذري | Standard Resolution |
| Coil energized, NO contacts fail to close | 1. Reversed Pin13/14 polarity; 2. Supply below 70% و; 3. Open coil winding | Swap coil terminals, measure supply voltage, replace relay |
| NO contacts stick closed after power-off, NC cannot close | Load exceeds 12A; no absorption circuit for inductive loads leading to arc welding | Install RC/diode absorption, derate load, replace relay |
| Coil pulls in but NC contacts remain closed (critical safety failure) | Damaged forcibly guided mechanical linkage, seized contacts | Discard and replace immediately; ban use in safety circuits |
| Contact overheating, voltage drop >1V | Poor PCB soldering, continuous 12A full load at high temperature, insufficient copper trace width | Re-solder joints, enlarge PCB heat dissipation traces, derate operating load |
| Intermittent PLC weak signal feedback | NC contacts previously carrying high-current loads with carbonized arc deposits on contact surfaces | استبدال التتابع; separate high-current and weak signal channels |
| No coil pull-in action, zero voltage detected | Open circuit at Pins13/14, blown power fuse | Inspect PCB solder pads and 24V supply circuit |
| Leakage short between adjacent pins | Residual flux condensation, cabinet internal condensation | Clean PCB surface, improve cabinet dehumidification and ventilation |
- Absolute Installation & Usage Prohibitions
- Omission of NC contact welding monitoring on safety cut-off circuits voids safety certification validity.
- Continuous resistive loads exceeding 12A or inductive loads exceeding 8A burn contact sets.
- Long-term reverse energization of DC coils destroys the built-in freewheeling diode.
- Do not run continuous full 12A loads above 70℃ in sealed cabinets.
- Do not share one contact bank for both high-current inductive loads and 5V weak signal circuits.
- Parallel connection of two NO contacts for current expansion is forbidden in safety circuit applications.
- Prolonged full-load operation at ambient temperature above 70℃ is prohibited.
- Violent pin bending, repeated plugging/unplugging, and extended high-temperature soldering are forbidden.
- Do not deploy in circuits above AC480V, exceeding contact voltage withstand ratings.
- Cross-Series Alternative Selection Comparison
| نموذج | تكوين الاتصال | Per-Contact Rated Current | قوة الملف | Application Difference |
| SIR222P | 2لا + 2NC | 12A AC1 | 0.75دبليو | High-current safety cut-off, direct contactor drive (primary model) |
| SIR222 | 2لا + 2NC | 10A AC1 | 0.6دبليو | Medium/low-current signal safety circuits, low power consumption demand |
| SIR312P | 3لا + 1NC | 12A AC1 | 0.75دبليو | Multi-channel power output with single fault monitoring path |
| SIM222 | 2لا + 2NC | 8A AC1 | 1دبليو | Compact low-load PCB control boards |
- التعبئة والتغليف & وثائق الشهادة
12.1 Standard Packing List
1 × SIR222P-24VDC safety relay
- Original manufacturer datasheet
- Copies of CE and TÜV safety certification
- Standard carton quantity: 15 قطع لكل صندوق
12.2 Compliance Certifications
CE Industrial Equipment Certification
TÜV IEC 61810-3 Type A Forcibly Guided Contact Certification
EN50205 Machinery Safety Standard Compliance
RoHS Lead-Free Environmental Compliance Certification