CHF100ASeries Name: Vector General-Purpose Frequency Converter (enhanced version of the CHF series, integrating the advantages of CHF100 and CHE100)
055زSuitable for standard motor power of 55kW (G = General Load)
075صSuitable for heavy-duty motor power of 75kW (P = Heavy Load)
4Suitable for three-phase 400V-class voltage (380-415الخامس و)

  • تفاصيل المنتج

إنفت-CHF100A-055ز-075P-4 INVT Vector General-Purpose Frequency Converter

  1. تفسير النموذج
الجزء النموذجيوصف
INVTBrand Logo of INVT
CHF100ASeries Name: Vector General-Purpose Frequency Converter (enhanced version of the CHF series, integrating the advantages of CHF100 and CHE100)
055زSuitable for standard motor power of 55kW (G = General Load)
075صSuitable for heavy-duty motor power of 75kW (P = Heavy Load)
4Suitable for three-phase 400V-class voltage (380-415الخامس و)
  1. المعلمات التقنية الأساسية
  2. المعلمات الكهربائية الأساسية
Parameter Itemقيمةملاحظات
Rated Input Voltage380-415الخامس و, three-phase, 50/60هرتزVoltage fluctuation range ±15%
Rated Output Power55كيلوواط (standard load) / 75كيلوواط (heavy load)Rated value for continuous operation
Rated Output Current105أ (معيار) / 135أ (heavy load)At ambient temperature of 40℃
Output Frequency Range0.00-600.00هرتزAccuracy ±0.01Hz
Control ModeSensorless Vector Control (SVC), V/F Control, Torque ControlThree modes optional
  1. Performance Indicators
Parameter ItemقيمةApplicable Conditions
Starting Torque0.5هرتز / 150% rated torqueIn sensorless vector control mode
Speed Regulation Accuracy0.2% rated speedIn SVC mode
Torque Response Time<20آنسةDuring dynamic load changes
Carrier Frequency1.0-15.0kHzAdjustable according to motor noise and heating
Overload Capacity150% rated current for 1 minute, 180% rated current for 10 ثوانيFor standard load; 120% rated current for 1 minute for heavy load
  1. المعلمات الميكانيكية والبيئية
Parameter ItemقيمةStandard/Remarks
فئة الحمايةIP20 (main unit)اللجنة الانتخابية المستقلة 60529, must be installed in control cabinet
Cooling MethodForced Air CoolingBuilt-in cooling fan, automatic derating when overheated
درجة حرارة التشغيل-10℃~+40℃For every 1℃ rise above 40℃, rated current decreases by 1%, maximum temperature 50℃
درجة حرارة التخزين-25℃~+65℃No condensation, no corrosive gas
طريقة التركيبWall-mounted / Cabinet-mountedReserved heat dissipation space required (≥100mm top and bottom, ≥50mm left and right)

ثالثا. الميزات الوظيفية

  1. Excellent Control Performance: Adopts DSP control system to realize sensorless vector control, effectively suppressing low-frequency oscillation.
  2. Comprehensive Protection Functions: Equipped with multiple protection functions such as overcurrent, overvoltage, undervoltage, overtemperature, phase loss, الزائد, ground fault and short circuit.
  3. Rich Application Functions: Built-in PLC simple programming, multi-speed control (up to 16 speeds), PID control, frequency swing control, synchronous control, إلخ.
  4. Strong Communication Capability: واجهة RS485 القياسية, دعم بروتوكول Modbus RTU, expandable with PROFIBUS-DP, DeviceNet and other fieldbuses.
  5. Flexible Input and Output: 15 digital I/O channels (9DI/6DO by default), 2 analog input channels (0-10V/4-20mA), 2 analog output channels.
  6. Significant Energy-saving Effect: Functions such as Automatic Voltage Regulation (AVR), automatic current limiting, sleep and wake-up, especially suitable for energy-saving transformation of fan and pump loads.
  7. Application Scope
  8. Fans and Pumps: Boiler induced draft fans, central air conditioning fans, cooling tower fans, oilfield water injection pumps, oil transfer pumps, chemical process pumps, إلخ.
  9. Industrial Machinery: Air compressors, injection molding machines, extruders, printing machines, packaging machines, textile machinery, CNC machine tool spindle control.
  10. Building Materials and Metallurgy: Cement rotary kilns, ball mills, belt conveyors, hoists, auxiliary systems of steel rolling equipment.
  11. Other Fields: Mining machinery, port cranes, pharmaceutical equipment, food processing machinery, sewage treatment equipment.
  12. اقتراحات الاختيار
  13. Load Type Matching: Select type G for standard loads (المشجعين, مضخات), and type P for heavy loads (الضواغط, extruders).
  14. Motor Power Adaptation: The rated power of the frequency converter should be ≥ the rated power of the motor; it is recommended to select one level higher for heavy-duty applications.
  15. Environmental Condition Consideration: Derating use or additional protective measures are required for high-temperature, high-altitude and dusty occasions.
  16. Special Function Requirements: Select models with corresponding interfaces for communication networking; select vector control mode for fast response.
  17. Accessory Selection: Optional input and output reactors, filters, braking units, operation panels (universal for CHV100 series).
  18. استكشاف الأخطاء وإصلاحها
Fault CodeFault CauseTroubleshooting Method
OVDC bus overvoltageCheck grid voltage, extend deceleration time, install braking unit.
UVDC bus undervoltageCheck grid voltage, shorten acceleration time, check input phase loss.
OCOutput overcurrentCheck insulation of motor and cables, تقليل الحمل, extend acceleration time.
OHFrequency converter overtemperatureCheck cooling fan, clean air duct, reduce ambient temperature.
PHInput phase lossCheck input power supply, tighten wiring terminals, replace damaged fuses.
GFGround faultCheck insulation of motor and cables, eliminate ground fault points.

سابعا. Installation and Wiring Key Points

  1. قبل التثبيت, confirm that the power supply voltage matches the rated voltage of the frequency converter, disconnect the power supply and verify no voltage.
  2. Adopt 35mm DIN rail mounting or wall-mounted mounting to ensure sufficient heat dissipation space.
  3. توصيلات الدائرة الرئيسية: R/L1, S/L2, T/L3 are inputs; ش, V, W are outputs; PE is the grounding terminal.
  4. Control circuit wiring: Shielded wires should be used for analog input, with the shielding layer grounded at one end; digital input should avoid routing in the same slot as high-voltage electricity.
  5. Check parameter settings before power-on, especially basic parameters such as motor rated power, rated current and rated frequency.