PR18S-BC10DNO is an M18 cylindrical plastic housing diffuse-reflective photoelectric sensor from LANBAO (شنغهاي لانباو الاستشعار) سلسلة PR18S. It adopts a dedicated control IC for stable performance and integrates multiple circuit protections. Rated IP67 for dust and water resistance, it is a general-purpose object detection component widely used in industrial automation. It comes standard with a 2-meter PVC cable (لاحقة: -E2).
- Model Code Decoding
The full standard model is PR18S-BC10DNO-E2. The definition of each code is as follows:
PR18S: سلسلة المنتجات, featuring M18×1 thread, PBT plastic housing and diffuse-reflective detection principle
BC10: Detection specification
BC: Diffuse-reflective (direct reflection) detection mode
10: Rated sensing distance of 10cm (fixed, غير قابل للتعديل)
د: Power supply type, DC 10~30VDC
ن: نوع الإخراج, NPN
يا: Output logic, مفتوح عادة (لا; output turns on when an object is detected)
-E2 (Default suffix): Cable outlet, standard 2m PVC cable; suffix -C stands for M12 4-pin connector type
- المواصفات الفنية الرئيسية
| فئة | مواصفة |
| Detection Mode | Diffuse reflection (direct reflection) |
| Light Source | 880nm Infrared LED |
| Rated Sensing Distance | 10cm (based on 90% reflectivity white card, غير قابل للتعديل) |
| جهد الإمداد | 10 ~ 30 VDC |
| نوع الإخراج | 3-wire NPN Normally Open (لا) |
| Max Load Current | ≤300mA |
| الاستهلاك الحالي | ≤25mA |
| وقت الاستجابة | <8.2ms |
| Repeat Accuracy | ≤5% Sr |
| Hysteresis Range | 3% ~ 20% Sr |
| وظائف الحماية | Reverse polarity protection, حماية ماس كهربائى, حماية الزائد, حماية الطفرة |
| Status Indicator | Yellow LED (lights up when object is detected) |
| مواد الإسكان | PBT Engineering Plastic |
| البعد الشامل | M18×1 thread × 53.5mm (body length) |
| فئة الحماية | IP67 (Compliant with IEC Standard) |
| درجة حرارة التشغيل | -15درجه مئوية ~ +55 درجه مئوية |
| Ambient Humidity | 35% ~ 95%RH (غير التكثيف) |
| الشهادات | م, أول |
- Full Model List of DC Diffuse-Reflective Sensors in the Same Series
| Sensing Distance | NPN NO | NPN NC | PNP NO | PNP NC | NPN NO+NC | PNP NO+NC |
| 10cm (Non-adjustable) | PR18S-BC10DNO | PR18S-BC10DNC | PR18S-BC10DPO | PR18S-BC10DPC | PR18S-BC10DNR | PR18S-BC10DPR |
| 40cm (قابل للتعديل) | PR18S-BC40DNO | PR18S-BC40DNC | PR18S-BC40DPO | PR18S-BC40DPC | PR18S-BC40DNR | PR18S-BC40DPR |
ملحوظة: All models are equipped with -E2 (2m cable) بشكل افتراضي; replace the suffix with -C for connector version.
- Wiring Definition (3-wire Cable Version)
Brown wire: Power positive (+10~30 فولت تيار مستمر)
Blue wire: Power negative (0V / أرض)
Black wire: Signal output (NPN NO; output conducts when object is detected, connect to the negative side of load)
- التطبيقات النموذجية
Workpiece presence detection and counting on automated production lines
Material detection for packaging and printing industries
Object recognition and sorting trigger on warehouse conveyor lines
Limit positioning and home position detection for equipment stations
Missing part and falling part detection for small components
- Troubleshooting Matrix for Common Faults
| ظاهرة الخلل | السبب الجذري | Step-by-Step Solutions |
| Indicator off and no output after power-on | 1. Reverse power polarity | 1. Check brown and blue wires and rewire correctly |
| 2. Supply voltage out of 10~30VDC range | 2. Measure supply voltage with multimeter to ensure it is within rated range | |
| 3. Internal cable breakage | 3. Replace cable or conduct cross test with spare sensor | |
| No signal output even when object is detected | 1. Object beyond effective sensing distance | 1. Reduce the distance between sensor and object with proper margin |
| 2. Low reflectivity of measured object (pure black / light-absorbing material) | 2. Use high-reflective surface or select 40cm long-distance model | |
| 3. Wrong wiring of output circuit | 3. Verify complete connection of black output wire and load circuit | |
| False triggering & continuous output with no object | 1. Highly reflective objects in background | 1. Adjust mounting angle to avoid reflective background |
| 2. Strong ambient light directly irradiating the receiver lens | 2. Install light shield to block strong direct light | |
| 3. Severe electromagnetic interference | 3. Route sensor cables away from power cables and ensure proper grounding | |
| Fluctuating and unstable output signal | 1. Object stays at the detection boundary | 1. Fine-tune mounting distance to stay away from critical zone |
| 2. Dust or dirt covering the lens | 2. Clean the lens with a soft dry cloth |
- نماذج بديلة
Upgraded model of the same brand: PR18-BC10DNO (Nickel-copper alloy metal housing with higher mechanical strength, المعلمات الكهربائية متطابقة)
Cross-brand equivalent alternatives: OMRON E3Z-D61, Schneider XUB5BNANL2
PR18S-BC10DNO is a standard M18 plastic housing diffuse-reflective photoelectric sensor manufactured by LANBAO. See physical specifications below:
- Detailed Mounting Dimensions
This sensor adopts threaded cylindrical mounting. Dimensions and mounting regulations are specified as follows:
| غرض | مواصفة |
| Main Thread | M18 × 1mm (Metric fine thread) |
| Effective Thread Length | 30مم |
| Sensor Body Length (Excluding cable/connector) | تقريبا. 53.5مم (cable version) |
| Sensing Face Diameter | Φ18mm |
| الملحقات القياسية | 2 pcs M18 lock nuts, 1 pc anti-loose washer |
| Recommended Mounting Hole | Φ18.5mm through hole |
| Minimum Spacing for Side-by-Side Installation | ≥40mm (to prevent optical crosstalk) |
Mounting Instructions
- Fix the sensor on cabinet panels, brackets and other mounting positions via two lock nuts; the extension length is adjustable.
- Align the sensing face towards the moving direction of measured objects. The tilt angle is recommended ≤15°, otherwise the effective sensing distance will be reduced.
- This is a non-flush mount sensor. Do not embed the sensing face into metal mounting surface; keep the sensing face fully exposed.
- Wiring Definition & Connection Instructions
9.1 Standard Cable Version (Suffix -E2, 2m PVC Cable, 3-wire)
| Wire Color | وظيفة | وصف |
| بني | Power Positive (الخامس+) | Connect to 10~30VDC positive terminal |
| أزرق | Power Negative (أرض) | Connect to power 0V / negative terminal |
| أسود | إخراج الإشارة (OUT) | NPN Normally Open (لا) الإخراج |
9.2 Wiring Principle of NPN NO Output
This model is NPN sinking output:
When no object is detected: Output terminal is floating, internal transistor cuts off with no signal output.
When object is detected: Internal transistor turns on, black output wire connects to blue power negative terminal and outputs low level (0V).
Typical Wiring (Connect to PLC Sinking Input)
Brown wire → 24V+ of switching power supply
Blue wire → 0V of switching power supply & PLC common terminal (كوم)
Black wire → PLC digital input terminal
Wiring for Relay / Indicator Load
One end of load connects to 24V+, the other end connects to sensor black output wire.
Sensor blue wire connects to 24V-.
Single-channel load current shall not exceed 300mA. للأحمال الحثية, connect a freewheeling diode in reverse parallel.
9.3 M12 Connector Version (Suffix -C, 4-pin Male Connector)
Pin assignment (View from sensing face, numbered clockwise):
- Pin 1: بني (قوة +)
- Pin 3: أزرق (قوة -)
- Pin 4: أسود (إخراج الإشارة)
- Pin 2: إضافي (غير مستخدمة)
- تصاعد & احتياطات الأسلاك
- Polarity Protection: Do not reverse power polarity. The built-in reverse polarity protection prevents burnout, but the sensor will not work normally under reversed connection.
- Load Limit: Maximum output load current is 300mA. Do not drive high-power loads directly; use intermediate relays for transition.
- المتطلبات البيئية: Avoid direct sunlight or strong LED light on the sensing window, and keep away from mirror or polished metal reflective surfaces in the background.
- EMC Requirements: Separate sensor cables from power cables (inverter, servo cables) with a distance of ≥20cm. Do not lay them in the same conduit.
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية