E82: 8200 سلسلة المتجهات
751: 0.75كيلوواط (75 = 0.75; the last digit 1 denotes power class)
K4: 3-phase 380~480V voltage class
ج: Basic unit, without integrated EMC filter (suffix C200 indicates version with filter)
| غرض | مواصفة |
| Rated motor power | 0.75كيلوواط (4-pole asynchronous motor) |
| Input power supply | 3-phase AC 320~550V, 45~65Hz |
| تصنيف الانتاج الحالي | 1.9أ (at 8kHz carrier frequency) |
| 60s overload current | 3.6أ (180% الزائد) |
| فئة الحماية | IP20 |
| الأبعاد الشاملة (الارتفاع × العرض × العمق) | 240 × 60 × 140 مم |
| وزن | 1.6كجم |
| Carrier frequency | 2/4/8/16kHz selectable |
| Output frequency range | 0~650Hz |
| Control modes | تحكم V/F, التحكم في ناقلات الأمراض بدون مستشعر |
| Onboard features | Brake transistor (external brake resistor ERBM370 available) |
| الإدخال/الإخراج (standard I/O module) | 5من, 1منظمة العفو الدولية, 1يفعل, 1إلى, 1 إخراج التتابع |
الميزات الوظيفية
- Built-in PID, flying restart, motor load loss monitoring, DC braking, 4 parameter set switching;
- Plug-in expansion modules: بروفيبوس, يستطيع, INTERBUS and other fieldbus modules;
- وظائف الحماية: ماس كهربائى, خطأ الأرض, الجهد الزائد/الجهد المنخفض, على درجة الحرارة, motor PTC temperature measurement, motor stall protection;
- تبريد: natural air cooling, vertical mounting; ambient temperature -10~+55℃, التخفيض مطلوب فوق 40 درجة مئوية; derate 5% for every 1000m elevation above 1000m.
التطبيقات النموذجية
المشجعين, مضخات المياه, conveyor lines, small mixers, general industrial speed regulation, التدفئة والتهوية وتكييف الهواء, آلات التعبئة والتغليف.
قطع غيار & معلومات الاستبدال
- Operator panel: لينز XT panel;
- مقاوم الفرامل: ERBM370;
- In-series alternative: E82EV751K4C200 (version with integrated EMC filter);
- Discontinuation note: ال 8200 Vector series is an obsolete model; i500 series is recommended for new unit replacement.
استكشاف الأخطاء وإصلاحها الشائعة
OC التيار الزائد: ماس كهربائى للمحرك, كابل تالف, excessive carrier frequency, short circuit in brake circuit;
OV Overvoltage: Too short deceleration time, inertial load, زيادة الشبكة;
OH Overtemperature: Dust accumulation in cooling channel, ارتفاع درجة الحرارة المحيطة, insufficient top/bottom installation clearance (≥100mm clearance reserved on top and bottom);
CINH Controller Inhibit: Disconnected enable circuit at terminal 28.
ملاحظات التثبيت
الأعلى. length of shielded motor cable: 50م (8كيلو هرتز); unshielded cable: 100م. Output du/dt filter is recommended for long motor wiring.
Lenze E82EV751K4C (8200 Vector 0.75kW, 380V) سيناريوهات التطبيق
تحديد المواقع الأساسية: Low-power general-purpose vector inverter, suitable for light constant-torque load and simple PID speed regulation. Mostly original equipment on legacy machinery, نهاية الحياة, mainly used for spare part replacement of old equipment.
- Material Conveying Industry (الأكثر شيوعًا)
Small belt conveyors, roller conveyor lines, chain feeders
سمات: ناقل بدون مستشعر, good low-speed torque; S-curve acceleration/deceleration for smooth start-stop to avoid material impact; multi-speed selection supported. Built-in brake transistor, external brake resistor can be fitted for inertial loads requiring fast deceleration.
Typical use: Infeed/outfeed belts of packaging lines, sorting branch lines, small hoists.
- ماكينات التعبئة والتغليف
Vertical form fill seal machines, ملصقات, small slitter machines, auxiliary drives for pillow packaging machines, conveyor drives
المزايا: Native PID, simple tension control with dancer roller; 4 parameter set switching for one-click recipe changeover for different products; expandable PROFIBUS/CAN bus for PLC integration.
Industry stock: Large quantity of European legacy packaging machines originally equipped with this drive.
- صناعة الطباعة (Classic OEM Model)
Auxiliary drives for Roland 700 offset presses, paper transport, delivery tray, air blowing / paper traction motors. A popular spare part model in printing machine maintenance market.
متطلبات: Stable low-speed operation, flying restart (start with rotating load); inertial load from paper rolls, fast stop achieved with brake resistor.
- التدفئة والتهوية وتكييف الهواء & Fluid (معجب & مضخة)
Small centrifugal fans, duct exhaust fans, booster pumps, metering pumps
Built-in PID for constant pressure / تدفق / التحكم في درجة الحرارة; quadratic V/F mode for energy saving; flying restart for fans still rotating after power loss.
ملحوظة: Limited 0.75kW power rating, only for small fans and pumps.
- آلات النسيج
Small spinning auxiliary machines, fabric traction rollers, guide rollers, carding auxiliary rollers, simple unwinder/rewinder
المزايا: Constant torque at low speed, low noise at 16kHz carrier frequency to reduce fabric flutter; multi-speed switching for different fabric types.
- النجارة, طعام & Pharmaceutical Standalone Small Machines
Sanding auxiliary rollers for woodworking, small mixers, mixing tanks, food conveyors, pharmaceutical bottle feeding mechanisms
Operating conditions: Continuous low-speed operation, frequent start-stop, stable torque requirement; cabinet dust protection required for dusty environments.
- Other Niche Applications
Automatic revolving door drive, test bench motor drive, small stirring equipment, laboratory speed regulation platform.
✅ Operating Boundary for Selection
- محرك: 3-phase asynchronous motor 0.75kW; 380~480V 3-phase power supply
- نوع التحميل: Light constant-torque load preferred; 180% short-time overload for max. 60ق
- غير مناسب: Heavy impact loads, high-speed servo positioning, high-precision synchronous control requiring encoder closed loop (8200 Vector is sensorless vector)
- تثبيت: تصنيف IP20, must be installed inside control cabinet, cannot be exposed directly on site.
⚠️ Industry Status
This model has been discontinued by the manufacturer for many years. Units available on market are mostly surplus stock or used reclaimed drives. Not recommended for new projects; Lenze i500 series is preferred for replacement.
I can prepare a E82EV751K4C to i500 replacement selection & parameter migration comparison table if needed.
Method to Verify Suitability of Lenze E82EV751K4C for Your Application
Core premise: This obsolete 8200 Vector 0.75kW sensorless vector inverter is only suitable for spare part replacement on legacy machines; not recommended for new project procurement.
Verification covers four aspects: load power & عزم الدوران, process control requirements, environmental & installation conditions, project type (new retrofit / maintenance spare).
- قوة & مطابقة التحميل (Primary Check)
✅ Acceptable Conditions
- Rated power of driven motor: 3-phase 0.75kW, 380V asynchronous motor; motor rated current ≤1.9A (inverter rated output current)
- Short-time overload requirement: الأعلى. 180% overload for up to 60 ثواني. Suitable for applications with mild start-stop shock and short peak load.
- Compatible load types:
✅ موصى به: Light constant-torque loads (conveyor rollers, traction rollers, small mixers), variable torque loads (مراوح صغيرة, مضخات صغيرة)
✅ Inertial loads: Paper rolls, سيور ناقلة, fast stop with external brake resistor (onboard brake transistor)
❌ Not Suitable
قوة المحرك >0.75كيلوواط; continuous heavy load, frequent heavy impact loads (الكسارات, stamping mechanisms)
Continuous overload exceeding 180% for extended duration
Quick check formula: Motor rated current ≤ inverter rated output current 1.9A
- Process Control Requirement Check
✅ Processes compatible with this inverter
- Speed regulation: 0~650Hz speed range, sensorless vector without encoder, decent low-speed torque; no high-precision position synchronization required
- Logic functions: Multi-speed selection, built-in PID closed loop (pressure/flow/simple tension), flying restart, DC braking, 4 parameter set switching (multi-product recipe)
- تواصل: Expandable PROFIBUS / CAN bus modules for PLC connection; basic DI/DO analog terminal control
- Start-stop: S-curve acceleration/deceleration to reduce mechanical shock, ideal for conveying and packaging auxiliary equipment
❌ Unsuitable Applications
- Applications requiring encoder closed loop, high precision positioning, multi-axis electronic cam, التحكم المتزامن (functions of servo or high-end vector drives, 8200 Vector does not support encoder interface)
- High-precision tension unwinding/rewinding, main drive of high-speed precision printing machines
- Operating conditions requiring fast dynamic response and frequent acceleration/deceleration under heavy load
ثالثا. البيئية, تثبيت & Electrical Conditions
✅ Acceptable
- مزود الطاقة: 3-phase AC320~550V, 45~65Hz
- تثبيت: داخل خزانة التحكم (IP20); full power at ambient temperature -10℃ ~ +40℃, derating required at 40~55℃; elevation ≤1000m, ديراتي فوق 1000 م
- تراب: Cabinet dust protection required; not for open-air, رطوبة عالية, بيئات الغاز المسببة للتآكل
- Motor cable: الأعلى. 50m shielded cable (8كيلو هرتز); output du/dt filter required for long motor cables
❌ Not Acceptable
Direct outdoor installation, رطوبة عالية, strong corrosion, heavy metallic dust environment
Excessively long motor cable without output filter
- Project Type Assessment (شديد الأهمية)
✅ Suitable: Spare part replacement, old equipment maintenance
Original machine is factory fitted with E82EV751K4C. Direct same-model replacement, parameters/program can be copied without mechanical or electrical control modification.
العيب: Available stock is surplus or used, unstable lead time, no original manufacturer warranty.
❌ Not Recommended: مشاريع جديدة, complete machine retrofit
New projects should adopt Lenze i500 series (i510 / i550), better performance, full new warranty, stable spare part supply.
✅ Quick Self-Check Checklist (Tick boxes)
Motor is 3-phase 380V asynchronous motor, rated power 0.75kW, rated current ≤1.9A
الأعلى. short-time load does not exceed 180% and lasts less than 60 ثواني
Only speed regulation and simple PID required, no encoder closed-loop positioning
Inverter mounted inside control cabinet, ambient temperature ≤40℃
Application is legacy equipment maintenance spare replacement, not new machine development
✅ All boxes ticked: E82EV751K4C can be used;
❌ Any box fails: Not recommended, select different power rating or switch to i500 and other new models.
تكميلية: Replacement Selection Reference
If requirements are not met, Lenze i500 series (i510 / i550, 0.75كيلوواط, 380V) هو المفضل. Parameter migration supported, more bus options, optional integrated EMC filter, new units readily available.
لينز 8200 ناقل (E82EV) قائمة النماذج الكاملة
Series full name: E82EV = 8200 Vector vector inverter, IP20 built-in unit, 0.25~90kW, توقف
شرح اللاحقة:
ك2: Single/3-phase 230V; K4: 3-المرحلة 380 ~ 480 فولت
ج: Small power housing (0.25~11kW); ب: High power housing (15~90kW)
C200 = Version with integrated EMC filter; base C version without EMC filter (E82EV751K4C in your query is base version without filter)
- 230الفئة الخامسة (ك2, single-phase input, 0.25~7.5kW)
| نموذج | قوة |
| E82EV251K2C | 0.25كيلوواط |
| E82EV371K2C | 0.37كيلوواط |
| E82EV551K2C | 0.55كيلوواط |
| E82EV751K2C | 0.75كيلوواط |
| E82EV152K2C | 1.5كيلوواط |
| E82EV222K2C | 2.2كيلوواط |
| E82EV302K2C | 3.0كيلوواط |
| E82EV402K2C | 4.0كيلوواط |
| E82EV552K2C | 5.5كيلوواط |
| E82EV752K2C | 7.5كيلوواط |
- 400الفئة الخامسة (K4, 3-المرحلة 380 ~ 480 فولت, 0.55~11kW, C housing)【Focus, E82EV751K4C belongs to this group】
| نموذج | قوة |
| E82EV551K4C | 0.55كيلوواط |
| E82EV751K4C | 0.75كيلوواط |
| E82EV152K4C | 1.5كيلوواط |
| E82EV222K4C | 2.2كيلوواط |
| E82EV302K4C | 3.0كيلوواط |
| E82EV402K4C | 4.0كيلوواط |
| E82EV552K4C | 5.5كيلوواط |
| E82EV752K4C | 7.5كيلوواط |
| E82EV113K4C | 11كيلوواط |
ثالثا. 400الفئة الخامسة (K4, 3-المرحلة 380 ~ 480 فولت, 15~90kW, B housing)
| نموذج | قوة |
| E82EV153K4B | 15كيلوواط |
| E82EV223K4B | 22كيلوواط |
| E82EV303K4B | 30كيلوواط |
| E82EV453K4B | 45كيلوواط |
| E82EV553K4B | 55كيلوواط |
| E82EV753K4B | 75كيلوواط |
| E82EV903K4B | 90كيلوواط |
✅ Derivative Variants (نفس القوة, different suffix)
- C200 version: Add C200 suffix for same power model, integrated EMC filter, example: E82EV751K4C200
- Safe-Standard safe torque off version: suffix 4xx, على سبيل المثال. E82EVxxxKxC400 (available for 3~11kW)
- Coated PCB version: PCB conformal coating for humid and dusty environments, suffix xxx1
- E82DV / E82CV: نفس 8200 سلسلة المتجهات, different mounting construction:
E82DV: Through-panel mounting
E82CV: Cold plate cooling type (base plate heat dissipation), power range same as E82EV
📌 Optional Accessories List (E82Z series accessories)
E82ZAFSC010: Standard I/O terminal module (E82EV main unit requires this I/O board for operation)
E82ZBC: Basic operator panel; EMZ9371BC: XT advanced panel
E82ZAFPC010: Profibus DP communication module
E82ZAFCC010: CANopen communication module
E82ZLxx: Line reactor
ERBM / ERBD: Matching brake resistor
⚠️ Remarks
- The entire 8200 Vector series has been discontinued by OEM. i500(i510/i550) is recommended for new projects;
- Small power E82EV (0.25~11kW) housing size increases with power rating, all IP20; B housing for 15kW and above with larger dimension;
- C and C200 versions of same power have identical electrical performance, difference only in EMC filter. Interchangeable for spare replacement, EMC compliance needs to be considered.
المقاولين,قاطع الدائرة,الاستشعار,التشفير,بلك,محول

















NH42-63-318x560.png)