Mitsubishi AJ65SBTB1-16D Remote I/O Unit Series - المقاولين,قاطع الدائرة,الاستشعار,التشفير,بلك,محول

ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

 Mitsubishi AJ65SBTB1-16D Remote I/O Unit Series - المقاولين,قاطع الدائرة,الاستشعار,التشفير,بلك,محول

بلك/

Mitsubishi AJ65SBTB1-16D Remote I/O Unit Series

AJ65: CC-Link remote I/O unit series SBT: CC-Link remote module B1: Compact terminal block type 16D: 16-point DC digital input module (الإدخال الرقمي) تحديد المواقع: CC-Link remote input station, احتلال 1 station address. It is used for remote DI signal acquisition, compatible with Q/A/L series master PLCs, and is one of the most widely used remote ...

  • تفاصيل المنتج

AJ65: CC-Link remote I/O unit مسلسل

SBT: CC-Link remote module

B1: Compact terminal block type

16د: 16-point DC digital input module (الإدخال الرقمي)

تحديد المواقع: CC-Link remote input station, احتلال 1 station address. It is used for remote DI signal acquisition, compatible with Q/A/L series master بلكق, and is one of the most widely used remote DI modules for CC-Link fieldbus.

المواصفات الفنية الأساسية

غرضالمعلمة
نقاط الإدخال/الإخراج16-point DC24V input
Input Ratingتيار مستمر 24 فولت; allowable voltage range: DC19.2~26.4V, ripple ≤5%; input current per point approx. 7أماهMITSUBISHI…
ON Condition≥14V / ≥3.5mA; OFF Condition: ≤6V / ≤1.7mAMITSUBISHI…
Input Response Time≤1.5ms (ON↔OFF)
المحطة المشتركةSink/source compatible (supports both NPN and PNP sensors); 1 common terminal for all 16 نقاط; single-row terminal block
عزلPhoto-coupler isolation
Station Occupancy1 station
Module Power Supplyتيار مستمر 24 فولت; استهلاك الطاقة تقريبا. 35mAMitsubishi…
الأبعاد الشاملةW118 × H50 × D40 mm; الوزن تقريبا. 0.18kgMitsubishi…
الظروف المحيطةدرجة حرارة التشغيل: 0~55℃; درجة حرارة التخزين: -20~75℃; humidity 10~90%RH (لا التكثيف)
الشهاداتأول, طريق مسدود, م, بنفايات, كانساس

إرشادات الأسلاك

  1. كتلة المحطة الطرفية: 16 DI channels + COM terminal. COM supports both positive and negative common, so NPN and PNP sensors can be wired directly.
  2. Bus terminals: و, ديسيبل (CC-Link signal lines) + FG shield earth.
  3. مزود الطاقة: Module powered by DC24V. Use the same power supply for the module and sensors, and keep common ground.
  4. Terminating resistor: Install 110Ω CC-Link terminating resistor at the first and last stations on the bus.
  5. Station address setting: Set the CC-Link station number (1~64) via the DIP switch on the side of the module; settings take effect after power cycle.

سيناريوهات التطبيق

Distributed DI acquisition on production lines: أجهزة الاستشعار الكهروضوئية, مفاتيح القرب, أزرار الضغط, limit switches and E-stop signals collected remotely.

Cabinet split wiring: Main PLC installed in central control cabinet; AJ65SBTB1-16D mounted locally on equipment control boxes to eliminate long-distance multi-core cables, only one CC-Link bus cable is needed.

Compatible master stations: س, أ, L series PLCs (with CC-Link master modules QJ61BT11N / AJ61BT11, إلخ.)

برامج البرمجة: GX Works2 / جي اكس وركس3. Configure remote I/O stations in CC-Link network parameters; remote input soft elements are assigned automatically.

استكشاف الأخطاء وإصلاحها

  1. RUN indicator off: Check DC24V power supply and polarity.
  2. LERR indicator flashing: Duplicate station number, bus breakage, DA/DB reversed, المقاوم إنهاء مفقود, or communication interference.
  3. No input signal: Check sensor power supply, COM wiring, input voltage, or damaged optocoupler.
  4. Input permanently ON: Shorted sensor or short circuit to ground on field wiring.

استبدال & Cross-model Reference

AJ65SBTB1-16D1: 16DI with faster 0.2ms response (high-speed version).

AJ65SBTB1-32D: 32-point DC input (same series, 1 station occupied).

AJ65SBTB1-16DT: Mixed 8DI+8DO I/O module.

New generation replacement: NZ2GF2B1-16D (CC-Link IE Field Basic remote DI, recommended for new projects).

Engineering Application Cases for AJ65SBTB1-16D

تحديد المواقع الأساسية: 16-point DC24V digital input remote station over CC-Link, distributed field DI collection to reduce extensive hardwiring. Compatible master stations: Q/L/A series PLC + QJ61BT11N, FX3U+FX3U-16CCL-M, FX5+FX5-CCL-MS; one module occupies one CC-Link station address.

قضية 1: Pushrod Accumulating Conveyor with Wire Breakage Detection (Diagnostic Type)

  1. Transistor Output Modules (يفعل, تي = الترانزستور, Sink/NPN Type)

8-point Output

  1. AJ65SBTB1-8T: 8-point transistor output, 1.5ms response
  2. AJ65SBTB1-8T1: 8-point low leakage current version
  3. AJ65SBTB1-8TE: 8-point with protective circuit

16-point Output

  1. AJ65SBTB1-16T: 16-point standard transistor output
  2. AJ65SBTB1-16T1: 16-point low leakage current version

32-point Output

  1. AJ65SBTB1-32T: 32-point transistor output
  2. AJ65SBTB1-32T1: 32-point low leakage current
  3. AJ65SBTB1-32TE1: 32-point enhanced protection version

ثالثا. Mixed I/O Modules (DI+DO, DT=Input+Output)

16-point Mixed (8د + 8 ج)

  1. AJ65SBTB1-16DT: Standard 8DI+8DO
  2. AJ65SBTB1-16DT1: High-speed response version
  3. AJ65SBTB1-16DT2: With wire breakage diagnosis
  4. AJ65SBTB1-16DT3: High-reliability revised version (most popular new model)

32-point Mixed (16د + 16 درجة مئوية)

  1. AJ65SBTB1-32DT: Standard 16DI+16DO
  2. AJ65SBTB1-32DT1: High-speed version
  3. AJ65SBTB1-32DT2: With wire breakage detection (KDT type)
  4. AJ65SBTB1-32KDT2: Wire breakage diagnosis + حماية ماس كهربائى
  5. AJ65SBTB1-32KDT8: 32-point mixed, high diagnostic grade
  6. AJ65SBTB1-32DT3: Revised stable model
  7. AJ65SBTB1-32DTE1: With surge absorption protection-
  8. Suffix Code Rules (Quick Identification)

لا لاحقة: Standard response time 1.5ms

1: استجابة عالية السرعة (0.2آنسة); low leakage current output

2: Wire breakage diagnosis function

3: Revised circuit, improved anti-interference performance

ك: Wire breakage detection (diagnostic module)

ه: Output surge protection added

  1. Distinction Between Adjacent Series (Avoid Wrong Selection)
  2. AJ65SBTB1: Single-row terminal block, compact type (this series)
  3. AJ65SBTB2: Double-row terminals, higher output current
  4. AJ65SBT32: Large-size 32-point remote I/O
  5. AJ65SBTC1/C4: Spring-cage terminals (plug-in type, not part of TB1 series)
  6. Simplified Selection Table for Project Use
طلبالنموذج المفضلHigh-speed Alternative
16-point DI collectionAJ65SBTB1-16DAJ65SBTB1-16D1
32-point DI collectionAJ65SBTB1-32DAJ65SBTB1-32D1
16-point DO outputAJ65SBTB1-16TAJ65SBTB1-16T1
8DI+8DO mixed I/OAJ65SBTB1-16DT3AJ65SBTB1-16DT2
16DI+16DO mixed I/OAJ65SBTB1-32DT3AJ65SBTB1-32KDT2