OMRON F3SG-4RE1630P30 Safety Light Curtain

Application Scenarios of OMRON F3SG-4RE1630P30 (1630mm Height, 30mm Hand Protection, Type4 PL e) This light curtain features 1.63m protective height and 30mm detection resolution dedicated to hand protection, with highest safety Category 4 / سيل 3. It has no muting function and only basic OSSD outputs, suitable for equipment requiring physical barrier to stop hands ...

  • تفاصيل المنتج

Application Scenarios of اومرون F3SG-4RE1630P30 (1630mm Height, 30mm Hand Protection, Type4 PL e)

This light curtain features 1.63m protective height and 30mm detection resolution dedicated to hand protection, with highest safety Category 4 / سيل 3. It has no muting function and only basic OSSD outputs, suitable for equipment requiring physical barrier to stop hands entering hazardous areas, covering machining, الأتمتة, اللوجستية, rubber & بلاستيك, robot industries:

  1. Stamping & Forging Equipment (Core High-Risk Applications)
  2. Safety protection for operating openings of air/hydraulic presses
  3. Safety isolation at feed inlets of press brakes & plate shears
  4. Material pick-up stations for hot & cold forging machines

سمات: 1630mm height fully covers hand intrusion range of standing operators; configurable with manual reset + EDM monitoring to meet machine tool safety standards.

انهيار رمز النموذج

نموذج: F3SG-4RE1630P30

شريحةشفرةتعريف
F3SGمسلسلF3SG-R Basic Safety Light Curtain (Entry-level model; no muting, no cascade function)
4Safety Typeيكتب 4 highest safety rating, بل ه / سيل 3 / فئة 4
RESub-seriesRE = Basic simplified version; no muting, no cascade, no beam coding, only basic safety outputs
1630Protected HeightEffective protective height: 1630 مم
صنوع الإخراجDual PNP OSSD safety outputs
30دقة30mm hand protection, beam pitch 20mm, minimum detectable opaque object: φ30mm
  1. Core Electrical & مواصفات السلامة

2.1 Mandatory Safety Certifications

اللجنة الانتخابية المستقلة 61496-1: يكتب 4

ايزو 13849-1: بل ه / فئة 4

اللجنة الانتخابية المستقلة 61508: سيل 3

متوافق مع EN 60204-1, فئة 0 machine safety stop

2.2 Optical Detection Parameters

Protected Height: 1630 مم

Beam Pitch: 20 مم

Total Beams: 80 beams

Minimum Detectable Opaque Object: φ30 mm (hand protection grade)

Detection Range: 0.3 m ~ 20 م

Maximum Response Time: 9 آنسة

Synchronization: Optical synchronization, no dedicated sync wiring required

2.3 المعلمات الكهربائية

جهد الإمداد: 24 VDC ±20% (SELV Safety Extra Low Voltage)

Safety Outputs: 2-channel PNP OSSD, max load per channel: 300 أماه

Residual Voltage: ≤2 V

التسرب الحالي: ≤1 mA

Transmitter Current Draw: ≤120 mA; Receiver Current Draw: ≤150 mA

موصل: M12 straight plug; Transmitter: 5-دبوس, Receiver: 8-دبوس, factory fitted with 0.3m short cable

2.4 البيئية & الخواص الميكانيكية

البعد الشامل: 35(دبليو) × 35(ح) × 1630(ل) مم

حماية الدخول: IP67 (when connectors fully tightened)

درجة حرارة التشغيل: -10 ℃ ~ +55 درجه مئوية

درجة حرارة التخزين: -25 ℃ ~ +70 درجه مئوية

رطوبة: 35%~85% RH, غير التكثيف

مقاومة الاهتزاز: 10~55 هرتز, amplitude 0.7mm, 20 cycles per 3 محاور

مقاومة الصدمات: 100 م/ث², 1000 shocks per 3 محاور

مواد الإسكان: PBT engineering plastic; Optical window: PC polycarbonate

الوزن الصافي (Transmitter + Receiver Set): ~1.2 kg

  1. وصف الوظيفة (Limitations of RE Basic Series)

✅ Standard Built-in Functions

  1. Two independent OSSD safety outputs; outputs cut off immediately upon beam occlusion
  2. DIP switch selectable: Auto-reset / Manual-reset, EDM external device monitoring enable/disable
  3. أحمر & Green LED status indicators (قوة, Sync, Occlusion, Fault)
  4. Long-distance mode optimized for detection range 10~20 m

❌ Unsupported Functions (Not available on RE basic model)

Muting function

Multi-unit cascade connection

Anti-interference beam coding

Auxiliary signal output (only dual safety outputs available)

  1. M12 Connector Pin Definition

Transmitter (5-pin M12)

1: 24V DC+

2: 0V GND

3: Optical Sync

4: غير مستخدمة

5: درع

Receiver (8-pin M12)

1: 24V DC+

2: 0V GND

3: OSSD1 PNP Output

4: OSSD2 PNP Output

5: EDM Monitoring Input

6: Reset Input

7: Optical Sync

8: درع

  1. سيناريوهات التطبيق النموذجية
  2. Perimeter safety protection for industrial robot workcells
  3. Hand protection for stamping & injection molding machine operating zones
  4. Safety isolation at inlet/outlet of automated conveyor lines
  5. Human intrusion detection for large machine tools & assembly lines with 1.6m protective height
  6. Safety light curtain for AGV traffic aisles in warehouses
  7. Optional Matching Accessories (Ordered Separately)
  8. F39-JD□RA: M12 extension cables (5m/10m/20m)
  9. F39-BT Standard Mounting Bracket, F39-BTLP Long Bracket
  10. F39-SG Splash Guard (for environments with cutting fluid & غبار كثيف)
  11. F39-LZ Laser Alignment Tool (fast calibration for long-distance installation)
  12. Alternative Replacement Models
  13. Direct drop-in equivalent (same specs): F3SG-4RE1630N30 (NPN output version)
  14. Upgraded SR series (long-term supply recommended): F3SG-4SR1630-25 (يكتب 4, وظائف محسنة, supports muting & cascade)
  15. Lower safety Type 2: F3SG-2RE1630P30 (ب ل د, not applicable for high-risk pressing machinery)
  16. تثبيت & Commissioning Guidelines
  17. Minimum mounting distance between light curtain and hazard zone ≥0.3m; calculate safety distance matching machine braking time
  18. Optical alignment after installation: steady green LED = normal operation; flashing LEDs indicate misalignment or out-of-range distance
  19. EDM external monitoring must be enabled for high-risk equipment to detect safety relay contact welding faults
  20. Reset mode configuration: Manual reset mandatory for presses/stamping machines; auto-reset allowed for conveyor lines
  21. Avoid direct intense light irradiation on optical windows to prevent infrared interference and false triggering
  22. Quick Troubleshooting Matrix
ظاهرة الخللالسبب الجذريحل
Steady red LED, no safety outputBeam occlusion, misaligned transmitter/receiver, broken cableClean optical window, realign light curtain, inspect M12 connectors
Alternating red & green flashingDistance out of 0.3~20m range, strong light interferenceShorten installation distance, install light shield, activate long-distance DIP switch
Locked state after power-up, cannot resetOpen EDM circuit, incorrect DIP switch settingsCheck feedback wiring of safety relay, reset DIP switches
Safety outputs fail to cut off loadالحمل الزائد الحالي, inductive load without freewheeling diodeReduce load current, install freewheeling diode parallel to inductive loads

 

Injection Molding & Die Casting Equipment

  1. Open pick-up ports replacing safety doors for vertical & horizontal injection molding machines
  2. Feeding & part extraction windows for aluminum & zinc alloy die-casting machines
  3. Operating station isolation for rubber vulcanizers & بثق

طلب: Manual loading/unloading of mold products, preventing hands entering clamping & extrusion hazard zones.

  1. Machining Industry
  2. Open loading/unloading channels for CNC milling machines & مراكز التصنيع
  3. Manual feed side protection for lathes, المطاحن & band saws
  4. Manual loading stations for sheet metal & fiber laser cutters

المزايا: IP67 dust & liquid resistance, tolerates cutting fluid and metal dust; 30mm resolution prevents finger intrusion into cutting tool hazard zones.

  1. Industrial Robot Workcells
  2. Access gates of 6-axis robot handling & assembly safety fences
  3. Manual intervention channels for palletizing & welding robots
  4. Safety passages for robot grinding & coating stations

وصف: 1.63m height fits adult standing passage; power cut-off for robots upon personnel intrusion, complies with PL e machinery safety requirements.

  1. Automated Conveying & Packaging Lines
  2. Inlet & outlet protection for carton sealers & آلات التعبئة والتغليف
  3. Hazard zone isolation for stretch wrapping & pallet strapping machines
  4. Separation stations of production lines & manual sorting workstations
  5. Dual-side safety light curtains for AGV & forklift traffic aisles

Working Condition: Auto-reset configurable for assembly lines; machine stops upon accidental intrusion and resumes automatically after personnel leave.

  1. بطارية الليثيوم & 3C Electronic Automation Equipment
  2. Manual operation windows for battery slitting & آلات اللف
  3. Feed inlets of phone housing CNC & pressing equipment
  4. Open stations for battery testing & assembly machines

المزايا: 24V SELV low voltage eliminates electric leakage risk; low electromagnetic interference compatible with precision electronics production lines.

  1. Warehouse & Logistics Lifting Equipment
  2. Side safety protection for small freight elevators & lifts
  3. Manual access openings of automated racking systems
  4. Hazard gap isolation for roller conveyors & transfer machines
  5. Wood & Stone Processing Machinery
  6. Feed inlet protection for sliding table saws, sanders & stone cutting machines
  7. Operating zone isolation for wood door & panel polishing equipment

Unsuitable Application Scenarios (Limitations of RE Series)

  1. Processes requiring material passing through protective area (Muting function unavailable; machine stops when any workpiece passes, F3SG-SR series recommended instead)
  2. Multi-curtain splicing via cascade connection (RE series does not support cascade)
  3. Long-term vehicle & large workpiece access passages (Muting function mandatory to avoid frequent unexpected shutdowns)

Response Time Parameters of OMRON F3SG-4RE1630P30

  1. Maximum Response Time: 9 آنسة
  2. Supplementary Explanation:

This value refers to total full response duration for the complete set (transmitter + receiver) to cut off OSSD safety outputs

This model has 1630mm protective height with a large number of beams, representing the upper response time limit within the same RE series

The maximum value of 9ms must be adopted for safety distance calculation, typical values cannot be used

Total system stop reaction time after pairing with safety relay = 9ms (curtain) + safety relay actuation time

Model Selection Tips

If ultra-fast braking speed is required, select shorter protective height models from the same RE series; fewer beams deliver faster response speed.