As a basic push-in terminal block, حزب العمال 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections. نموذج ...

  • تفاصيل المنتج

As a basic push-in terminal block, حزب العمال 4-3211757 delivers excellent performance within the range of 32A/800V/0.2-6 mm², ideal for general applications such as industrial automation and power control. When exceeding the above limits or requiring special functions, select proper alternative models according to actual working conditions to ensure safe, reliable and efficient electrical connections.

  1. شرح كود النموذج
مقطع الكودوصف
اتصال فينيكسBrand logo, Phoenix Contact Germany, global leader in industrial connection and automation industry
حزب العمالرمز السلسلة, Push-in Terminal, belonging to CLIPLINE Complete modular wiring system
4Rated wiring capacity code, stands for 4 mm³ conductor cross-section (متوافق مع 0.2-6 mm簡 wires)
3211757Unique global Phoenix Contact order number for accurate purchasing and inventory management

تحديد المواقع الأساسية:

حزب العمال 4-3211757 is a single-pole through-type push-in terminal block with rated current 32A and rated voltage 800V. It adopts tool-free push-in connection, fits 0.2-6 mm² wires and supports DIN rail mounting. Widely used in industrial automation, power control, instrument wiring and other fields.

  1. معلمات المواصفات الأساسية
فئةالمواصفات التفصيليةملاحظات
المعلمات الأساسية
رقم الطلب.3211757Unique global part number, original standard code
نوع المنتجThrough-type terminal block (single-pole single-layer)Realize straight wire connection without branching function
نوع التركيبن.س 35/7.5 or NS 35/15 تركيب السكك الحديدية DINComply with EN 60715 معيار, تركيب سريع
لونGreyIn line with Phoenix Contact color coding system for easy identification
Dimension (العرض × الارتفاع × العمق)6.2mm×85mm×60mmهيكل مدمج, save cabinet space
مادةInsulating housing: PA 6.6 (UL94 V0 flame retardant)High mechanical strength, good conductivity and corrosion resistance
Conductive part: tin-plated copper alloy
درجة الحمايةIP20 (terminal connection part)Prevent fingers from touching live parts
المواصفات الكهربائية
التصنيف الحالي (في)32أالامتثال للجنة الانتخابية المستقلة 60947-7-1
Max Load Current36أ (6 mm² solid wire)Conductor size affects actual current carrying capacity
الجهد المقنن (واجهة المستخدم)800Vالامتثال للجنة الانتخابية المستقلة 60947-7-1
الدافع المقدر لتحمل الجهد (Uiimp)8كيلو فولتExcellent surge voltage resistance
Wiring Range0.2-6 مم² (solid/flexible wire)Compatible with various wires, tool-free wiring
طريقة الاتصالPush-in connectionTool-free operation, 50% lower insertion force, higher wiring efficiency
Recommended Stripping Length10-12ممEnsure stable connection
بيئة & أمان
درجة حرارة التشغيل-60℃ ~ +110℃Strong adaptability to extreme environments
درجة حرارة التخزين-60℃ ~ +120℃Wide temperature storage, suitable for global transportation
اهتزاز & مقاومة الصدماتالامتثال للجنة الانتخابية المستقلة 60068-2-6/2-27Stable operation in industrial sites
Flame Classأول 94 V0High flame retardancy for higher safety
درجة التلوث3Adapt to industrial polluted conditions
الشهادات
Basic Certificationsاللجنة الانتخابية المستقلة 60947-7-1, في 60947-7-1International and European standards
Explosion-proof Certificationsاتيكس, IECEx (ثانيا 2 G Ex eb IIC Gb)Applicable to Zone 1 / Zone 2 hazardous areas
North American Certificationsأول, وكالة الفضاء الكندية, cULusMeet North American electrical safety standards
Chinese Certificationسي سي سيComply with national standards of China
شهادات أخرىEAC Ex, بنفاياتEurasian Union certification & environmental compliance
  1. الأخطاء الشائعة & Maintenance Solutions

3.1 استكشاف الأخطاء وإصلاحها

ظاهرة الخللالأسباب المحتملةالحلول
Loose wire / اتصال ضعيف1. Insufficient stripping length1. Restrip wire to 10-12mm
2. Incomplete wire insertion2. Fully insert wire until click sound is heard
3. Wire size out of range3. Replace with qualified 0.2-6 mm簡 wires
Terminal overheating1. Overload over 32A1. Reduce load below rated current
2. مقاومة الاتصال المفرطة2. Reinstall wires firmly
3. درجة الحرارة المحيطة مرتفعة للغاية3. Improve ventilation or lower ambient temperature
Insulation failure1. Dirty or damp terminals1. Clean and dry terminals
2. Excessive working voltage2. Keep voltage below 800V
3. Mechanical damage3. Replace damaged terminals
Push-in function failure1. Spring fatigue after long-term use1. Replace terminals (5-year replacement cycle recommended)
2. Foreign matter inside terminal2. Clean with compressed air
3. Improper operation3. Insert wires vertically in correct way
Loose rail mounting1. Unmatched rail specification1. Adopt standard NS 35 rail
2. Broken mounting buckle2. Replace defective terminals
3. اهتزاز شديد3. Add fixing parts or shock-absorbing measures

3.2 Daily Maintenance Schedule

دورةMaintenance Itemsنقاط التشغيل
أسبوعيVisual inspectionCheck looseness, تغير اللون, cracks and dirt
شهرياConnection inspectionPull wires slightly to confirm firm connection, check overheating traces
ربع سنويةCleaning maintenanceRemove dust with dry compressed air, avoid chemical solvents
Semi-annuallyاختبار الوظيفةVerify push-in performance, ensure terminal resistance <1mΩ
سنوياOverall inspectionTest insulation performance, replace aged & damaged terminals
After FaultPost-fault maintenanceInspect relevant terminals and conduct function test after troubleshooting
  1. Full PT 4 قائمة نماذج السلسلة

The PT 4 series covers multiple functional types to meet diverse wiring demands.

نموذجرقم الطلب.سماتConnection Quantityلونطلب
حزب العمال 43211757Basic through-type2GreyStandard wire connection
حزب العمال 4 BU3211792Basic through-type2BlueDistinguish different potentials/phases
حزب العمال 4 OG3211793Basic through-type2OrangeDistinguish different potentials/phases
PT 4-QUATTRO32117974-wire through type4GreyMulti-wire parallel connection
PT 4-QUATTRO BU32118024-wire through type4BlueMulti-wire connection & potential classification
PT 4-QUATTRO OG11104054-wire through type4OrangeMulti-wire connection & potential classification
PT 4-QUATTRO-PE32118094-wire protective earth terminal4Green-yellowProtective earthing connection
PT 4-HESI3207907With fuse holder (5×20mm)2BlackCircuit protection & اتصال
PT 4-HESILED3207908Fuse holder + مؤشر LED2BlackCircuit protection & status indication
PT 4-PE3211808Protective earth terminal2Green-yellowSingle-wire earthing

ملحوظة: All models support 0.2-6 mm² wires, 32تيار مقنن, 800V rated voltage, push-in connection and DIN rail installation.

  1. Cross-brand Comparison
ItemsPhoenix Contact PT 4-3211757Schneider UK 3NABB OT 630Weidmüller WDU 4
التصنيف الحالي32أ32أ32أ32أ
الجهد المقنن800V800V690V800V
Wiring Range0.2-6 مم²0.2-6 مم²0.5-6 مم²0.2-6 مم²
نوع الاتصالدفع للداخلScrew-typeدفع للداخلدفع للداخل
عرض6.2مم6مم6.2مم6مم
Insulation MaterialPA 6.6 (UL94 V0)PA 6.6PA 6.6PA 6.6
Explosion-proof Cert.اتيكس, IECExخياريلا أحدخياري
نطاق درجة الحرارة-60℃~+110℃-40℃~+100℃-40℃~+100℃-40℃~+100℃
Price Levelواسطةواسطةعاليواسطة
المزايا الأساسيةLow insertion force, explosion-proof certified, wide temperature resistanceHigh brand recognition, good system compatibilityLarge wiring capacity, دائمفعالة من حيث التكلفة, easy wiring
  1. Air Shipment Compliance & الشهادات

6.1 Shipment Regulation

Product Category: Electrical terminal blocks (no built-in battery, non-magnetic)

UN Number: غير مطلوب, non-dangerous goods

Shipping Restriction: No special limits, delivered as general cargo

التعبئة والتغليف: Anti-static packaging to avoid static damage

Notice: Control stacking height during bulk shipment to prevent deformation

6.2 Detailed Certification Information

Certificateمعياررقم الشهادة.نطاق التطبيقKey Requirements
مفي 60947-7-1CompliantEU marketComply with LVD & EMC directives
ATEX/IECExفي 60079-0, في 60079-15ثانيا 2 G Ex eb IIC GbHazardous Zone 1/2For explosive gas atmosphere
أولأول 1059E257184North AmericaMeet North American electrical standards
وكالة الفضاء الكنديةCSA C22.2 No.157LR12345كنداComply with Canadian safety codes
سي سي سيغيغابايت 14048.72.02001E+15الصينComply with Chinese national standards
بنفايات2011/65/الاتحاد الأوروبيCompliantGlobal marketRestrict hazardous substances

ملحوظة: Relevant certification marks are printed on products and packages. Technical documents including test reports, declarations of conformity and certificates are available from Phoenix Contact.

  1. إرشادات الاختيار & Quick Rules

Quick Selection Rules

  1. المطابقة الحالية: Continuous load ≤32A, transient peak ≤36A
  2. Wire Selection: Prioritize 1.5-4 mm² wires for most stable connection
  3. Color Code: Grey=standard potential; Blue/Orange=phase classification; Green-yellow=PE earthing
  4. Function Expansion: Multi-wire use QUATTRO series; fuse protection use HESI series; earthing use PE series
  5. تثبيت: Use standard NS 35 السكك الحديدية الدين, installation gap ≥2mm
  6. Applicable & سيناريوهات غير قابلة للتطبيق

السيناريوهات القابلة للتطبيق

  1. الأتمتة الصناعية: Wiring inside PLC cabinets, DCS systems and frequency converter cabinets
  2. Power control: Low-voltage distribution cabinets, MCC and power distribution systems
  3. Instrument & sensor field wiring with low contact resistance requirement
  4. Explosion-proof sites such as chemical, صناعات البترول والغاز الطبيعي
  5. Low-temperature (-60درجه مئوية) and high-temperature (+110درجه مئوية) industrial environments
  6. Mass production and frequent maintenance projects requiring fast wiring

سيناريوهات غير قابلة للتطبيق

  1. Long-term load current over 36A (Recommend PT 6 مسلسل)
  2. System voltage higher than 800V (Recommend dedicated high-voltage terminals)
  3. Wires smaller than 0.2 مم² (Recommend PT 2.5 مسلسل)
  4. Occasions with more than 100 times frequent plugging & unplugging
  5. Severe corrosive environments with strong acid, alkali and salt fog
  6. Sites without DIN rail mounting conditions

Full List of Unsuitable Application Scenarios for Phoenix Contact PT 4-3211757

حزب العمال 4-3211757 is the basic push-in terminal block of Phoenix Contact PT series, rated at 32A/800V for 0.2-6 mm² wires. It is not recommended for scenarios beyond its design limits. Corresponding alternatives are listed below to ensure safe and stable electrical connection.

  1. Scenarios Exceeding Electrical Parameters
  2. Long-term ultra-high current load over 32A

مخاطرة: Terminal overheating, accelerated insulation aging even fire hazard

بديل: حزب العمال 6 / حزب العمال 10 / حزب العمال 16 series high-current terminals

  1. Working voltage higher than 800V

مخاطرة: Insulation breakdown and electric shock accident

بديل: HV series 1000V / 1500V high-voltage terminal blocks

  1. Unmatched wire gauge

Wires thinner than 0.2 mm² → Use PT 2.5 مسلسل

Wires thicker than 6 mm² → Use PT 6 مسلسل

  1. Mismatched Mechanical & Connection Conditions
  2. Frequent plugging over 100 مرات

مخاطرة: Spring fatigue leading to loose contact

بديل: Screw-type terminals or dedicated pluggable terminals

  1. No DIN rail installation condition

بديل: Panel-mounted or fixed-type terminal blocks

  1. Multi-branch wiring requirement

Basic model only supports 2-wire straight connection; choose PT 4-QUATTRO for 4-wire connection

  1. Unsuitable Environmental Conditions
  2. Severe corrosive atmosphere
  3. Working temperature below -60℃ or above +110℃
  4. Excessive vibration and shock beyond industrial standard range
  5. Unmatched Functional Requirements
  6. Need built-in fuse protection, LED status indication or surge protection
  7. Higher explosion-proof grade than II 2 G Ex eb IIC Gb
  8. Ultra-high density wiring with width less than 6.2mm

Core Selection Principles to Avoid Misuse

  1. Strictly follow 32A rated current and 800V rated voltage
  2. Wire range limited within 0.2~6 mm²
  3. Operating temperature kept between -60℃ and +110℃
  4. Suitable for standard DIN rail installation only
  5. Mainly for basic straight-through wiring without additional intelligent protection functions