PNOZ m B0 772138
ماركة: فطر (فطر, ألمانيا)
سلسلة المنتجات: PNOZmulti Modular Safety Relay / Programmable Safety Controller
✅ Model Description
PNOZ m: PNOZmulti modular safety system
B0: الوحدة الأساسية (main controller body, no expansion modules included)
772138: Material number
📋 Key Specifications
- تصنيف السلامة: بل ه / سيل 3 (في ايزو 13849-1 / اللجنة الانتخابية المستقلة 61508)
- مزود الطاقة: تيار مستمر 24 فولت
- المدخلات: 14 digital safety inputs
- النواتج: 4 semiconductor safety outputs (OSSD)
- تواصل: The base unit has an integrated Ethernet port. Programming is supported via the PNOZmulti Configurator software; expansion modules can be connected.
- وظائف: Graphical configuration of safety logic for E-stop, safety gates, safety light curtains, two-hand buttons, safety limit switches, إلخ.
- الضميمة: تركيب السكك الحديدية DIN, IP20, cabinet installation
- برمجة: مكون PNOZmulti (free configuration software, graphical drag-and-drop, no programming language required)
🧩 Product Positioning
The PNOZ m B0 (772138) is a compact modular safety PLC within the PNOZmulti family. It operates independently. When I/O capacity is insufficient, PNOZmulti expansion modules (على سبيل المثال. 772140, 772142) can be added to expand safety inputs and relay outputs.
🛠️ Typical Application Scenarios
أدوات الآلة, آلات التعبئة والتغليف, خطوط الإنتاج الآلي
Robot safety protection, safety gate interlocking
Emergency stop circuits, safety light curtain monitoring
Presses, conveyor safety control
⚠️ Critical Model Distinction (Common Confusion)
772138: PNOZ m B0 (semiconductor OSSD outputs, 4 OSSD channels)
772140: PNOZ m B1 (version with relay outputs)
📌 Configuration & التشخيص
PC Connection: Use USB/Ethernet to connect to a PC for program download and online diagnostics via PNOZmulti Configurator
Local Indication: Front-panel LEDs for fast diagnosis of input, output and fault status
🔍 Spare Parts & معلومات الاستبدال
Original direct replacement: Same part number 772138. Check the latest PILZ product obsolescence notice for end-of-life status.
Domestic equivalent reference: ابتكار, Xinje safety PLC, Schneider XPSM series. These are solution-level alternatives only, not direct hardware drop-in replacements. Safety logic must be reconfigured.
📎 Common Troubleshooting Checklist
- No LEDs after power-up: Check DC24V supply and polarity
- Flashing fault LED: Configuration validation error, wiring short-circuit, OSSD overload
- Safety circuit cannot be enabled: Check wiring of safety input channels, contact status of E-stop / safety gate, software configuration logic
- فشل الاتصالات: Inspect network cable, عنوان IP, software version compatibility
PNOZmulti Configurator Getting Started Example (PNOZ m B0 /772138)
Project Goal: Dual-channel E-stop + dual-channel safety gate, shared external reset button, meeting PL e / SIL3. Uses only onboard I/O of the base unit, no expansion modules.
برمجة: مكون PNOZmulti (free download from official website, graphical drag-and-drop configuration, no coding)
- Hardware Point Assignment (PNOZ m B0 Terminal Block)
| إشارة | Hardware Channel | وصف |
| Dual-channel E-stop (مغلقة عادة) | I0 / I1, test pulses T0 / T1 | يكتب 3 ثنائي القناة, cross-contact short-circuit detection |
| Dual-channel safety gate (PSEN mechanical safety gate, مغلقة عادة) | I2 / I3, test pulses T2 / T3 | يكتب 3 ثنائي القناة, cross-contact short-circuit detection |
| Manual reset button (مفتوحة عادة) | I4 | Reset signal, single-channel input |
| Safety semiconductor OSSD output | O0, O1 (paired OSSD) | Safety enable output, محركات المؤازرة / contactor safety circuit |
Wiring Note: E-stop and safety gate must use two independent normally closed contacts. The reset button is normally open. Manual reset is mandatory (per safety standards: manual confirmation required after fault clearance; automatic restart on power-up is prohibited).
- New Project Setup in Software
- Open Configurator → New project, hardware selection PNOZ m B0 (772138)
- Enter [تكوين الأجهزة]: No expansion modules for this project, confirm directly
- Enter [User Program] (graphical canvas, drag-and-drop function blocks)
ثالثا. يضيف & Configure Function Blocks
1) Add E-STOP Function Block
Drag E-STOP from the library onto the canvas
Input tab:
Switch type: Type3 (Dual-channel NC)
✅ Check Detect short-circuit between contacts (mandatory for dual-channel fault diagnosis)
Channel1: I0, test pulse T0; Channel2: I1, test pulse T1
Reset tab: إعادة الضبط اليدوي, reset input I4
اسم: E-STOP_Machine_EmergencyStop
2) Add Safety Gate Function Block
Drag the Safety Gate function block
Input tab:
يكتب: Type3 dual-channel normally closed
✅ Check detect short-circuit between contacts
Channel1: I2, T2; Channel2: I3, T3
Reset tab: إعادة الضبط اليدوي, reset input I4 (shared reset button with E-stop)
اسم: `SAFETY_GATE_ProtectionGate`
3) Add AND Logic Block
Logic rule: E-stop OK AND Safety gate closed → Safety output enable
Drag AND logic block
Two AND inputs: connect to OK output of E-STOP block and OK output of Safety Gate block respectively
AND output → connect to [Semiconductor Safety Output OSSD] function block
4) Add Semiconductor Safety Output OSSD
Drag OSSD output block, assign hardware O0, O1 (paired safety output)
مدخل: Output signal from AND block
Output feedback: Contactor feedback monitoring not implemented in this example; can be added later if required
Simplified logic description: E-stop released AND safety gate closed → press reset, OSSD safety output ON. If any safety condition is violated, OSSD cuts off immediately.
- Validation, تحميل & Online Diagnostics
- Click [Project Validation] to check CRC, parameters and hardware matching, resolve all errors
- Two download options:
الخيار أ: Micro USB cable directly connected to PNOZ m B0 for online program download
الخيار ب: Download to memory chip card, insert card into controller; program loads automatically on power-up
- Online diagnostic: Real-time monitoring of I0~I4 input status, OSSD output status and fault codes
- After download, set hardware to Run mode and perform field testing
- Field Test Logic (Verification)
- Normal condition: E-stop released, safety gate closed → press reset → OSSD output ON (safety enable)
- E-stop pressed: E-STOP block trips → AND output de-energized → OSSD OFF immediately
- Safety gate opened: Safety gate block trips → AND output de-energized → OSSD OFF immediately
- Fault recovery: After E-stop released / gate closed, reset button must be pressed again to re-enable safety output
- Common Configuration Pitfalls (High Priority)
- Type3 dual-channel: Two contacts must be independent, do not short internally, otherwise short-circuit detection triggers faults
- Test pulse T must correspond one-to-one with input I; channels cannot share test pulses
- Reset configuration: Machinery safety standards forbid automatic reset. Safety output cannot auto-restart after gate opening or E-stop activation
- OSSD is semiconductor output with short-circuit monitoring; short circuit on downstream load triggers safety fault
- Safety rating: This configuration achieves PL e / SIL3 only with correct wiring. Incorrect wiring downgrades safety level.
سابعا. خيارات التوسع (Modify within the same project later)
Add safety light curtain function block
Add contactor feedback monitoring (external feedback circuit)
Add OFF-Delay for inertial stopping
Add Modbus TCP/Profinet communication to transmit safety status to PLC
PILZ PNOZmulti 2 قائمة النماذج الكاملة (PNOZ m Series including 772138)
وصف: PNOZmulti 2 is the second-generation modular safety controller. Divided into Base Unit, I/O Expansion Modules EF, Fieldbus Communication Modules ES, Motion Monitoring Modules and Accessories. Your referenced 772138 = PNOZ m ES Profinet (Profinet communication module)
- Base Units (وحدة التحكم الرئيسية)
| رقم الجزء. | Model Name | Key Description |
| 772100 | PNOZ m B0 | General base unit, الأعلى 6 safety expansion modules; 20 safety inputs, 4 OSSD semiconductor outputs, USB + memory chip card |
| 772104 | PNOZ m B0.1 | Economy B0 version, الأعلى 1 I/O expansion module only; 20 safety inputs, 4 OSSD |
| 772101 | PNOZ m B1 | Large-scale project main unit, integrated Modbus TCP, dual Ethernet ports; الأعلى 12 safety expansion modules |
| 772102 | PNOZ m B1 Burner | B1 burner dedicated version with built-in burner safety function blocks |
| 772105 | PNOZ m C0 | Compact non-expandable standalone unit; 8 safety inputs, 4 OSSD, لا القدرة على التوسع, for small standalone machines |
- I/O Expansion Modules (PNOZ m EF series, right-side expansion)
| رقم الجزء. | Model Name | مواصفة |
| 772140 | PNOZ m EF 16DI | 16-channel safety digital input |
| 772142 | PNOZ m EF 8DI4DO | 8 safety DI + 4 safety semiconductor OSSD outputs |
| 772143 | PNOZ m EF 4DI4DOR | 4 safety DI + 4 safety relay outputs (relay contacts) |
| 772144 | PNOZ m EF 8DI2DOT | 8 safety DI + 2 bipolar semiconductor safety outputs (press machine dedicated) |
| 772145 | PNOZ m EF 2DOR | 2-channel safety relay output module (new compact relay module) |
| 772160 | PNOZ m EF 4AI | 4-المدخلات التناظرية لسلامة القناة (0-10V / 4-20أماه) |
| 772170 | PNOZ m EF 1MM | Single-axis safety motion monitoring (سرعة, standstill, اتجاه) |
| 772171 | PNOZ m EF 2MM | Dual-axis safety motion monitoring |
| 772120 | PNOZ m EF Multi Link | Safety interconnection between two PNOZmulti2 controllers |
| 772122 | PNOZ m EF SafetyNET | SafetyNET p real-time safety Ethernet interconnection module |
ثالثا. Fieldbus Communication Modules (PNOZ m ES, plug into left side of base unit, مشتمل 772138)
Bus modules communicate with upper PLC to read safety status and transmit control signals
| 772138 | PNOZ m ES Profinet | Profinet Industrial Ethernet (النموذج المستهدف الخاص بك) |
| 772134 | PNOZ m ES EtherCAT | إيثركات (FSoE safety protocol) |
| 772135 | PNOZ m ES EtherNet/IP | إيثرنت/IP |
| 772136 | PNOZ m ES Profibus | بروفيبوس موانئ دبي |
| 772137 | PNOZ m ES CANopen | يمكنفتح |
| 772131 | PNOZ m ES CC-Link | CC لينك |
| 772130 | PNOZ m ES Powerlink | Ethernet POWERLINK |
| 772123 | PNOZ m ES ETH | General Ethernet module (مودبوس تكب) |
- Remote Distributed I/O (PDP67, IP67 field-side modules, requires PDP-Link)
| رقم الجزء. | Model Name | مواصفة |
| 772600 | PDP67 F 8DI4DO | 8من + 4يفعل, تصنيف الحماية IP67 |
| 772610 | PDP67 F 10DI4DO | 10من + 4يفعل |
| 772121 | PNOZ m EF PDP Link | Controller-side coupler for PDP67 |
- Common Accessories List
| رقم الجزء. | اسم الملحق |
| 779261 | End cap (termination cover for module bus end) |
| 312992 | Mini USB download cable, 3م |
| 750008 | Screw terminal kit |
| 751008 | Spring-cage terminal kit |
Supplementary Key Notes
- Installation Position Differentiation
EF I/O modules: cascaded on the right side
ES bus communication modules: inserted on the left side of base unit, الأعلى 1 bus module per controller
- التوافق: B0/B0.1/B1/C0 all support ES bus modules. B0.1 supports only 1 EF I/O module; B0 max 6 EF modules, B1 max 12 EF modules
- مستوى الأمان: Proper configuration and wiring of the full system achieves maximum PL e / SIL3
- برمجة: All devices use PNOZmulti Configurator for unified configuration
Legacy PNOZmulti Classic (1st Generation, separate from PNOZmulti2)
Old generation mm0p/mm1p/mm2p/mm3p, part number series 7720xx. Hardware is incompatible with 2nd-gen B0/B1. Project migration requires full reconfiguration; hardware cannot be hot-swapped as direct replacement.
PNOZmulti 2 (PILZ 2nd-Gen Modular Safety Controller) سيناريوهات التطبيق
PNOZmulti2 core positioning: Programmable modular safety system up to PL e / SIL3. Used for stand-alone / multi-axis machine safety monitoring, replacing discrete safety relays. Supports safety logic configuration, fieldbus communication and safety motion monitoring. Applications grouped by industry and safety tasks as below.
- Machine Tool Industry (التطبيق الأكثر شيوعا)
- Metal-cutting machine tools (Machining centers, مخارط, المطاحن, آلات الطحن)
Guard door interlock, safety light curtain / laser scanner monitoring
Dual-channel E-stop, two-hand operation buttons
Axis safety monitoring: SSM Safe Speed Monitoring, SS1 Safe Stop 1, SLS Safely Limited Speed (paired with MM motion modules)
Safe stop for spindle / feed axes; axis lockout when guard door is open
Local safety diagnostics, safety status and fault codes uploaded via Profinet/EtherCAT to main PLC (772138 PNOZ m ES Profinet widely used)
- يضعط / الانحناء / آلات القص
Safety light curtain + two-hand button combination
Press cam monitoring, slide position monitoring
Anti-restart function, delayed safe stop for inertial hazard mitigation
نصيحة الاختيار: PNOZ m EF 8DI2DOT bipolar semiconductor output module is frequently selected.
- التعبئة والتغليف & Conveyor Automation
- ماكينات التعبئة والتغليف: Vertical form fill seal, pillow packaging, case packers, palletizers, stretch wrappers
Machine guard doors, safety light curtains, E-stop circuits
Safety zone monitoring for conveyor lines, area laser scanners
Conveyor safe stop, material jam safety interlock
- Complete production lines, فرز & أنظمة النقل
Multi-zone safety interlock: Opening door A stops only the corresponding zone instead of the whole line (zone safety is a major advantage of PNOZmulti2)
Distributed field I/O PDP67 for local sensor connection (IP67)
Safety status transmitted via fieldbus to main PLC / HMI for fault alarming
ثالثا. Robot Workcells (Industrial Robot Safety)
Robot perimeter guard doors, safety laser scanners
Safety zone switching: Automatic operation zone / reduced safe speed SLS for manual intervention
Dual-channel E-stop, safety reset logic
Combined safety interlock for robot + peripheral tooling (tool guard doors, clamp confirmation)
Safety signal exchange with robot controller; Profinet/EtherCAT transmits safety diagnostic data
- ممحاة & بلاستيك, Extrusion & Injection Molding Equipment
آلات صب الحقن: Mold safety doors, injection unit guards, safety light curtains
الطارد, خطوط التكوير: Barrel and die head guard interlocks
Roller, calender safety protection against entrapment hazards
Delayed safe stop for inertial rotating rollers
- التعامل مع المواد & أتمتة المستودعات
- Stacker cranes, automated warehouses, RGV/AGV workstations
Maintenance access doors, guardrail safety doors, أوقف
Travel axis safe speed limiting, safe standstill monitoring
Zone locking during maintenance for partial isolation
- Lifts, مصاعد, hoist auxiliary equipment (only surrounding safety control, not the hoisting mechanism itself)
Guard doors, safety limit monitoring to prevent personnel entering lifting zones
- طعام & المعدات الصيدلانية
ماكينات تعبئة, capping machines, labellers, cleaning equipment
Hygienic safety doors and safety sensors
Compliance with EN ISO13849 machinery safety standard; IP20 controller in electrical cabinet paired with IP67 PDP67 remote I/O for sensors installed on-machine for washdown environments.
سابعا. Tire, Paper & Textile Large Production Lines
Large roller equipment, winders, paper rewinding machines
Multi-axis coordinated safety monitoring (Dual-axis motion module EF 2MM)
Multiple E-stop buttons along long production lines, segmented safety isolation
Centralized management for many safety doors and light curtains on large machines
ثامنا. الصناعات الخاصة
- Combustion / heat-treatment equipment: PNOZ m B1 Burner dedicated base unit with built-in burner safety function blocks
- Test benches / trial equipment: Durability test rigs, impact test stands. Safety logic can be modified flexibly for product changeover without hardware replacement.
✅ Application Selection Guide (When to choose PNOZmulti2)
Recommended when:
Safety logic is not simple series connection of E-stop + safety gate, requiring AND/OR logic, timers, zone safety, conditional interlocks
High quantity of safety I/O, many safety gates, light curtains and E-stops to be centrally managed
Safety motion monitoring required (SLS/SSM/SS1 etc.)
Fieldbus communication needed (بروفينيت, إيثركات) to upload safety diagnostics to standard PLC (772138 Profinet module widely adopted)
Frequent product changeovers requiring safety logic modification without hardware swap
Inter-safety communication between multiple machines (Multi Link module for safe data exchange between two PNOZmulti2 controllers)
Not recommended (simple applications, discrete safety relays offer lower cost):
فقط 1 dual-channel E-stop, no other safety signals, simple logic
No fieldbus, no motion monitoring, minimal safety I/O
📌 Typical Configuration Example (772138 حل)
PNOZ m B0 (772100) + PNOZ m ES Profinet (772138) + EF I/O expansion modules
طلب: Robot workstation / machining center. Safety logic runs independently inside PNOZmulti2. Profinet transmits safety status and fault codes to Siemens S7 PLC / واجهة المستخدم البشرية.
🔎 Core Strengths Matching Application Highlights
- Graphical drag-and-drop configuration, simple safety logic modification
- Modular architecture: Base unit + I/O expansion + bus + motion modules assembled on demand
- Independent safety kernel: Safety logic runs autonomously, independent of upper PLC (core advantage of safety controllers. Protection remains valid even if main PLC fails.)
- Supports IP67 distributed remote I/O for large production lines
- Multi-axis safety motion monitoring, key selling point for machine tool and robot applications
- Rich fieldbus interfaces for seamless connection with mainstream PLC brands
المقاولين,قاطع الدائرة,الاستشعار,التشفير,بلك,محول






















NH42-63-318x560.png)