The LC1G800KUEN is a 3-pole high-power contactor of Schneider Electric TeSys Giga Global Standard Version. It is the official successor to the high-current contactors of the original TeSys F series. It is mainly used for direct start and stop control of three-phase asynchronous motors, as well as switching control of high-capacity inductive and resistive loads. ...

  • تفاصيل المنتج

The LC1G800KUEN is a 3-pole high-power contactor ل شنايدر إلكتريك TeSys Giga Global Standard Version. It is the official successor to the high-current contactors of the original TeSys F series. It is mainly used for direct start and stop control of three-phase asynchronous motors, as well as switching control of high-capacity inductive and resistive loads.

This model adopts a wide-range AC/DC universal electronic coil, and comes standard with contact wear self-diagnosis and coil over/undervoltage monitoring functions to support predictive maintenance. Featuring compact size, قدرة كسر عالية, long mechanical and electrical service life, it is widely applied in heavy-duty industrial sectors including metallurgy, التعدين, معالجة المياه, التدفئة والتهوية وتكييف الهواء, photovoltaic and energy storage.

  1. انهيار رمز النموذج

النموذج الكامل: LC1G800KUEN

  1. LC1: Basic product type, standard single-unit 3-pole contactor for AC loads on main circuits.
  2. ز: رمز السلسلة, TeSys Giga high-power contactor series.
  3. 800: Rated current rating. Rated operational current is 800A under utilization category AC-3 at 440V. 3-pole configuration (A digit “4” is added after the current rating for 4-pole models, على سبيل المثال. LC1G8004KUEN).
  4. KU: Coil specification code, stands for 100~250V AC/DC wide-range low-power electronic coil.
  5. في: Version code, Global Standard Version (international general version; domestically manufactured models are suffixed with “ج”, على سبيل المثال. LC1G800KUEC).
  6. المعلمات التقنية الأساسية

3.1 معلمات الدائرة الرئيسية

غرضمواصفة
البولنديين & تكوين الاتصال3ص, 3 Normally Open main contacts
Conventional Thermal Current (إيث)1050أ (Ambient temperature ≤ 40℃)
تصنيف التشغيل الحالي (ايه سي-1)1050أ (≤1000V AC, ≤40℃); 800أ (≥60 درجة مئوية)
تصنيف التشغيل الحالي (ايه سي-3)800أ (≤440V AC, ≥60 درجة مئوية)
Maximum Rated Operational Voltage (إي)1000الخامس و
Rated Control Power (ايه سي-3)400V: 450كيلوواط; 690V: 800كيلوواط; 1000V: 1000كيلوواط
قدرة الكسر المقدرة (AC-3 @ 440V)5870أ
تصنيف وقت قصير الصمود الحالي (اي سي دبليو)5.5ال / 10ق
الدافع المقدر لتحمل الجهد (امب)8كيلو فولت
Overvoltage CategoryCategory III
Rated Power Consumption per Pole (ايه سي-3)130دبليو
اتصال الدائرة الرئيسيةFront bolt connection, terminal spacing: 70مم

3.2 معلمات دائرة التحكم

غرضمواصفة
Coil Voltage Range (جامعة كاليفورنيا)100~250V AC 50/60Hz; 100~250V DC
Normal Pick-up Voltage Range0.8Uc ~ 1.1Uc (Ambient temperature ≤ 60℃)
Drop-out Voltage Range0.1Uc ~ 0.45Uc (Ambient temperature ≤ 60℃)
Undervoltage Alarm Threshold<80V (Below 80% of the minimum rated voltage)
Overvoltage Alarm Threshold>275V (Above 110% of the maximum rated voltage)
نوع الملفLow-power wide-range electronic coil, التيار المتناوب/تيار مستمر عالمي
Standard Auxiliary Contacts1لا + 1نورث كارولاينا, compatible with 17V/1mA low-level PLC signals
اتصال دائرة التحكمPush-in terminals

3.3 ميكانيكية & المعلمات البيئية

غرضمواصفة
الأبعاد الشاملة (H × W × D)284mm × 211mm × 266mm
الوزن الصافيتقريبا. 14.2كجم
فئة الحمايةIP20 on front side; optional terminal shroud for enhanced protection
Operating Ambient Temperature-25درجه مئوية ~ +60 درجه مئوية (No current derating within 60℃); الأعلى. 70درجه مئوية (Current derating required)
Installation AltitudeNo current derating up to 3000m
طريقة التركيبVertical bolt mounting, available for vertical installation in three quadrants
الشهاداتاللجنة الانتخابية المستقلة 60947-4-1, م, أول, وكالة الفضاء الكندية, سي سي سي, UKCA

3.4 خدمة الحياة & معلمات الأداء

غرضمواصفة
الحياة الميكانيكية5,000,000 دورات التشغيل
الحياة الكهربائية (ايه سي-3)800,000 دورات التشغيل
الحد الأقصى لتردد التشغيل500 دورات في الساعة
Standard Diagnostic FunctionsContact wear monitoring, coil over/undervoltage monitoring, control module self-diagnosis
  1. نماذج بديلة & Cross-series Comparison

4.1 Same-brand Alternatives

  1. Replacement for Discontinued Models: Direct replacement for legacy TeSys F series LC1F780 and LC1F800. It is the official upgraded version with overall improved electrical performance. Installation hole positions require adaptation.
  2. Same Current Rating with Different Coils:

LC1G800EHEN: 48~130V AC/DC wide-range coil

LC1G800LSEN: 200~500V AC/DC wide-range coil

  1. 4-pole Version of Same Rating: LC1G8004KUEN (4-القطب, rated 1050A under AC-1)
  2. Domestic Version: LC1G800KUEC (Manufactured domestically with identical parameters, suitable for local supply chains and certifications)

4.2 Equivalent Products of Other Brands

ايه بي بي: AF750-30-11 series contactor

سيمنز: 3RT1276 series contactor

شينت: NXC-800 series contactor

> ملحوظة: Verify installation dimensions and terminal spacing for cross-brand replacement. Direct drop-in replacement is not recommended.

  1. Full List of TeSys Giga Global 3-pole Contactors (KU Coil)
نموذجالتصنيف الحالي (AC-3 @ 440V)Corresponding Motor Power @ 400V
LC1G115KUEN115أ55كيلوواط
LC1G150KUEN150أ75كيلوواط
LC1G185KUEN185أ90كيلوواط
LC1G225KUEN225أ110كيلوواط
LC1G265KUEN265أ132كيلوواط
LC1G330KUEN330أ160كيلوواط
LC1G400KUEN400أ200كيلوواط
LC1G500KUEN500أ250كيلوواط
LC1G630KUEN630أ335كيلوواط
LC1G800KUEN800أ450كيلوواط

Common Accessories

مرحل الحمل الزائد الحراري: LR9G series (على سبيل المثال. LR9G800), direct bottom mounting available

توسيع الاتصال المساعد: LAG8N113P (1لا + 1NC), LAG8N203P (2لا)

وحدة التعشيق الميكانيكية: LA9G970

Remote Wear Diagnostic Module: LA9GRD01 / LA9GRD10

Terminal Extension Kit: LA9G3102

  1. نطاق التطبيق & Environmental Limits

6.1 التطبيقات النموذجية

  1. التحكم في المحركات: Direct start/stop of three-phase asynchronous motors for high-power fans, مضخات المياه, الضواغط, conveyor lines and hoisting equipment.
  2. نظام توزيع الطاقة: Switching of high-capacity feeder circuits and switching of reactive power compensation capacitor banks (capacitor-specific version required).
  3. صناعة الطاقة الجديدة: Main circuits of high-power combiner cabinets in photovoltaic & energy storage power stations, front switches of PCS converters.
  4. Heavy-duty Industry: Control of high-capacity loads in metallurgy, التعدين, معالجة المياه, data centers and other industries.

6.2 المتطلبات البيئية

For indoor installation inside switchgears only; outdoor exposed use is prohibited.

Pollution level: No higher than Class 3; no corrosive, explosive gas or conductive dust.

No severe vibration on mounting surface; vibration acceleration ≤ 10m/s².

Current derating is required if installation altitude exceeds 3000m or ambient temperature exceeds 60℃, refer to official manual for calculation.

  1. Troubleshooting Matrix
ظاهرة الخللالسبب الجذريStep-by-step Solutions
Contactor fails to pull in with no sound1. No power supply to control circuit or loose wiring1. Cut off power and verify safety; check wiring at terminals A1/A2 and re-measure control voltage
2. Broken or burnt coil2. Test coil resistance with multimeter; replace coil if open circuit is detected
3. Mechanical jamming of armature3. Manually press armature after power-off, clean oil and dust on core pole faces
4. Supply voltage far below rated range4. Adjust power supply to rated range: 100~250V
Repeated tripping after pull-in; indicator flashes twiceCoil undervoltage; continuous supply below 80V1. Measure real-time coil voltage, check cable voltage drop and contact resistance of upstream contacts
2. Use larger gauge wires for control circuit and verify power capacity
Abnormal coil overheating; indicator flashes three timesCoil overvoltage; continuous supply above 275V1. Verify supply voltage level and eliminate wrong wiring to higher voltage
2. Replace with 200~500V wide-range coil (LSE type)
Over 85℃ temperature rise at main terminals / اتصالات1. Loose wiring and excessive contact resistance1. Retighten connection bolts according to torque specifications after power-off
2. Long-term load overload2. قياس الحمل الحالي, verify model selection and upgrade rating if necessary
3. Poor contact due to contact ablation3. Polish slightly ablated contacts; replace contact module for severe damage
Indicator flashes once; contact wear alarmMain contacts approaching end of electrical life; wear reaches warning threshold1. Read remaining service life via diagnostic function and prepare spare parts in advance
2. Shut down equipment and replace main contact module to avoid contact welding
Abnormal auxiliary contact signal; no feedback to PLC1. Loose or ablated auxiliary contact module1. Check module installation and test on-off status after power-off
2. Wrong wiring or broken cable2. استبدال وحدة الاتصال المساعدة, recheck wiring and PLC input circuit
Indicator flashes continuouslyInternal hardware or software fault of control module1. Power cycle the contactor and check recovery
2. Replace electronic control module or complete unit if fault recurs

> Schneider official flashing code rule: 0.5s per cycle. Flash times correspond to different faults. Continuous flashing indicates internal failure of the control module.

The LC1G800KUEN is an 800A 3-pole high-power contactor from Schneider TeSys Giga series, designed for switching heavy-duty and high-reliability high-power loads, suitable for AC-3 motor loads and AC-1 resistive/distribution loads. Equipped with wide-range AC/DC coil, contact wear self-diagnosis, full-load operation at -25℃~60℃ and 500 operating cycles per hour, it is categorized into five major application fields as below:

  1. Direct Start & Stop of High-power Motors in Heavy Industry

As its core application, the 800A rated current under AC-3 corresponds to 450kW three-phase asynchronous motor at 400V and 800kW at 690V, ideal for industrial equipment with heavy starting load and continuous operation:

  1. علم المعادن & التعدين: Large ball mills, jaw crushers, main exhaust fans for sintering plants, mine hoists and main motors of long-distance belt conveyors. Its wide temperature tolerance, high shock resistance and contact wear diagnosis effectively reduce unplanned downtime for dusty and high-temperature working conditions.
  2. صناعة البتروكيماويات: Process compressors, high-pressure circulating pumps, large agitator motors for reaction kettles and raw material delivery pumps. The wide-range coil adapts to grid voltage fluctuation in factories; low power consumption cuts operating costs; PLC remote control ensures high reliability for continuous production.
  3. Cement & Building Materials: Main drive motors for rotary kilns, raw/cement mill main units and high-temperature kiln exhaust fans. Stable performance at 60℃ suits high-temperature areas around kilns, and long electrical life fits frequent start-stop operation.
  4. High-capacity Pump & Valve Systems for Municipal & معالجة المياه

Its high reliability and diagnostic functions meet the requirements of unattended and long-term continuous operation for large pumps in municipal and water conservancy projects:

  1. Municipal Water Supply & Drainage: Main water pumps of large water intake and booster pumping stations (single motor power: 200~450kW), aeration blowers, sludge return pumps and main units of intake pump houses in sewage treatment plants. Wide-range coil copes with municipal grid fluctuation; contact wear warning realizes predictive maintenance and reduces manual inspection.
  2. Water Conservancy & Flood Control: Main unit control for large drainage pumping stations and inter-basin water transfer projects. High breaking capacity and long mechanical life guarantee reliable operation under emergency flood control conditions.
  3. Switching of High-capacity Circuits in Low-voltage Distribution Systems

With 1050A conventional thermal current under AC-1, this contactor acts as a high-capacity distribution switch for remote automatic control:

  1. Industrial Low-voltage Distribution: Remote switching of low-voltage bus couplers and large-capacity feeders in workshops to realize distribution automation; also used for main incoming power switching of large production lines for remote start/stop of the whole line.
  2. Reactive Power Compensation & إدارة جودة الطاقة: Switching of large-capacity low-voltage capacitor banks (capacitor-specific contact module or current-limiting reactor required) for low-voltage reactive power compensation cabinets in steel plants, mines and data centers to dynamically adjust power factor.
  3. Critical Power Switching: UPS bypass circuits and diesel generator incoming switching in data centers and industrial control rooms. The AC/DC universal coil adapts to emergency power voltage fluctuation and ensures power continuity.
  4. High-power Circuit Control for New Energy & تخزين الطاقة

It satisfies wide temperature range, high current and AC/DC compatibility requirements of new energy applications:

  1. Photovoltaic & Energy Storage Power Stations: Main circuits of centralized PV combiner cabinets, front AC main switches of energy storage PCS converters and general circuits of battery clusters. It supports cold start at -25℃ for outdoor stations in northern regions, and the wide-range coil is compatible with DC control power and AC auxiliary power on site.
  2. High-power Charging Facilities: Main incoming control of charging clusters for EV ultra-fast charging stations and power circuit switching of split charging stacks, capable of frequent switching under high current.
  3. Other Special Heavy-duty Applications
  4. Hoisting & Port Machinery: Main hoist and travelling motors of port portal cranes and large overhead travelling cranes. 500 cycles per hour matches frequent start-stop of hoisting work; mechanical interlock accessories enable safe control of forward/reverse rotation circuits.
  5. Large Industrial HVAC: Main compressors of centrifugal chillers, cooling water pumps and cooling tower fans in super-large commercial complexes, data centers and industrial plants, meeting start-stop and protection demands of high-power HVAC units.
  6. Marine & Shore Power Systems: Low-voltage main distribution circuits on ships and shore power connection switches at ports. Wide voltage range adapts to different shore power standards, and wide temperature design fits cabin and outdoor port environments.

Application Selection Tips

For special applications such as capacitor switching and DC loads, verify dedicated contacts and breaking capacity; standard motor-type contactor shall not be used directly.

Conduct current derating calculation in accordance with the manual if ambient temperature exceeds 60℃ or installation altitude exceeds 3000m.