شرح كود النموذج (XB2-BVM4LC) Model Segment Definition XB2 Harmony XB2 Series – 22mm Standard Pushbutton & Pilot Light Range B Integrated complete pilot light (head and base as one unit, no assembly required) V Pilot Light M LED light source, AC 220~230V 50/60Hz AC version 4 Light head color: Red LC Factory version complying with Chinese ...

  • تفاصيل المنتج

شرح كود النموذج (XB2-BVM4LC)

الجزء النموذجيتعريف
XB2Harmony XB2 Series – 22mm Standard Pushbutton & Pilot Light Range
بIntegrated complete pilot light (head and base as one unit, no assembly required)
VPilot Light
ممصدر ضوء LED, AC 220~230V 50/60Hz AC version
4Light head color: أحمر
إل سيFactory version complying with Chinese standards, plastic threaded mounting base

Supplementary color codes for the same series:

1 = White, 3 = Green, 4 = Red, 5 = Yellow, 6 = Blue

Suffixes for voltage differentiation:

م: تيار متردد 220 فولت

س: تيار متردد 380 فولت

ب: AC/DC 24V

د: DC direct current

  1. المواصفات الفنية الأساسية

2.1 التقييمات الكهربائية

الجهد المقنن: AC 220~230V, 50/60هرتز

Allowable Voltage Fluctuation: 0.8~1.1×Us (176V~253V)

التشغيل الحالي: تقريبا. 20أماه

مصدر الضوء: High-brightness monochromatic LED, filament-free, عمر خدمة طويل

Overvoltage Category: Class I

2.2 Mechanical Mounting Dimensions

انقطاع اللوحة: Standard Φ22.5mm

طريقة التركيب: Secured via rotating plastic lock nut; compatible with control cabinet panels of 1~6mm thickness

Head Appearance: Round convex lens cover

2.3 حماية & المواصفات البيئية

حماية الدخول: IP66 (front dustproof and waterproof); IK05 impact resistance

درجة حرارة التشغيل: -25درجه مئوية ~ +55 درجه مئوية

درجة حرارة التخزين: -40درجه مئوية ~ +70 درجه مئوية

Applicable Altitude: ≥2000 م, no power derating required

معايير الامتثال: IEC60947-5-1, جيجابايت/T14048.5, م, بنفايات, يصل

2.4 Service Life Metrics

LED Electrical Service Life: ≥50,000 hours of continuous illumination

مقاومة الاهتزاز: 15ز (40~2000Hz)

  1. بناء & تعليمات الأسلاك

3.1 Terminal Definition

The base is equipped with only 2 wiring terminals X1 and X2, non-polarized for AC supply

X1: Live wire L

X2: Neutral wire N

AC circuits have no polarity; connecting the two terminals to any position of a 220V circuit will light up the red pilot light.

3.2 إجراءات التركيب

  1. Drill a Φ22.5mm round hole on the control cabinet panel, insert the pilot light body from the front side of the panel;
  2. Fit the lock nut onto the rear side and tighten manually for fixation;
  3. Connect control wires to terminals X1 and X2 on the base, then fasten wire clamping screws;
  4. Switch on power to test steady illumination.
  5. سيناريوهات التطبيق
  6. Standard application for red lights: Equipment fault alarm, emergency stop circuit indication, overload warning, shutdown alert;
  7. Compatible equipment: خزائن التحكم PLC, ضواغط الهواء, أدوات الآلة, production lines, water pump & fan control boxes;
  8. نوع الدائرة: Mains AC 220V control circuit, no intermediate transformer required.
  9. Cross-Series Selection Reference Table
نموذجلونالجهد المقننسيناريو التطبيق
XB2-BVM1LCأبيضتيار متردد 220 فولتStandby, power-on indication
XB2-BVM3LCأخضرتيار متردد 220 فولتNormal equipment running status
XB2-BVM4LCأحمرتيار متردد 220 فولتFault, shutdown, إنذار
XB2-BVM5LCأصفرتيار متردد 220 فولتReady state, pre-alert warning
XB2-BVM6LCأزرقتيار متردد 220 فولتManual/Auto mode differentiation

24V low-voltage alternative model: XB2-BVB4LC (أحمر, 24الخامس التيار المتناوب/تيار مستمر)

  1. Troubleshooting Matrix
ظاهرة الخللالسبب الجذريحل
No illumination after power-on1. No 220V supply in circuit; 2. Loose wire terminals; 3. Burnt LED chipMeasure circuit voltage with multimeter; retighten wiring terminals; replace the complete pilot light assembly
Flickering light with unstable brightnessVoltage exceeds 0.8~1.1 times rated value, اتصال سلكي سيئStabilize supply voltage; re-crimp connecting wires
Severe overheating of pilot lightLong-term overvoltage operation, circuit leakageVerify input voltage; inspect circuit insulation integrity
Internal short circuit caused by water ingress into panelLoose lock nut, oversized panel cutout damaging IP66 performanceTighten lock nut fully, seal gaps on panel cutout
  1. مواصفات التشغيل الآمن
  2. Strictly prohibit direct connection to 380V supply, which will burn out the LED instantly; select XB2-BVQ4LC for 380V circuits;
  3. Recommended wire: 0.75~1.5mm² solid copper wire;
  4. Install cabinet sealing gaskets for humid control cabinets and outdoor enclosures to maintain IP66 protection;
  5. Designed solely for status indication, unable to carry high-power loads; no contact output function;
  6. Do not strike or grind the lens cover; scratches will drastically reduce light transmittance and protection performance.
  7. Order & Packaging Information

Individually packed per unit; standard packaging: 5 pieces per small box, 100 pieces per carton

Spare Parts: No separate LED chip spares available; replace the complete pilot light assembly if damaged

Conclusion on Color Replacement for شنايدر XB2-BVM4LC (XB2BVM4LC)

  1. Official Factory Conclusion: The lens cover and LED color cannot be replaced separately
  2. The XB2-BVM series adopts an integrated non-detachable sealed structure (lens cover, colored LED chip, 220V current-limiting circuit and base housing are integrally injection-molded).
  3. Schneider official FAQ clearly states: The internal LED module of integrated XB2 pilot lights cannot be disassembled separately, and colored lens covers or LED components are not sold as separate spare parts. Only illuminated pushbuttons with split bases support LED core replacement; this all-in-one light does not allow color component replacement.
  4. Illumination principle: The lens cover itself is transparent, with a built-in red LED chip (color is not generated via colored filter lenses). Even if the lens cover is forcibly unscrewed, the internal light source remains red and color modification is impossible.
  5. Two On-Site Color Modification Solutions

حل 1: Direct Full Unit Replacement (مُستَحسَن, Compliant, Factory Standard)

Purchase complete units of target color with the same AC 220V voltage; no wiring modification required, compatible with standard panel cutouts:

أبيض: XB2-BVM1LC

أخضر: XB2-BVM3LC

أصفر: XB2-BVM5LC

أزرق: XB2-BVM6LC

خطوات الاستبدال: Cut off power → Loosen rear lock nut on panel → Remove old red light → Install new colored pilot light → Tighten lock nut and restore wiring.

حل 2: Temporary Emergency Fix (Only for short-term maintenance, not recommended for long-term equipment operation)

  1. External colored film: Attach high-temperature resistant translucent colored film to lens surface. Drawbacks: Reduced light transmittance, accelerated aging due to heat, degraded IP protection rating;
  2. Translucent colored spray coating inside lens cover: Permanently destroys factory IP66 protection rating; water vapor ingress easily triggers short circuits and fails equipment acceptance standards.
  3. Distinction Between Two Easily Confused Products (To Avoid Wrong Selection)
  4. XB2-BVM Integrated Pilot Light (This Model): Non-replaceable color, integrated encapsulation, no separate LED core spares;
  5. XB4 Series Pilot Light / XB2 Split Illuminated Pushbutton: Modular design with separately replaceable LED heads for free color switching, suitable for cabinets requiring frequent color adjustments.
  6. ملاحظات تكميلية
  7. Mandatory voltage matching: The original XB2-BVM4LC is rated AC 220V; only models with suffix M (220V) are acceptable for replacement. Models with suffix B (24V) or Q (380V) cannot be used;
  8. Safety standards compliance: Red/Green/Yellow pilot lights on industrial equipment correspond to fault/Running/pre-alarm status. Unauthorized long-term color modification via film violates machine tool and power distribution safety standards and will fail acceptance inspection;
  9. شراء قطع الغيار: No separate lens or LED spares; only complete pilot light assemblies can be ordered as replacements.

السابق:

ترك الرد

ترك رسالة