Basic Identification & فك تشفير النموذج
التعيين الكامل: SIMATIC ET 200SP IM 155-6 PN/2 HF
6ES7: S7 Distributed I/O Series
155: ET200SP PROFINET Interface Module
6AU01: 2nd-generation 2-port High-Feature (التردد العالي) hardware version
0CN0: التردد العالي (High Feature) functional variant
تحديد المواقع: Head module for ET200SP remote stations, enabling remote I/O expansion via PROFINET for S7-1500 CPUs (1511ج / 1513ج / 1515 / 1517)
- Core Hardware Specifications
2.1 الأبعاد المادية & مزود الطاقة
| غرض | المعلمة |
| الأبعاد الشاملة | دبليو 15 mm × H 117 mm × D 74 مم |
| وزن | تقريبا. 120 ز (excluding BusAdapter) |
| تصاعد | معيار 35 مم DIN السكك الحديدية, IP20 (cabinet installation only) |
| مزود الطاقة | 24 V DC SELV/PELV, with integrated terminal blocks |
| العزل الكهربائي | 1500 V AC isolation between PROFINET ports and backplane bus |
| درجة الحرارة المحيطة | عملية: -25 °C ~ +60 درجة مئوية; Storage/Transport: -40 °C ~ +85 درجة مئوية |
2.2 I/O Expansion Capacity
Local backplane: حتى 64 ET200SP signal modules (fully compatible with digital, analog, عداد, positioning and safety modules)
Remote extension: حتى 16 ET200AL remote terminal modules
Hot swapping support: I/O modules can be replaced during operation without interrupting station-wide communication
Maximum backplane single-slot load: 1 أ / 24 في العاصمة (in conjunction with PM-E power terminals)
2.3 PROFINET Communication Capabilities (Core HF High-Feature Functions)
- Integrated 2-port switch; BusAdapter is a separately ordered accessory (not included with the base unit)
Optional BusAdapter types: 2×RJ45, 2×M12, 2×FC quick connectors, LC/SCRJ fiber optic, إلخ.
- Transmission Rate: 100 Mbps full-duplex, auto-crossing and auto-negotiation
- Full coverage of real-time protocols:
PROFINET RT (Standard Real-Time)
IRT Isochronous Real-Time: Minimum cycle of 31.25 ميكروس, dedicated for multi-axis motion synchronization
MRP Media Redundancy Protocol (ring self-recovery < 200 ms upon cable breakage)
S2 System Redundancy (dual CPU hot standby for industrial high availability)
Shared Device, PROFIenergy power management, priority startup
- Maximum PN connections: 16 I/O controllers / HMI hosts
2.4 Front Panel Status LEDs
PWR (أخضر): 24 V power supply normal
يجري (أخضر): Module operating correctly
ERROR (أحمر): Fault indication (تواصل / backplane / ماس كهربائى)
MAINT (أصفر): Maintenance reminder, diagnostic alarm
BusAdapter fitted with dual LINK/ACT port status LEDs
- Exclusive Advantages of HF High-Feature Version (vs Standard ST Model 6AU01-0BN0)
- Supports IRT isochronous synchronization and S2 system redundancy (unavailable on standard variant)
- Complete cable diagnostics, port packet loss statistics, granular channel-level diagnostics
- Larger backplane address space, compatible with more special function modules (high-speed counters, position input, safety F-modules)
- Multi-controller Shared Device, priority startup, precision clock forwarding for motion control
- Enhanced anti-interference and surge protection, ideal for high-reliability production lines in automotive, lithium battery and pharmaceutical industries
- Mandatory Matching Accessories (Separate Ordering Required)
- BusAdapter (mandatory; network cables cannot be connected without this adapter)
- ET200SP Server Terminal Module (installed at the far right end of the station, رقم الجزء. 6ES7193-6PA00-0AA0, required to terminate the backplane bus)
- Various signal base units, PM-E power terminals, digital/analog/counter/safety I/O modules
- 24 V power terminal plug (supplied as standard with the module)
- توافق البرامج
برامج البرمجة: TIA Portal V15.1 or higher
Compatible CPUs: Full S7-1500 series, ET200SP Open Controllers
GSDML Version: V2.34, interoperable with third-party PROFINET masters
- سيناريوهات التطبيق النموذجية
- Automobile Complete Vehicle & Component Production Lines: Multi-axis synchronized welding, conveyor lines relying on IRT isochronous synchronization
- بطارية الليثيوم & PV Equipment: MRP redundant ring networks, high-availability demand with S2 dual hot standby CPUs
- التعبئة والتغليف & Injection Molding Machine Tools: Remote expansion of high-speed pulse counter and positioning modules
- الصيدلانية & Food Processing Lines: Online hot-swap I/O replacement to minimize downtime
- Distributed Remote I/O Cabinets for Large Production Lines: حتى 64 modules per station to save cabinet installation space
- Same Series Model Comparison (Selection Differentiation)
| رقم الجزء | إصدار | Dual Ports | IRT | S2 Redundancy | MRP | السيناريوهات القابلة للتطبيق |
| 6ES7155-6AU01-0CN0 | HF High-Feature | √ | √ | √ | √ | التحكم في الحركة, التكرار, high-speed synchronization |
| 6ES7155-6AU01-0BN0 | ST Standard | √ | × | × | √ | General digital/analog I/O without synchronization requirements |
| 6ES7155-6AA01-0BN0 | Legacy Gen.1 ST | √ | × | × | √ | Replacement for outdated projects; lower performance than 6AU01 series |
- تثبيت & التكليف النقاط الرئيسية
- Installation Sequence: DIN rail → IM155-6PN HF base unit → sequential mounting of I/O base modules → server terminal module at the far right end
- Insert BusAdapter into the upper slot of the module and fasten the locking clip; shield grounding for both ends of network cables
- IRT Synchronization Applications: Enable isochronous synchronization on the CPU; synchronization domain cycle must match 31.25 / 62.5 / 125 / 250 ميكروس
- Redundant Ring Network: Activate MRP across the whole line for automatic switchover at ring breakpoints
- استكشاف الأخطاء وإصلاحها: Steady red ERROR light → backplane short circuit / missing terminal module; flashing red ERROR light → PROFINET disconnection / IP address conflict
- Selection Pitfalls to Avoid
- 0CN0 HF variant is mandatory for motion control, multi-axis synchronization and dual CPU hot standby; the standard 0BN0 model does not support IRT or S2 redundancy
- BusAdapter must be ordered separately; network port connectors are not pre-fitted to the base unit
- Missing server terminal module at the station end triggers backplane faults and steady red ERROR LED
- Derated operation is required at ambient temperatures above +60 درجة مئوية; reduce the quantity of backplane I/O modules
- Incompatible with ET200MP interface modules (IM155-5); backplane base units cannot be interchanged
Six Practical Field Application Cases of 6ES7155-6AU01-0CN0 (IM155-6 PN/2 HF)
Exclusive core capabilities of this module: IRT isochronous synchronization, S2 system redundancy, MRP ring network, runtime hot swapping, الحد الأقصى 64 وحدات الإدخال/الإخراج, expansion via up to 16 ET200AL units. All below cases select this HF model for its high-performance features, which cannot be fulfilled by the standard 6AU01-0BN0 variant.
قضية 1: Multi-Robot Synchronized Production Line in Automotive Welding Workshop (Core IRT Application)
نظرة عامة على المشروع
Main body welding line of a domestic vehicle OEM, controlled by S7-1517T motion CPU. The full line contains 12 remote I/O cabinets, each equipped with one 6ES7155-6AU01-0CN0. Every station carries 48 ET200SP I/O modules (الإدخال/الإخراج الرقمي, safety F-modules, encoder acquisition), realizing synchronized control with multiple S120 servo drives, KUKA robots and vision cameras.
شبكة & Functional Design
- BA 2×RJ45 BusAdapters adopted; full line configured as an IRT isochronous synchronization domain with a minimum cycle of 62.5 ميكروس.
- Shared system clock for multi-robot welding trajectories, conveyor servos and vision positioning, synchronization error < 1 ميكروس.
- Linear topology formed by cascading dual ports of each station; local segments built as MRP media redundant rings, with automatic self-recovery within 200 ms upon cable breakage without line shutdown.
- Supports Shared Device: I/O signals of one station can be read and written simultaneously by the main PLC controller and robot controllers.
Reason for Selecting HF (0CN0) نموذج
The standard variant lacks IRT function, leading to excessive jitter in multi-axis synchronization and welding offset defects. The HF model delivers precise clock forwarding to meet high-precision automotive welding process standards.
On-Site Benefits
Full-line control cycle reduced from 18 ms to 7 آنسة, welding reject rate cut by 65%. Faulty I/O modules can be hot-swapped online, cutting single workstation maintenance downtime by 80%.
قضية 2: Lithium Battery Stacking Equipment (S7-1500R/H S2 System Redundancy)
نظرة عامة على المشروع
Fully automatic stacking machine for new energy power batteries with customer requirement of zero downtime continuous production. Main control adopts S7-1515R redundant CPU; all four remote ET200SP stations deploy 6ES7155-6AU01-0CN0 to collect analog signals of pole piece positioning, correction servos, vacuum suction cups, درجة الحرارة والضغط.
Redundant Architecture Design
- S2 System Redundancy (multi-assigned I/O) enabled on each IM155-6 PN HF; two network cables connect to primary and standby redundant CPUs respectively.
- Seamless takeover of all remote I/O by standby PLC the instant the primary PLC fails, with no signal loss or equipment alarm/shutdown.
- MRP ring redundancy ensures production continuity despite single-point failures of cables or switches.
- 64-slot backplane expansion integrates high-speed counter modules to acquire encoder signals from stacking servos.
Key Selection Consideration
The standard 0BN0 model does not support S2 redundancy. Lithium production lines suffer massive scrapping losses once halted, making the HF version compulsory.
قضية 3: Aseptic Filling Line for Pharmaceutical Products (Hot Swap + Granular Diagnostics)
نظرة عامة على المشروع
Aseptic oral liquid filling line with distributed multi-station I/O, clean environment and frequent format changeovers; full-line shutdown for maintenance is prohibited. The main station uses S7-1511F safety PLC, مع 8 ET200SP remote stations fitted with 6ES7155-6AU01-0CN0 paired with safety F-DI/F-DO modules to comply with GMP safety regulations.
Unique HF Field Functions Implemented
- Full-module runtime hot swap: Faulty valve or sensor I/O modules at filling stations can be directly replaced while the PLC remains running without production stop.
- Granular channel diagnostics: Precise location of single-channel sensor open circuits or short circuits, with pop-up fault point alerts on HMI.
- PROFIenergy power saving function automatically cuts backplane I/O power during station standby to reduce energy consumption in clean rooms.
- Wide temperature operation range of -25 °C ~ +60 درجة مئوية, suitable for high-temperature control cabinets adjacent to sterilization ovens.
Disadvantages of Standard Variant for Comparison
0BN0 lacks complete channel-level diagnostics, limiting fault localization to the entire station and causing multi-hour troubleshooting delays; fine-grained energy management is unsupported.
قضية 4: High-Speed Full-Servo Packaging & Printing Production Line (Short-Cycle Motion Control)
نظرة عامة على المشروع
High-speed gravure printing machine for flexible food packaging with 12 servo axes for register control and a maximum printing speed of 300 م/دقيقة. Remote I/O cabinets distributed at unwinding, الطباعة, slitting and rewinding stations all adopt IM155-6 PN HF 6ES7155-6AU01-0CN0, paired with S7-1516T CPU.
Core Application Advantages
- IRT isochronous synchronization delivers accurate multi-color register alignment and eliminates printing ghosting defects.
- Linear cascading wiring via dual ports reduces the quantity of industrial switches and lowers total cost.
- Supports extension of up to 16 ET200AL remote terminals close to printing machine rollers, shortening sensor cable runs.
- High real-time bus achieves lag-free acquisition of encoder pulse signals, with no register offset during high-speed start-stop cycles.
قضية 5: MRP Redundant Ring Network for Large Automated Warehouse Logistics
نظرة عامة على المشروع
E-commerce automated high-bay warehouse with 16 ET200SP remote I/O stations around racking systems to control stacker cranes, sorting switches, photoelectric sensors and weighing analog signals. All stations use 6ES7155-6AU01-0CN0 to build a complete MRP redundant ring network.
Topology Design
Dual ports of all IM155 HF modules are cascaded end-to-end to form a large ring. Any single cable or interface module fault triggers automatic ring bypass switching; stacker cranes operate continuously without cargo jams. حتى 64 I/O slots per station enable centralized cabinet installation at rack ground level and reduce on-site sub-cabinet count.
Selection Explanation
While standard ST models support MRP, their low bus throughput leads to communication congestion and emergency stops of stacker cranes under concurrent heavy signal loads. The HF hardware doubles bus throughput capacity.
قضية 6: Wastewater Treatment Plant Retrofit & يرقي (Harsh Wide-Temperature Environment)
نظرة عامة على المشروع
Retrofit of remote I/O systems for aeration tanks, sedimentation tanks and chemical dosing rooms at a large municipal wastewater plant, replacing legacy ET200M hardware. Outdoor control cabinets face extreme temperature fluctuations and high humidity with condensation. A total of 9 units of 6ES7155-6AU01-0CN0 are deployed to collect dissolved oxygen, pH, liquid level and pump valve signals.
On-Site Adaptation Highlights
- Wide operating temperature range of -25 °C ~ +60 درجة مئوية, tolerating subzero winter conditions and high cabinet internal temperatures in summer.
- 1500 V AC electrical isolation between PN ports and backplane ensures stable communication under heavy interference from water pump inverters.
- Comprehensive cable diagnostics distinguish sensor open circuits, cable aging and ground faults.
- Fanless passive cooling eliminates dust accumulation failures in high-humidity wastewater environments, with MTBF exceeding 120,000 ساعات.
General Selection Summary (Mandatory Scenarios for 6AU01-0CN0 HF Model)
- Applications requiring IRT isochronous synchronization: multi-axis servo drives, الروبوتات, printing presses, lithium battery stacking equipment
- S7-1500R/H redundant systems requiring S2 multi-assigned I/O
- MRP redundant ring topologies where production line shutdown is unacceptable
- Demand for online hot swapping of I/O modules and granular single-channel diagnostics
- Multi-controller Shared Device I/O sharing and PROFIenergy energy management
- High-density stations (زيادة 32 I/O modules per station, with ET200AL remote extensions)
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية