Siemens Power Module 6SL3225-0BE31-1AA1

Model Code Decoding 6SL3225-0BE31-1AA1 6SL3225: G120 PM250 power module (supports energy regeneration, active rectification) 0BE: 3-phase 380~480 V AC input 31: كود تصنيف الطاقة 1: Built-in Class A EMC filter AA1: Standard version with regeneration capability Important Distinction: PM250 ≠ PM240. The PM250 features native regeneration capability to feed braking energy back to the grid; ...

  • تفاصيل المنتج

Model Code Decoding

6SL3225-0BE31-1AA1

6SL3225: G120 PM250 وحدة الطاقة (supports energy regeneration, active rectification)

0BE: 3-phase 380~480 V AC input

31: كود تصنيف الطاقة

1: Built-in Class A EMC filter

AA1: Standard version with regeneration capability

Important Distinction: PM250 ≠ PM240. The PM250 features native regeneration capability to feed braking energy back to the grid; external braking resistors are not required for heavy-duty braking applications.

  1. المعلمات الكهربائية الأساسية
غرضمواصفة
Input Supply3AC 380~480 V ±10%, 47~63 Hz
واجب ثقيل (عالية الدقة, Constant Torque)11 كيلوواط, تيار الإخراج 26 أ
الزائد: 200% ل 3 ق; 150% ل 57 ق; درجة الحرارة المحيطة: 0~+50°C
Light Duty (إل دي, Variable Torque)15 كيلوواط, تيار الإخراج 32 أ
الزائد: 150% ل 3 ق; 110% ل 57 ق; درجة الحرارة المحيطة: 0~+40°C
تردد الإخراج0~200 Hz
EMC ConfigurationBuilt-in Class A filter
الميزة الأساسيةActive front-end with grid energy regeneration (regenerative function)
فئة الحمايةIP20 (for cabinet mounting)
الأبعاد الشاملةارتفاع 334 mm × Width 189 mm × Depth 185 مم
الوزن الصافي7.5 كجم

⚠️ Control Unit (CU) not included. It must be combined with CU230P-2 / CU240E-2 / CU250S or other control units to form a complete frequency converter.

ثالثا. Key Feature Description

  1. Energy Regeneration

Energy generated during motor braking is fed back into the grid. Ideal for frequent start-stop equipment, hoists, centrifuges and downward conveyor lines. Compared with PM240 plus braking resistor solutions, it delivers higher energy efficiency and lower heat generation.

  1. Built-in Class A EMC Filter

Meets industrial EMC requirements and can be directly installed inside factory cabinets. Additional EMC evaluation is required for applications within commercial buildings.

  1. Modular G120 architecture: Free combination of power module and control unit, facilitating spare part replacement.
  2. مقارنة السلسلة & اختيار (For Replacement Reference)

6SL3225-0BE31-5AA1: PM250, 15 kW heavy duty, built-in Class A filter

6SL3225-0BE31-8AA1: PM250, 18.5 kW heavy duty

Models without integrated filters carry the suffix UA0 (على سبيل المثال. 6SL3225-0BE31-1UA1). Please avoid confusion.

  1. Typical Applicable Working Conditions

مصاعد, lifting equipment, الرافعات, downward conveyors

أجهزة الطرد المركزي, test benches and loads with frequent braking

Applications requiring braking energy recovery and prohibiting heat generation from braking resistors

  1. Selection Pitfall Reminders
  2. If energy regeneration is unnecessary, PM240 power modules (prefix 6SL3224) are available at lower cost.
  3. PM250 cannot directly replace PM240 due to different internal topologies.
  4. Derating is mandatory for light-duty operation above 40°C and heavy-duty operation above 50°C.
  5. Output reactors are recommended for long motor cables to reduce dv/dt and protect motor insulation.

6SL3225-0BE31-1AA1 (SINAMICS G120 PM250, 11 kW HD / 15 kW LD, Built-in Class A EMC Filter)

Core hardware characteristic: Active rectification, grid energy regeneration, no need for braking resistors to dissipate regenerative energy. This makes it the preferred choice for frequent braking, potential energy loads and continuous generating operating conditions. It is less cost-effective for unidirectional continuous operation with rare braking, such as ordinary fans and pumps.

Recap of Rated Capacity

واجب ثقيل (عالية الدقة): 11 كيلوواط, 26 أ; Light Duty (إل دي): 15 كيلوواط, 32 أ

مزود الطاقة: 3AC 380~480 V

PM250 = Regenerative power module, different from dissipative PM240

  1. Preferred Application Scenarios (Maximize Regeneration Benefits)
  2. Lifting & Hoisting Equipment (Potential energy loads generating power during descent)

Small overhead cranes, electric hoists, lifting platforms, parking lift mechanisms

Material elevators, elevator test benches, small freight elevator drives

Operating characteristic: Motors operate in generating mode when lowering loads. Regenerative power is fed back to the grid, eliminating heat from braking resistors and reducing cabinet temperature rise.

  1. Conveying Machinery (Downward Belt & Inclined Conveyors)

Downward inclined belt conveyors, gravity discharge belts

Roller drives with continuous downward transportation generating regenerative energy during deceleration or shutdown

Horizontal conveyors and upward conveyors rarely produce regenerative energy; PM250 is generally not prioritized.

  1. Test Equipment & High-Inertia Rotating Loads

Motor performance test benches, load test benches, inertia flywheel systems

High-speed centrifuges, winding/unwinding equipment (tension control, rapid acceleration & deceleration)

Frequent acceleration and emergency braking continuously generate regenerative energy, eliminating fire risks caused by overheated resistors.

  1. Tension Control for Winding & Unwinding Processes

Film, ورق, textile and cable winding/unwinding machines

Motors are passively driven during unwinding and continuously generate power. The regenerative solution removes the need for high-power braking resistors and reduces cabinet footprint.

  1. أدوات الآلة & Rotating Tooling

Large CNC rotary tables, turnover fixtures, grinding spindles with frequent forward/reverse rotation and rapid stopping

Suitable for automated machine stations with continuous cyclic processes requiring fast braking.

  1. Auxiliary Drives for Rail Transit & التعامل مع المواد

AGV charging test systems, small rail transfer vehicle drives, shuttle trolleys

  1. Usable but Not Recommended (Poor Cost Performance)

Regenerative energy is minimal in these applications; PM240 + braking resistor delivers lower initial investment:

Ordinary water supply pumps, مراوح برج التبريد, unidirectional ventilation fans

Standard horizontal conveyors, general mixers, unidirectional extruders

PM250 can only be considered if on-site restrictions apply: installation of braking resistors is forbidden, cabinet heat generation is prohibited, or space is insufficient to mount resistors.

ثالثا. سيناريوهات غير قابلة للتطبيق (Selection Red Lines)

  1. Equipment with high short-term impact loads, drives for explosion-proof motors (additional explosion protection assessment required; the module itself carries no explosion-proof certification)
  2. Offshore environments with high salt spray and heavy corrosion; protected cabinets are mandatory before installation
  3. Sites with poor grid quality and frequent power outages: PM250 active rectifiers are sensitive to grid fluctuations
  4. Multi-drive systems with shared DC bus: PM250 is a standalone regenerative module. For such applications, SINAMICS S120 should be adopted.
  5. Recommended Matching Control Units (Mandatory for the Power Module)

CU240E-2: General positioning and vector control; first choice for most automation equipment

CU230P-2: Fan/pump basic technology, suitable for simple speed regulation

CU250S: Supports closed-loop vector control with encoders; recommended for high-precision lifting and tension control applications

  1. Selection Comparison Tips for Same Power Rating
  2. Frequent braking / potential energy loads → 6SL3225-0BE31-1AA1 (PM250 regenerative type)
  3. Unidirectional operation with infrequent braking → 6SL3224 series PM240 + braking resistor for lower upfront cost

6SL3225-0BE31-1AA1 (PM250 Frame Size FSC) مواصفات الأبعاد

  1. Overall Dimensions of Power Module Body (Excluding Control Unit)

ارتفاع(ح) × Width(دبليو) × Depth(د) = 334 مم × 189 مم × 185 مم

حجم الإطار: FSC

الوزن الصافي: 7.5 كجم

فئة الحماية: IP20 (indoor cabinet installation)

Dimension Definition:

ارتفاع: Vertical mounting length (top to bottom)

عرض: Horizontal transverse dimension

عمق: Protrusion inward into the cabinet

  1. ملاحظات التثبيت الهامة (Cabinet Design Reference)
  2. Additional depth occupied by mounted control units

CU230P-2 / CU250S: Extra 65 mm forward extension

CU240E-2: Extra 40 mm forward extension

  1. Mandatory Cooling Clearances (سيمنز Official Specification)

Minimum clearance above module ≥100 mm; minimum clearance below ≥50 mm

Side-by-side installation: Maintain ≥1 mm gap; ≥5 mm recommended for high-heat operating conditions

  1. أجهزة التركيب

Fixed with 4 × M5 screws; mounting hole layout matches standard FSC mounting baseplates.

ثالثا. Common Confusion Reminder