Siemens QPL25.050B is a high-performance gas pressure switch. Designed for medium and low pressure monitoring ranging from 5-50 mbar, it features IP54 protection grade and a mechanical service life of 100,000 دورات. It is widely used for safety protection of combustion systems. Check model parameters, pressure range and mounting interface during procurement to ensure full compatibility with system requirements.
- تعريف رمز النموذج
| مقطع الكود | معنى | وصف |
| QPL | رمز سلسلة المنتج | Basic series of Siemens gas pressure switches for gas and air pressure monitoring |
| 25 | بناء & المعلمات المقدرة | مسلسل 25, rated current 6A AC, الجهد المقنن 250 فولت تيار متردد/تيار مستمر, حماية IP54 |
| 50 | Pressure adjustment range | Adjustable range: 5-50 mbar (0.5-5.0 kPa) |
| ب | Version mark | النوع القياسي, automatic reset, SPDT contact configuration |
- معلمات المواصفات الأساسية
| فئة | تحديد | ملاحظات |
| المعلمات الأساسية | ||
| نوع المنتج | Mechanical gas pressure switch | Safety monitoring for combustion systems |
| رقم الطلب. | 1117087 | Official Siemens part number |
| Adjustment Range | 5-50 mbar (0.5-5.0 kPa) | Adjustable set point |
| Max Working Pressure | 690 mbar (69 kPa) | Upper limit of continuous operating pressure |
| Switch Differential | تقريبا. 5-10 mbar | Pressure difference between switch-on and switch-off |
| المعلمات الكهربائية | ||
| الجهد المقنن | AC 250V / DC 250V | أقصى جهد التشغيل |
| التصنيف الحالي | AC 6A / DC 1A | حمل مقاوم |
| Contact Type | SPDT | 1 مفتوحة عادة + 1 مغلقة عادة |
| التوصيل الكهربائي | Terminal box compliant with DIN EN 175 301-803 | فصل 3 حماية العزل |
| ميكانيكية & المعلمات البيئية | ||
| Pressure Port | G1/4 internal thread (ISO228) | Center position at bottom casing |
| Measuring Port | Ø9mm, 10mm length with locking screw | For pressure calibration |
| درجة الحرارة المحيطة | -20درجة مئوية ~ +60 درجة مئوية | نطاق درجة حرارة التشغيل |
| درجة حرارة متوسطة | -40درجة مئوية ~ +60 درجة مئوية | Applicable gas temperature |
| درجة الحماية | IP54 | مقاوم للغبار ومقاوم للماء |
| Mechanical Lifespan | 100,000 دورات | Switch actuation times |
| Applicable Media | فصل 1/2/3 gases & non-corrosive gas | Natural gas, liquefied petroleum gas, إلخ. |
- Full QPL25 Series Model List
| نموذج | Pressure Range | Max Working Pressure | ملاحظات |
| QPL25.003B | 0.3-3 mbar | 690 mbar | Low pressure monitoring |
| QPL25.010B | 1-10 mbar | 690 mbar | Ultra-low pressure application |
| QPL25.050B | 5-50 mbar | 690 mbar | Standard medium-low pressure |
| QPL25.150B | 15-150 mbar | 690 mbar | Medium pressure monitoring |
| QPL25.500B | 100-500 mbar | 720 mbar | High pressure monitoring |
- Cross-brand Replacement Comparison
| ماركة | نموذج | Pressure Range | الاختلافات الرئيسية | اقتراح الاستبدال |
| سيمنز | QPL25.050B | 5-50 mbar | Original authentic product, استقرار عالي | Priority choice |
| هانيويل | C6097A | 5-50 mbar | سعر منخفض, similar response speed | الاستبدال المباشر |
| دانفوس | KPI 36 | 5-50 mbar | هيكل ميكانيكي مختلف, high adjustment precision | Verify mounting dimensions |
| Dungs | LGW50A2 | 5-50 mbar | German brand, reliable quality | متوافقة تماما |
| Baltur | PAMPA | 5-50 mbar | Burner dedicated, فعالة من حيث التكلفة | Suitable for Baltur combustion systems |
- استكشاف الأخطاء وإصلاحها الشائعة & صيانة
5.1 الأخطاء الشائعة & Causes
| ظاهرة الخلل | الأسباب المحتملة | خطوات استكشاف الأخطاء وإصلاحها |
| No switch action under normal pressure | Improper setpoint; oxidized/damaged contacts; aging/damaged diaphragm; loose wiring | Recalibrate setpoint; test contact continuity; inspect diaphragm; fasten terminals |
| No switching under abnormal pressure | Excessive switch differential; mechanical stuck; spring fatigue | Adjust differential; clean moving parts; replace spring assembly |
| Frequent contact ablation | الزائد; unstable voltage; mismatched contact material | Check load current; install surge suppressor; replace contact assembly |
| Inaccurate pressure reading | Blocked measuring port; deformed diaphragm; calibration error | Clean port; replace diaphragm; recalibrate with standard pressure source |
5.2 إرشادات الصيانة
- Safety Precaution
Cut off gas supply and release pressure
Disconnect power supply
Cool down equipment to room temperature
- Calibration Procedure
① Remove protective cover and locate adjusting screw
② Connect standard pressure source and set target value
③ Clockwise rotation increases set pressure, counter-clockwise decreases
④ Test switching action and confirm accurate trigger point
⑤ Reinstall cover and ensure tight sealing
- Component Replacement
Diaphragm: Dismount with special tools, pay attention to gasket installation direction
اتصال: Replace whole switch module instead of single contact
Spring: Use identical specification spare part to guarantee precision
- بيئة التطبيق & حالات الصناعة
6.1 السيناريوهات القابلة للتطبيق
✅ Recommended Applications
Safety monitoring for industrial & civil gas burners
Pressure protection system of gas boilers
Pressure control of natural gas pipelines
Gas supply system of industrial furnaces
Pressure monitoring for biogas power generation equipment
❌ Inadmissible Applications
High-pressure gas system over 690 mbar
Corrosive gas atmosphere
Medium temperature exceeding 60°C or below -20°C
Severe vibration and outdoor exposed installation without protection
6.2 Typical Industry Applications
| صناعة | طلب | وظيفة |
| التدفئة والتهوية وتكييف الهواء | Commercial gas boiler | Monitor gas pressure to ensure combustion efficiency and safety |
| Food Processing | Baking furnace gas system | Avoid incomplete combustion caused by low pressure |
| Energy Industry | Biogas power station | Stabilize biogas pressure and protect generating units |
| تصنيع | Ceramic kiln | Precise temperature control via gas pressure regulation |
| Commercial Kitchen | Large cooking equipment | Safety interlock to prevent gas leakage accidents |
- نصائح الاختيار & Avoidable Risks
Selection Mnemonic
QPL series for gas service, 25 stands for 6A rating
Last three digits define pressure range, B means standard auto-reset
050 model fits 5-50 mbar, G1/4 thread for installation
IP54 solid protection, match gas medium properly
الملاحظات الرئيسية
- Pressure Matching
Keep actual working pressure within 20%-80% of adjustment range to maintain accuracy.
- متطلبات التثبيت
Mount vertically with diaphragm downward to avoid condensed water accumulation.
Install filter at pressure port to prevent internal impurity damage.
Secure wiring firmly to avoid false triggering.
- Safety Regulations
Interlock with gas leakage alarm device.
Conduct regular inspection and calibration every 6 شهور.
Perform pressure and leakage test after maintenance.
- Purchase Notice
Choose genuine Siemens products; counterfeit items have unstable quality.
Keep original package and certificate for after-sales service.
Working Principle of QPL25.050B
Core principle: Air pressure deforms diaphragm, mechanical linkage drives contact on-off to realize overpressure interlock protection
- Pressure Sensing
Gas flows into inner chamber through G1/4 port and acts on rubber diaphragm, driving axial displacement with pressure variation.
- Mechanical Force Balance
Diaphragm thrust counterbalances preset spring tension. Rotate adjusting screw to change spring preload and set trigger pressure threshold.
- Linkage Actuation
When pressure rises to set value, diaphragm overcomes spring resistance and pushes rod to drive lever mechanism. Spring rebounds when pressure drops below threshold.
- Contact Switching
Lever movement switches SPDT contacts, reverses circuit status and transmits electric signal for burner start-stop and alarm interlock.
- Differential Pressure Stabilization
Fixed pressure differential prevents frequent switching and unnecessary equipment startup/shutdown.
- وضع إعادة الضبط
Standard automatic reset; contacts recover initial state once pressure returns to normal range.
Application Scenarios of QPL25.050B
Applicable Sites
- Low pressure monitoring and protection for gas boilers and water heaters
- Supply pressure interlock control of oil and gas industrial burners
- Pressure stabilization detection for commercial kitchen stoves and hot air furnaces
- Medium-low pressure monitoring of natural gas and liquefied gas pipelines
- Safety protection for furnace and drying equipment gas supply
- Start-stop interlock for clean combustible gas such as biogas and coal gas
Forbidden Sites
- Gas pipelines with pressure higher than 690mbar
- Gas medium containing corrosion, dust and oil contaminants
- Ambient temperature below -20℃ or above 60℃
- Sites with fierce vibration and uncovered outdoor installation
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

















NH42-63-318x560.png)