CHINT Circuit Breakers’ Core Differences

The core differences of CHINT circuit breakers lie in       series positioning, breaking capacity, tripping characteristics, pole specifications, expansion functions, application scenarios, and price      . Miniature circuit breakers (MCBs) are mainly used for residential applications, while molded – case circuit breakers (MCCBs) and air circuit breakers (ACBs) are preferred for industrial purposes. Selection should match the load requirements and budget constraints.

  1. Core Series Classification and Positioning
SeriesTypeCore PositioningTypical Scenarios
DZ47 (including DZ47S)Miniature Circuit Breaker (MCB)Classic basic model with high cost – effectivenessOld projects, budget – friendly residential decoration, and small – scale commercial power distribution
NXB/NXBLEMiniature Circuit Breaker/Residual Current Circuit Breaker with Overcurrent Protection (MCB/RCBO)Upgraded version of DZ47, core model of Kunlun SeriesResidential decoration, small – scale projects requiring basic protection and modular expansion
NB3/NB6/NBE7Miniature Circuit Breaker/Residual Current Circuit Breaker with Overcurrent Protection (MCB/RCBO) (Taiji Series)High – end for home decoration, balancing appearance and performanceHigh – end finished residential buildings, smart homes, and home decoration with high safety and appearance requirements
NXMMolded – Case Circuit Breaker (MCCB)Power distribution and motor protection, medium – capacityIndustrial power distribution, building power distribution, and motor circuits (63A–1600A)
NM5Molded – Case Circuit Breaker (MCCB)High – performance MCCB with high breaking capacity and intelligenceNew energy projects, large – scale infrastructure, and high – reliability industrial power distribution
NA1/NA8Air Circuit Breaker (ACB)Large – capacity main switch with intelligent coordinated controlMain incoming lines of distribution rooms and main circuits of large factories (800A–6300A)
  1. Key Technical Parameter Differences (Core Comparison Between Miniature and Molded – Case Circuit Breakers)
  2. Core Differences of Miniature Circuit Breakers (MCB/RCBO)
ParameterDZ47NXBNB6NBE7NB3
Breaking Capacity6kA6kA (better arc – extinguishing performance)6kA/10kA (high – end models)6kA6kA
Tripping CurveB/C/DC/D (higher precision)C/D (10mA residual current protection optional)C/DC/D
Pole Configuration1P/1P+N/2P/3P/4P1P/1P+N/2P/3P/4P1P/1P+N/2P/3P/4P1P/2P/3P/4P1P/1P+N/2P/3P/4P
Rated Current6A–63A6A–63A6A–63A16A–40A (50/63A not available)6A–63A
Expansion FunctionsBasicSupports shunt trip, under – voltage trip, and alarm accessoriesSupports intelligent accessories and 10mA residual current protectionBasicSlim design (18mm), appearance – oriented
PriceLowestLow – mediumMedium – highMedium (high cost – effectiveness)Medium
  1. Core Differences of Molded – Case Circuit Breakers (MCCB)
ParameterNXMNM5
Rated Current63A–1600A16A–1000A
Ultimate Short – Circuit Breaking Capacity (Icu)25kA–50kA36kA–70kA
Service Short – Circuit Breaking Capacity (Ics)50%–100% of Icu100% of Icu
Accessory ExpansionRegular modularizationCan be equipped with 4 types of accessories, miniaturized design
Intelligent FunctionsBasic protectionSmart IoT connectivity and remote monitoring

III. Key Selection Points (By Scenario)

  1.  Residential Decoration Selection

Budget – priority: NBE7 (16A–40A) or NXB, featuring high cost – effectiveness.

Safety – priority: NB6 (10mA residual current protection) or NB3 (slim design), suitable for families with infants and young children and smart homes.

Old house renovation: Direct replacement with DZ47 without modifying the air – conditioning circuit.

Circuit Breaker TypeSeriesRated Current RangeBreaking CapacityCore ApplicationTypical Scenarios
Molded – Case Circuit Breaker (MCCB)NXM, NXMS16A–1600A25kA–70kAProtection for power distribution trunk lines and power equipmentIndustrial power distribution, large – capacity loads, and generators
Air Circuit Breaker (ACB)NA1, NXA, NA5400A–6300A50kA–120kAProtection for main incoming lines and busbars of power gridsFactory distribution rooms, data centers, and main power distribution of buildings
  1. Comparison of Mainstream Miniature Circuit Breaker (MCB) Series (High – frequency for Sales)

MCBs are crucial for end – user selection. The following are the key differences among CHINT’s most commonly used MCB series, which directly affect quotation and customer communication:

ParameterNXB (Upgraded Version of DZ47)NB6NBE7DZ47 (Classic Model)
Breaking Capacity10kA6kA6kA6kA
Tripping CharacteristicsType B/C/DType C/DType C/DType C/D
Pole Configuration1P/1P+N/2P/3P/4P1P/1P+N/2P/3P/4P1P/2P/3P/4P1P/2P/3P/4P
Rated Current6A–125A (including 125G)6A–63A16A–40A6A–63A
Expansion FunctionsSupports shunt trip, under – voltage trip, and alarm accessoriesBasic model with few accessoriesBasic model with red – green indicatorNo expansion accessories
Price PositioningMid – range (high cost – effectiveness)Mid – to high – end (appearance – priority)Entry – level (lowest price)Economy – class (being phased out)
Selection SuggestionMainstream choice for residential and commercial useHigh – end home decoration and smart homesBudget – constrained and small – current branch circuitsRenovation of old projects and temporary power supply

 

  1. Differences in Key Technical Parameters (Frequently Asked by Customers)
  2.  Tripping Characteristics

Type B: Tripping current of 3In–5In, suitable for sensitive electronic equipment such as computers and PLCs.

Type C: Tripping current of 5In–10In, suitable for general loads like lighting and ordinary sockets (mainstream for residential use).

Type D: Tripping current of 10In–20In, suitable for loads with high starting inrush current such as motors, air conditioners, and compressors.

  1.  Pole Selection

1P: Only disconnects the live wire (L), used for low – power branch circuits like lighting, with the lowest cost.

1P+N: Disconnects the live wire and monitors the neutral wire (N), cost – effective and suitable for ordinary sockets.

2P: Disconnects both the live wire and neutral wire simultaneously, highly safe, used for high – power household appliances such as air conditioners and water heaters.

3P/4P: Used for three – phase equipment (e.g., industrial motors and water pumps). 3P disconnects three – phase live wires, and 4P disconnects three – phase live wires plus the neutral wire.

  1.  Breaking Capacity

– Breaking capacity determines whether a circuit can be reliably disconnected during a short – circuit. For residential use, a breaking capacity of over 6kA is recommended; for industrial and commercial applications, over 10kA is advisable to prevent arc faults.

  1. Quick Selection Guide (For Fast Customer Recommendations)

Regular residential use: NXB Series (10kA breaking capacity, full pole configurations, expandable with accessories, suitable for most residential decoration projects).

Budget – constrained: NBE7 (low price, with status indicators, suitable for small – current branch circuits).

High – end residential decoration: NB6 (elegant appearance, complete specifications, suitable for smart homes and demanding customers).

Industrial power applications: Prioritize NXM molded – case circuit breakers or NA Series air circuit breakers, as their breaking capacity and accessories are better suited for heavy – duty loads.

VII. Core Differences from Competitors (ABB, Schneider)

Price: CHINT’s products are 15%–30% cheaper than ABB and Schneider products of the same specifications, boasting a distinct cost – effectiveness advantage, which is suitable for budget – sensitive customers.

Accessory ecosystem: CHINT’s modular accessories (e.g., shunt trip and under – voltage trip) are more affordable and highly compatible, facilitating quotation combinations.

Breaking capacity: Low – to mid – range MCBs (e.g., DZ47) have a breaking capacity of 6kA, while the mainstream NXB Series reaches 10kA, which is on par with the mid – range series of international brands.

 