Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

Cross-Brand Equivalent for Acti9 iPRD1 12.5r 3P+N (A9L16482) SPD - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

NewsTrade News

Cross-Brand Equivalent for Acti9 iPRD1 12.5r 3P+N (A9L16482) SPD

Below are Type 1+2 combined surge protective devices from major electrical brands that match the performance parameters of Schneider A9L16482 (Acti9 iPRD1 12.5r 3P+N). All are suitable for 3P+N three‑phase four‑wire systems, equipped with remote signaling, and can be used as direct replacements or functionally equivalent solutions.

Core Matching Parameters (Schneider A9L16482)

ItemSpecification
Protection TypeType 1+2 Combined (Protection against direct & indirect lightning)
Pole Configuration3P+N (3 Phases + Neutral)
Impulse Current (Iimp, 10/350μs)12.5kA
Max. Discharge Current (Imax, 8/20μs)50kA
Rated Voltage (Uc)350V AC (phase‑to‑phase), 255V AC (neutral‑to‑earth)
Voltage Protection Level (Up)1.5kV (phase‑to‑phase), 1kV (neutral‑to‑earth)
Remote FunctionWith remote signaling contacts
Installation Width4 modules (72mm)
TechnologyMOV + GDT hybrid
Earthing SystemCompatible with TN‑S and TT systems

Equivalent Models & Parameter Comparison by Brand

  1. ABB Equivalent
ModelKey ParametersDifference from ReferenceApplication
OVR ZP T1-T2 3N 12.5-255 (2CTB815799R1300)• Type 1+2Uc = 255V (neutral‑to‑earth of reference); phase‑to‑phase protection to be confirmedMain switchboards in residential & commercial buildings; direct interchange with Schneider
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=255V
• Up=1.5kV
• With remote signaling
OVR ZP+ 3N 12.5-255 (2CTB815799R1900)• Type 1+2+3 protectionExtra Type 3 protection, more comprehensiveSmart buildings with high surge protection requirements; no additional downstream SPD needed
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=255V
• 4 modules
  1. Siemens Equivalent
ModelKey ParametersDifference from ReferenceApplication
5SD7414-2RC• Type 1+2Fully matches core parameters; standard Siemens 5SD74 modelIndustrial & commercial buildings; compatible with Siemens distribution systems
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=350V
• Up=1.5kV
• With remote status contacts (RSC)
5SD74141RC• Type 1+2Uc and Up slightly higher; suitable for unstable voltage gridsBuilding distribution in areas with unstable power supply
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=385V
• Up=1.8kV
• Remote signaling
  1. CHINT Equivalent
ModelKey ParametersDifference from ReferenceApplication
NXU-Ⅰ+Ⅱ 12.5/385 3P+N• Type 1+2Uc and Up slightly higher; better priceBudget‑sensitive residential & small commercial projects
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=385V
• Up=1.8kV
• Optional remote signaling module
NU5-Ⅰ+Ⅱ 12.5/385 3P+N• Type 1+2Higher Imax, stronger protectionIndustrial plants, large commercial complexes
• 3P+N
• Iimp=12.5kA
• Imax=65kA
• Uc=385V
• Up=2kV
• Remote monitoring
  1. Delixi Equivalent
ModelKey ParametersDifference from ReferenceApplication
CDYN-I+II 12.5/350 3P+N• Type 1+2Fully matches core parameters; Delixi premium seriesProjects with mixed Schneider systems
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=350V
• Up=1.5kV
• Remote signaling output
CDYE-I+II 12.5/385 3P+N• Type 1+2Added local alarm for on‑site inspectionUnmanned power distribution areas
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=385V
• Up=1.8kV
• Audible‑visual alarm + remote signaling
  1. Other International Brands
BrandModelKey ParametersAdvantages
Phoenix ContactVAL-MS 3P+N PE 12.5 350V• Type 1+2Modular design, hot‑swap, easy maintenance
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=350V
• Up=1.5kV
DEHNDS254 3P+N 12.5-350• Type 1+2Made in Germany, IP20, long service life
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=350V
• Up=1.5kV
LegrandP1+P2 3P+N 12.5 350V• Type 1+2Perfect compatibility with Legrand enclosures, easy installation
• 3P+N
• Iimp=12.5kA
• Imax=50kA
• Uc=350V
• Up=1.5kV

Key Considerations for Replacement Selection

  1. Parameter Matching Priority: Ensure the four core parameters Iimp, Imax, Uc, Up match system requirements, as they directly affect surge protection performance and equipment safety.
  2. Remote Function Compatibility: Verify remote contact type (dry/wet) and operating voltage (DC 24V / AC 230V) match the existing monitoring system.
  3. Installation Size: 4 modules (72mm) is standard for most brands, but confirm actual space.
  4. Earthing Compatibility: Ensure the model supports the on‑site earthing system (TN‑S / TT / TN‑C‑S).
  5. Price & Warranty: Chinese brands (CHINT, Delixi) are typically 20–40% lower, with 1–2 year warranty; international brands usually offer 2–5 years.

Selection Recommendations

Direct Replacement:

ABB OVR ZP T1-T2 3N 12.5-255, Siemens 5SD7414-2RC, Delixi CDYN-I+II 12.5/350 3P+N fully match Schneider A9L16482 and can be interchanged directly.

Performance Upgrade:

Choose CHINT NU5 series (Imax 65kA) or ABB OVR ZP+ series (Type 1+2+3) for higher protection level.

Cost Optimization:

Chinese brands (CHINT NXU, Delixi CDYE) significantly reduce cost while meeting basic protection needs.

Prev:

Leave a Reply

Leave a message