Marke: Pentronik (Schweden), a Nordic manufacturer of high-precision Temperatursensoren. Der 5810080 Serie ist ein zusammengebauter industrieller Pt100-Widerstandstemperaturdetektor (FTE). It is often mistakenly referred to as a thermocouple in the industry; this distinction is critical.
- Erklärung des Modellcodes
5810080: Produktserie, assembled industrial platinum RTD with terminal head and protection thermowell
-001: Version / construction suffix, representing single Pt100 element, Class A accuracy, base version with standard thermowell material, probe length and thread specification
Other variants within the series include 5810080-002 Und 5810080-003, commonly dual Pt100 elements, alternative probe lengths or pressure ratings.
- Grundlegende technische Spezifikationen
| Artikel | Spezifikation |
| Sensorelement | Pt100 Platinum RTD (compliant with IEC60751) |
| Genauigkeitsklasse | Klasse A |
| Temperaturbereich | -200℃ ~ +500℃ (depends on thermowell material) |
| Verkabelungskonfiguration | Standard 4-wire (3-wire optional). The 4-wire design eliminates lead resistance error and is preferred for high-precision measurement |
| Thermowell Material | 316L Edelstahl (Standard); Hastelloy or Titanium optional for highly corrosive media |
| Probe Construction | Solid mineral-insulated / drilled protection tube, vibration-resistant structure (Pentronic thermally conductive filling for faster response) |
| Terminal Head | Aluminium waterproof head, IP65; built-in temperature transmitter optional (4-20mA-Ausgang) |
| Montage | Threaded installation (G1/2, M20×1.5 commonly used), compatible with protection thermowell |
| Ansprechzeit | t0.5: ca. 2~8s (in liquid media, subject to probe diameter) |
| SIL | SIL2 loop assessment available (dual-element version 5810080-002) |
- Kernfunktionen
- Excellent stability: Class A platinum wire with annual drift as low as 0.05℃, suitable for long-term continuous process measurement
- Vibration-resistant construction: Internal metal filling reduces air gaps, withstands vibration for temperature measurement on compressor, pump and turbine casings
- Replaceable insert: Sensing element is a removable insert. Sensor core can be replaced without removing the thermowell, cutting downtime maintenance cost
- Corrosion-resistant options: Custom Hastelloy and Monel thermowells available for corrosive chemical service
- Optionales Zubehör: Built-in HART temperature transmitter providing direct 4–20mA signal to DCS/PLC
- Typische Anwendungsszenarien

Pentronik 5810080-001 Temperatursensor
Thermal power, Öl & Gas, chemisch, paper and pharmaceutical industries; temperature measurement of pipelines, equipment casings and tank media; high-precision temperature acquisition for TSI and process control loops.
Frequently paired with Bently Nevada TSI systems for unit temperature monitoring.
- Installation & Inbetriebnahmerichtlinien
- Installation: Protection thermowell is recommended for online replacement. Probe insertion depth ≥ 8~10 times thermowell inner diameter to ensure accurate temperature reading
- Verdrahtung: 4-wire Pt100 with two excitation wires and two measurement wires. Must not be used with thermocouple extension wires
- Abschirmung: Cable shield single-point grounded inside terminal head to avoid common-mode interference; Verlegen Sie es nicht in der Nähe von Stromkabeln
- Kalibrierung: Kalibrieren Sie Widerstandswerte gemäß IEC60751 mit einem Trockenblockkalibrator oder einem Ölbad mit konstanter Temperatur
- Explosionsgeschützte Ausführungen: Ab jetzt / Ex d verfügbar; Zertifikate müssen für die Auswahl des Gefahrenbereichs überprüft werden
- Allgemeine Checkliste zur Fehlerbehebung
- Temperaturschwankungen: Lose Kabelverbindungen, Mehrpunkterdung des Schirms, Lösen der Klemmen durch Feldvibrationen
- Anhaltend hoch / niedrige Messwerte: Sonde ist nicht vollständig in das Medium eingetaucht, verschmutztes Schutzrohr, übermäßiger Leitungswiderstand (auf 4-Draht-Konfiguration umstellen)
- Alarm bei offenem Stromkreis: Gebrochener Platindraht oder Biegeschaden an der Wurzel (kommt häufig unter vibrierenden Bedingungen vor)
- Erhöhte Drift: Alterung des Platinelements nach längerem Übertemperaturbetrieb
- Serienalternative & Auswahlreferenz
| Modell | Konstruktion | Anwendung |
| 5810080-001 | Einzelner Pt100, Klasse A | Einpunkt-Temperaturmessung für allgemeine Prozesse |
| 5810080-002 | Dual Pt100, Klasse A/A | Redundante Messung, SIL2-Schleife |
| 5810080-003 | Einzelnes Element, erweiterte Sonde / high-pressure thermowell | Deep insertion, high-pressure pipelines |
Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter