Pentronik 5810080-001 Temperatursensor - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

 Pentronik 5810080-001 Temperatursensor - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Handelsnachrichten

Pentronik 5810080-001 Temperatursensor

Marke: Pentronik (Schweden), a Nordic manufacturer of high-precision Temperatursensoren. Der 5810080 Serie ist ein zusammengebauter industrieller Pt100-Widerstandstemperaturdetektor (FTE). It is often mistakenly referred to as a thermocouple in the industry; this distinction is critical.

  1. Erklärung des Modellcodes

5810080: Produktserie, assembled industrial platinum RTD with terminal head and protection thermowell

-001: Version / construction suffix, representing single Pt100 element, Class A accuracy, base version with standard thermowell material, probe length and thread specification

Other variants within the series include 5810080-002 Und 5810080-003, commonly dual Pt100 elements, alternative probe lengths or pressure ratings.

  1. Grundlegende technische Spezifikationen
ArtikelSpezifikation
SensorelementPt100 Platinum RTD (compliant with IEC60751)
GenauigkeitsklasseKlasse A
Temperaturbereich-200℃ ~ +500℃ (depends on thermowell material)
VerkabelungskonfigurationStandard 4-wire (3-wire optional). The 4-wire design eliminates lead resistance error and is preferred for high-precision measurement
Thermowell Material316L Edelstahl (Standard); Hastelloy or Titanium optional for highly corrosive media
Probe ConstructionSolid mineral-insulated / drilled protection tube, vibration-resistant structure (Pentronic thermally conductive filling for faster response)
Terminal HeadAluminium waterproof head, IP65; built-in temperature transmitter optional (4-20mA-Ausgang)
MontageThreaded installation (G1/2, M20×1.5 commonly used), compatible with protection thermowell
Ansprechzeitt0.5: ca. 2~8s (in liquid media, subject to probe diameter)
SILSIL2 loop assessment available (dual-element version 5810080-002)
  1. Kernfunktionen
  2. Excellent stability: Class A platinum wire with annual drift as low as 0.05℃, suitable for long-term continuous process measurement
  3. Vibration-resistant construction: Internal metal filling reduces air gaps, withstands vibration for temperature measurement on compressor, pump and turbine casings
  4. Replaceable insert: Sensing element is a removable insert. Sensor core can be replaced without removing the thermowell, cutting downtime maintenance cost
  5. Corrosion-resistant options: Custom Hastelloy and Monel thermowells available for corrosive chemical service
  6. Optionales Zubehör: Built-in HART temperature transmitter providing direct 4–20mA signal to DCS/PLC
  7. Typische Anwendungsszenarien
Pentronik 5810080-001 Temperatursensor

Pentronik 5810080-001 Temperatursensor

Thermal power, Öl & Gas, chemisch, paper and pharmaceutical industries; temperature measurement of pipelines, equipment casings and tank media; high-precision temperature acquisition for TSI and process control loops.

Frequently paired with Bently Nevada TSI systems for unit temperature monitoring.

  1. Installation & Inbetriebnahmerichtlinien
  2. Installation: Protection thermowell is recommended for online replacement. Probe insertion depth ≥ 8~10 times thermowell inner diameter to ensure accurate temperature reading
  3. Verdrahtung: 4-wire Pt100 with two excitation wires and two measurement wires. Must not be used with thermocouple extension wires
  4. Abschirmung: Cable shield single-point grounded inside terminal head to avoid common-mode interference; Verlegen Sie es nicht in der Nähe von Stromkabeln
  5. Kalibrierung: Kalibrieren Sie Widerstandswerte gemäß IEC60751 mit einem Trockenblockkalibrator oder einem Ölbad mit konstanter Temperatur
  6. Explosionsgeschützte Ausführungen: Ab jetzt / Ex d verfügbar; Zertifikate müssen für die Auswahl des Gefahrenbereichs überprüft werden
  7. Allgemeine Checkliste zur Fehlerbehebung
  8. Temperaturschwankungen: Lose Kabelverbindungen, Mehrpunkterdung des Schirms, Lösen der Klemmen durch Feldvibrationen
  9. Anhaltend hoch / niedrige Messwerte: Sonde ist nicht vollständig in das Medium eingetaucht, verschmutztes Schutzrohr, übermäßiger Leitungswiderstand (auf 4-Draht-Konfiguration umstellen)
  10. Alarm bei offenem Stromkreis: Gebrochener Platindraht oder Biegeschaden an der Wurzel (kommt häufig unter vibrierenden Bedingungen vor)
  11. Erhöhte Drift: Alterung des Platinelements nach längerem Übertemperaturbetrieb
  12. Serienalternative & Auswahlreferenz
ModellKonstruktionAnwendung
5810080-001Einzelner Pt100, Klasse AEinpunkt-Temperaturmessung für allgemeine Prozesse
5810080-002Dual Pt100, Klasse A/ARedundante Messung, SIL2-Schleife
5810080-003Einzelnes Element, erweiterte Sonde / high-pressure thermowellDeep insertion, high-pressure pipelines

Vorher: