Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

A9F18325-IC65N-3P-C25A Schneider Circuit Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Leistungsschalter/

A9F18325-IC65N-3P-C25A Schneider Circuit Breaker

Model Breakdown Code Description A9F18325 Official order number for Schneider Electric Acti9 iC65N Miniature Circuit Breaker IC65N Product series: Acti9 iC65 series, N-type breaking capacity (6Die), thermal-magnetic trip unit 3P Number of poles: 3 Stangen (3-phase 3-wire), can switch off three phases simultaneously C25A C-curve tripping, rated current 25A (at 30°C) Key Technical Parameters Item ...

  • Produktdetails
  1. Model Breakdown
CodeBeschreibung
A9F18325Official order number for Schneider Electric Acti9 iC65N Miniatur-Leistungsschalter
IC65NProduct series: Acti9 iC65 series, N-type breaking capacity (6Die), thermal-magnetic trip unit
3PNumber of poles: 3 Stangen (3-phase 3-wire), can switch off three phases simultaneously
C25AC-curve tripping, rated current 25A (at 30°C)
  1. Wichtige technische Parameter
ArtikelSpezifikation
MarkeSchneider Electric
ProduktserieActi9 iC65N
TypMiniatur-Leistungsschalter (MCB), thermal-magnetic trip
Nennstrom25A (at 30°C)
Polen3P (3 protective poles)
AuslösekurveC-curve (instantaneous trip at 5–10In, for distribution and lighting circuits)
Bruchkapazität6Die (compliant with IEC/EN 60898-1)
Nennspannung400V und (3-Phase), 230V und (single-phase)
Nennfrequenz50/60Hz
Montage35mm standard DIN rail mounting
Ambient ConditionsTemp: -25°C ~ +40°C, Höhe ≤2000m, humidity ≤95% (nicht kondensierend)
ProtectionÜberlastschutz (thermal trip) und Kurzschlussschutz (magnetic trip)
  1. Produktmerkmale
  2. Hohe Zuverlässigkeit: Thermal-magnetic tripping provides accurate overload and short-circuit protection
  3. Modularer Aufbau: Kompakte Größe, saves panel space, easy installation and maintenance
  4. Wide Application: For all low-voltage distribution systems: residential, commercial and industrial
  5. Certifications: Entspricht IEC/EN 60898-1, GB10963.1 and other international & national standards
  6. Long Service Life: Mechanical life ≥20,000 operations, electrical life ≥5,000 operations
  7. Anwendungen

3‑phase distribution systems: Overload and short-circuit protection for 3‑phase circuits

Beleuchtungskreise: 3‑phase lighting protection in large commercial buildings and industrial plants

Power equipment: Control and protection of small 3‑phase motors, Pumps, Fans, usw.

Distribution boards / cabinets: Main or branch switch for low-voltage distribution systems

  1. Replacement Models & Cross-Brand Comparison

5.1 Schneider Same-Series Replacements

ModellUnterschiedApplication Change
A9F1832020A, C-curve, 3PFor lower load current
A9F1833232A, C-curve, 3PFor higher load current
A9F1932525A, D-curve, 3PFor inductive loads such as motors
A9F1822525A, C-curve, 2PSingle-phase circuit protection
  1. Installation & Nutzungshinweise
  2. Vor der Installation, confirm model matches system parameters: check rated current, poles and tripping curve
  3. Must be mounted on standard 35mm DIN rail for secure installation
  4. Ensure terminals are tightly connected to avoid overheating
  5. Inspect breaker status regularly to ensure proper tripping mechanism
  6. After a fault trip, eliminate the cause before manually resetting
  7. Auswahlempfehlungen
  8. C-curve is suitable for distribution and lighting circuits; not recommended for frequent-start motors (use D-curve)
  9. 3P breakers are for 3-phase 3-wire systems; use 4P if neutral protection is required
  10. 6kA breaking capacity is for general industrial & Gewerbebauten; use higher-rated types (z.B. H-type 10kA) for high short-circuit current

Recommended Replacements for A9F18325-IC65N-3P-C25A

  1. Direkter Ersatz (Schneider Electric)
ErsatzmodellBestell-Nr.SchlüsselparameterUnterschiedAnwendung
IC65N 3P C25AA9F183253P, C25A, 6DieIdentisch, originalSame distribution protection
IC65N 3P C20AA9F183203P, C20A, 6Die20A (untere)3-phase lighting / distribution with lower load
IC65N 3P C32AA9F183323P, C32A, 6Die32A (higher)3-phase lighting / distribution with higher load
IC65N 3P D25AA9F193253P, D25A, 6DieD-curve (10–14In trip)3-phase motors, compressors and inductive loads
IC65H 3P C25AA9F283253P, C25A, 10Die10Die (höhere Bruchkapazität)Industrial environments with high short-circuit current
IC65L 3P C25AA9F383253P, C25A, 15Die15Die (highest level)Critical power systems with very high fault current
IC65N 4P C25AA9F184254P, C25A, 6Die4 Stangen (includes neutral protection)3-phase 4-wire systems
  1. Upgraded Replacements (New Schneider Series)
SerieModellBestell-Nr.Upgrade AdvantageAnwendung
Acti9 IC60NIC60N 3P C25AA9F58325More compact, higher short-circuit withstandNew projects with limited panel space
Acti9 IC40NIC40N 3P C25AA9P58325Ultra-slim (18mm/pole), space-savingSmall distribution boards, residential / kommerziell
  1. Cross-Brand Equivalent Replacements
MarkeModellSchlüsselparameterMatchCost
ABBS203-C253P, C25A, 6Die★★★★★Medium, reliable quality
Siemens5SY6325-7CC3P, C25A, 6Die★★★★★Medium, German quality
CHINTNXB-63-3P C253P, C25A, 6Die★★★★☆Lower, high-quality domestic
LeckerCDM30s-63C25/33003P, C25A, 6Die★★★★☆Lower, kostengünstig
Changshu-SchalterCH1-63C25/3P3P, C25A, 6Die★★★★☆Lower, well-known domestic brand
LiangxinNDM1-63C25/3P3P, C25A, 6Die★★★★☆Lower, suitable for industry

Key Selection Advice for Replacements

  1. Direct equivalent: Prefer IC65N 3P C25A (A9F18325) to match original protection characteristics
  2. Auslösekurve:

C-curve (5–10 Zoll): distribution & Beleuchtung

D-curve (10–14 Zoll): Motoren, transformers to avoid nuisance tripping

  1. Bruchkapazität:

6Die (N-type): general commercial & residential

10Die (H-type): industrial & large commercial

15Die (L-type): critical systems with high fault current

  1. Polen:

3P: 3-phase 3-wire (no neutral protection)

4P: 3-phase 4-wire (Phase + neutral protection)

  1. Brand choice:

International (ABB, Siemens): stable, for critical equipment & export projects

Inländisch (CHINT, Lecker): kostengünstig, for general industrial & civil projects

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen