Three-Phase Phase Sequence & Phase Loss Monitoring Relay The DPA51CM44 is a three‑phase power monitoring relay from the DPA51 series manufactured by Carlo Gavazzi, specifically designed to detect phase sequence errors and phase loss faults in three‑phase power supplies, protecting motors and other three‑phase equipment from damage. Model Code Explanation Part of Model Description DPA ...

  • Produktdetails

Three-Phase Phase Sequence & Phase Loss Monitoring Relay

The DPA51CM44 is a three‑phase power monitoring relay from the DPA51 series manufactured by Carlo Gavazzi, specifically designed to detect phase sequence errors and phase loss faults in three‑phase power supplies, protecting motors and other three‑phase equipment from damage.

  1. Model Code Explanation
Teil des ModellsBeschreibung
DPAProduct series (three‑phase monitoring relay)
51Produkttyp (phase sequence & phase loss monitoring)
CFunction type (standard version, monitors phase sequence and phase loss)
M44Supply and output specification (208–480 VAC, SPDT output)
  1. Key Technical Specifications
ParameterSpezifikation
FunktionThree‑phase phase sequence monitoring, phase loss monitoring
Supply Voltage208–480 VAC (±15%), self‑powered from the monitored supply
Messbereich177–550 VAC (phase‑to‑phase)
Frequenzbereich50/60 Hz (±5 %)
Output1 SPDT-Relais, 5 A / 250 VAC, energized in normal condition
Regenerative Voltage DetectionDetects regenerative voltage up to 85% of rated voltage
MontageDIN rail mounting (compliant with DIN/EN 50022)
Abmessungen17.5 × 81 × 67.2 mm (ultra‑slim design)
SchutzklasseIP20
Betriebstemperatur-25 °C bis +55 °C
Lagertemperatur-40 °C bis +85 °C
  1. Funktionsprinzip & Merkmale
  2. Funktionsprinzip

Monitors the phase relationship of the three‑phase supply. When all three phases are present and the phase sequence is correct, the relay remains energized. If phase loss or incorrect phase sequence occurs, the relay de‑energizes immediately to trigger protection.

  1. Main Features

True RMS measurement ensures accurate detection even under non‑sinusoidal conditions

Regenerative voltage detection enables phase loss detection even when motor is rotating

Kompakt 17.5 mm width saves control cabinet space

LED status indicator for quick fault diagnosis

No external power supply required; powered directly from the monitored three‑phase lines

  1. Anwendungen

Suitable for all types of equipment and systems requiring three‑phase power protection, einschließlich:

Motor control circuits (prevents reverse rotation and phase‑loss burnout)

Elevators and lifting equipment

Air conditioning and refrigeration systems

Pumps and fan systems

Industrial automation production lines

Any electrical equipment requiring three‑phase power monitoring

  1. Installation & Verdrahtung
  2. Installation

Mount on standard 35 mm DIN-Schiene

Ensure adequate ventilation; avoid installation near heat sources

  1. Verdrahtung

Connect L1, L2, L3 to the three‑phase power supply

Connect NO (Normalerweise geöffnet), NC (Normalerweise geschlossen), COM (Common) to the control circuit

  1. Ersatz & Extended Models
Ersatz / Extended ModelFunctional Difference
DPA51CM48208–480 VAC, 2 SPDT outputs
DPA51CM54480–690 VAC, 1 SPDT output
DPA51CM58480–690 VAC, 2 SPDT outputs
DPA71 SeriesSimilar to DPA51, 35.5 mm Breite, extended functions
Chinese Brand EquivalentsGOLDAIR DPA51 series, Shanghai Fuji Electric DPA51CM44, usw.
  1. Bestellinformationen
HerstellerCarlo Gavazzi
ModellDPA51CM44
Standard Pack1 Einheit / box

Operating Principle of DPA51CM44

The DPA51CM44 is a self‑powered three‑phase phase sequence & phase loss monitoring relay. Its core function is to continuously monitor voltages on L1/L2/L3, determine whether phase loss has occurred and whether phase sequence is correct, and output a protection signal via the internal relay.

  1. Power Supply Method

It does not require a separate external control power supply; it operates directly from the monitored three‑phase supply L1, L2, L3.

  1. Detection Logic

Internal circuitry continuously monitors between the three phases:

Presence of voltage (phase loss detection)

Correct 120° phase difference sequence (phase sequence detection)

  1. Betriebsmodi
  2. Normaler Zustand (all three phases present + correct phase sequence)

Internal detection circuit confirms normal condition → output relay energizes

→ NO contact closes, NC contact opens, equipment runs normally.

  1. Single‑phase or two‑phase loss

Voltage loss detected → relay immediately de‑energizes

→ control circuit is interrupted, providing protection.

  1. Reversed phase sequence (incorrect L1/L2/L3 order)

Abnormal phase relationship → relay de‑energizes

→ protection is triggered to prevent motor reverse rotation.

  1. Additional Features

True RMS measurement ensures accurate judgment under harmonic and non‑sinusoidal conditions.

Built‑in regenerative voltage detection identifies back EMF from motor inertia to avoid misoperation.

LED indicator: ON in normal condition, OFF in fault condition for on‑site troubleshooting.

The DPA51CM44 is a three‑phase phase sequence and phase loss protection relay suitable for 208-480 VAC. It can be used in any application using three‑phase AC power where reverse rotation or phase‑loss burnout must be avoided. Typical applications include:

  1. Motor Equipment (Am häufigsten)

Fans, Wasserpumpen, oil pumps, Umwälzpumpen

Air compressors, vacuum pumps, Kompressoren

Machine tool spindle motors, conveyor motors

Prevents winding burnout due to phase loss and motor reverse rotation caused by reversed phase sequence.

  1. HVAC & Refrigeration Equipment

Central air conditioning units, water chillers

Cooling tower fans, air‑source heat pumps

Industrial refrigeration units

Prevents damage to compressors and fans from reversed phase sequence.

  1. Heben & Lifting Equipment

Elevators, freight elevators, Hebebühnen

Cranes, winches, hoists

Reversed phase sequence causes immediate reverse operation, creating severe safety hazards, so monitoring is essential.

  1. Water Supply, Drainage & Brandschutzsysteme

Feuerlöschpumpen, sprinkler pumps, sewage pumps

Booster pumps, industrial circulation water systems

Ensures pumps do not reverse and shuts down promptly on phase loss.

  1. Automatisierte Produktionslinien & Equipment

Belt conveyors, roller lines, assembly lines

Verpackungsmaschinen, food machinery, Textilmaschinen

Injection molding machines, Extruder, die‑casting machines

Maintains stable three‑phase power and avoids unexpected line stoppages or damage.

  1. Construction & Power Distribution Projects

Temporary three‑phase power on construction sites

Power monitoring in distribution cabinets and power boxes

Power distribution circuits in shopping malls and factories

Quickly detects abnormal incoming three‑phase power to prevent collective failure of downstream equipment.

Almost all electromechanical equipment powered by approximately three‑phase 380 V that must not reverse or run under phase loss can use the DPA51CM44 for power protection.

Carlo Gavazzi DPA Series Three‑Phase Monitoring Relay Model List

The Carlo Gavazzi DPA series focuses on three‑phase phase sequence and phase loss monitoring, with some models offering extended functions. Below is a complete list sorted by sub‑series, including key parameters and feature descriptions.

  1. Modellbenennungskonvention
TeilBeschreibung
DPASeriencode (three‑phase phase sequence / phase loss monitoring)
XXSub‑series number (01, 51, 52, 55, 71, usw.)
CDFunction type (C = standard, D = special)
MXXSupply & output specification
M44 = 208–480 VAC, 1 SPDT
M48 = 208–480 VAC, 2 SPDT
M54 = 480–690 VAC, 1 SPDT
M58 = 480–690 VAC, 2 SPDT
M23 = 24 VDC, 1 SPDT
HVACSpecial version for A2L/A3 flammable refrigerant systems
  1. Complete Model List by Sub‑Series

2.1 DPA01 / PPA01 Series (wide voltage range, including plug‑in PPA01)

ModellSupply VoltageOutputMontageMerkmale
DPA01CM44208–480 VAC1 SPDTDIN railStandard, phase sequence + Phasenverlust
DPA01CM60208–600 VAC1 SPDTDIN railGroßer Spannungsbereich
DPA01CM69208–690 VAC1 SPDTDIN railUltra‑wide voltage range
DPA01DM2324 VDC1 SPDTDIN railDC supply version
DPA01DM48208–480 VAC2 SPDTDIN railDual output
PPA01CM44208–480 VAC1 SPDTPlug‑inStandard, plug‑in mounting
PPA01CM48208–480 VAC2 SPDTPlug‑inDual output
PPA01DM48208–480 VAC2 SPDTPlug‑inDual output special version

2.2 DPA51 / DPA71 Series (compact, 17.5 mm Breite)

ModellSupply VoltageOutputMontageMerkmale
DPA51CM44208–480 VAC1 SPDTDIN railStandard, ultra‑slim 17.5 mm
DPA51CM44HVAC208–480 VAC1 SPDTDIN railFor flammable refrigerant HVAC systems
DPA51CM48208–480 VAC2 SPDTDIN railDual output
DPA51CM54480–690 VAC1 SPDTDIN railHigh‑voltage version
DPA51CM58480–690 VAC2 SPDTDIN railHigh‑voltage dual output
DPA71CM44208–480 VAC1 SPDTDIN rail35.5 mm Breite, extended functions
DPA71CM48208–480 VAC2 SPDTDIN rail35.5 mm Breite, dual output

2.3 DPA52 Series (switching power supply, wide input range)

ModellSupply VoltageOutputMontageMerkmale
DPA52CM44125–624 VAC1 SPDTDIN railSwitching power supply, wide input
DPA52CM44HVAC125–624 VAC1 SPDTDIN railFor flammable refrigerant HVAC
DPA52CM48125–624 VAC2 SPDTDIN railDual output
DPA52CM54480–690 VAC1 SPDTDIN railHigh‑voltage version
DPA52CM58480–690 VAC2 SPDTDIN railHigh‑voltage dual output

2.4 DPA55 Series (with voltage monitoring)

ModellSupply VoltageOutputMontageMerkmale
DPA55CM44208–480 VAC1 SPDTDIN railPhase sequence + Phasenverlust + voltage monitoring (±10 % / ±15%)
DPA55CM48208–480 VAC2 SPDTDIN railDual output with voltage monitoring
DPA55CM54480–690 VAC1 SPDTDIN railHigh‑voltage with voltage monitoring
DPA55CM58480–690 VAC2 SPDTDIN railHigh‑voltage dual output with voltage monitoring

2.5 Other DPA Series Models

ModellSerieMerkmale
DPA03CM44DPA03Three‑phase phase sequence / Phasenverlust, extended functions
DPA03CM48DPA03Dual output, extended functions
DPA03CM69DPA03Ultra‑wide voltage range, extended functions
  1. Key Feature Comparison
SerieBreiteStromversorgungKernfunktionGeeignete Spannung
DPA5117.5 mmSelf‑powered (monitored supply)Phase sequence + Phasenverlust208–480 VAC
DPA7135.5 mmSelf‑powered (monitored supply)Phase sequence + Phasenverlust208–480 VAC
DPA0135.5 mmSelf‑powered (monitored supply)Phase sequence + Phasenverlust208–690 VAC
DPA5235.5 mmSwitching power supplyPhase sequence + Phasenverlust125–624 VAC
DPA5535.5 mmSelf‑powered (monitored supply)Phase sequence + Phasenverlust + voltage monitoring208–690 VAC
  1. Auswahlhilfe
  2. Space requirement: Choose DPA51 (17.5 mm) to save control cabinet space
  3. Spannungsbereich:

208-480 VAC: select models with suffix CM44 / CM48

480-690 VAC: select models with suffix CM54 / CM58

Ultra‑wide range: select CM60 / CM69 from DPA01 series

  1. Output requirement:

Single control loop: 1 SPDT (CM44 / CM54)

Dual control loops: 2 SPDT (CM48 / CM58)

  1. Special applications:

Flammable refrigerant HVAC systems: select models marked HVAC

Voltage monitoring required: select DPA55 series

Vorher: