Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

CHINT CJX2-3210 AC Contactor - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Schütz/

CHINT CJX2-3210 AC Contactor

CJX2-3210 is a 3-pole 32A AC contactor from CHINT CJX2 series, mit 3 NO main poles + 1 NO auxiliary contact. It is suitable for controlling 15kW motors at AC-3 380V. Coil voltages include 220V/380V and others. Direct replacement models include Schneider LC1N3210, Siemens 3RT6035-1AN20, usw. Model Explanation & Basic Positioning Model Part Meaning CJX2 ...

  • Produktdetails

CJX2-3210 is a 3-pole 32A AC-Schütz from CHINT CJX2 series, mit 3 NO main poles + 1 NO auxiliary contact.

It is suitable for controlling 15kW motors at AC-3 380V. Coil voltages include 220V/380V and others.

Direct replacement models include Schneider LC1N3210, Siemens 3RT6035-1AN20, usw.

  1. Model Explanation & Basic Positioning
ModellteilBedeutung
CJX2CHINT AC contactor series (equivalent to Schneider LC1‑D series)
32Rated operational current 32A (AC‑3 utilization category at 400V)
10Hilfskontakte: 1 NEIN + 0 NC

Produktpositionierung:

Industrial‑grade general‑purpose AC contactor, suitable for frequent starting and control of AC motors.

Can form a magnetic starter with thermal overload relays for motor protection.

  1. Wichtige technische Parameter
ArtikelSpezifikation
Rated operational voltageBis zu 690 V Wechselstrom (50/60Hz)
Rated operational current32A (AC‑3 400V), thermal current Ith = 50A
Controlled power15kW (AC‑3 380V), 21A (AC‑3 660V)
Hilfskontakt1 NEIN, rated 5A/220V AC
Coil voltageOptional: 220V/380V/110V/36V/24V AC
Insulation characteristicsUI = 660V, compliant with GB14048.4 / IEC60947‑4‑1
Mechanical / electrical life10 Millionen Mal / 1 Millionen Mal (AC‑3)
Abmessungen (L×W×H)83×58×101 mm
MontageStandard 35mm DIN rail
  1. Strukturelle Merkmale & Materials
  2. Silver alloy contacts: Excellent conductivity and arc resistance, ensuring reliable switching.
  3. 32‑sheet silicon steel core: Reduces hysteresis loss, smoother pull‑in, stable operation.
  4. Flame‑retardant housing: Meets V0 flame rating, improves safety.
  5. Clear side marking: Modell, Stromspannung, CCC-Zertifizierung, usw.
  6. Anwendungen
  7. Industrielle Automatisierung: Motor control, Fans, Pumps, Kompressoren.
  8. Building electrical: HVAC, fire pumps, exhaust fans.
  9. Agricultural machinery: Irrigation, feed processing equipment.
  10. Energiesysteme: Remote circuit control in distribution panels.
  11. Typical matching: Long‑running oil station motors, unidirectional equipment (no NC auxiliary required).
  12. Comparison Within CJX2 Series
ModellNennstromAux. KontakteAC‑3 380V PowerAbmessungen (mm)
CJX2‑09109A1 NEIN4kW73×47×82
CJX2‑181018A1 NEIN7.5kW73×47×82
CJX2‑251025A1 NEIN11kW83×58×96
CJX2‑321032A1 NEIN15kW83×58×101
CJX2‑401140A1 NEIN + 1 NC18.5kW128×79×116
CJX2‑651165A1 NEIN + 1 NC30kW128×79×116
  1. Cross‑Brand Replacements
MarkeErsatzmodellKompatibilität
SchneiderLC1N3210M7N / LC1R3210M5NSame dimensions & Parameter
Siemens3RT6035‑1AN20 (domestic type)Functionally equivalent, mounting compatible
ABBA145‑30‑11 (32A class)Aux. can be configured as 1 NEIN
LeckerCJX2‑3210Fully interchangeable
Changshu-SchalterCK3‑3210Same performance & Parameter
  1. Auswahl & Application Notes
  2. Coil voltage: Selected per control circuit (commonly 220V / 380V).
  3. Load matching: 32A ≈ 15kW at AC‑3 380V; avoid overload.
  4. Aux. contact expansion: F4‑11 or similar modules can be added.
  5. Protection coordination: Used with NR2 series thermal relays (z.B. NR2‑36) for overload protection.
  6. Umfeld: Operating temperature ‑5°C ~ +40°C; avoid dust & ätzendes Gas.

Packing: 4 pcs/box, 32 pcs/carton

Comparison of CHINT Contactor Series

Overview:

CHINT contactors are divided into:

Classic (CJX2/CJ20/CJX8), Upgraded (NXC/NC5), High‑Power (NC8), DC Special (CJZ8/NCZ5).

NXC fully replaces CJX2 with better performance; NC5 focuses on intelligence & modularity; NC8 covers ultra‑high current; CJZ8 is for DC control.

Priority: NXC / NC5; use special series for special applications.

  1. Series Positioning & Ersatz
SeriePositionierungReplaced By / ReplacesHauptmerkmale
CJX2Classic generalFully replaced by NXCCost‑effective, simple structure, flexible aux. Kontakte
NXCNew generationReplaces CJX2, upgradedHigh efficiency, long life, standard 1NO+1NC, strong modularity
NC5Smart & premiumHigh‑end marketWide temp ‑25°C~+55°C, Kommunikation, complex automation
NC8High‑power heavy‑dutyIndependent, up to 1000AUp to 1000A AC‑3 415V, for large motors & heavy industry
CJX8Traditional heavy‑dutyPartially replaced by NC8Direct‑operated double break, suitable for legacy retrofits
CJ20Traditional generalReplaced by NXC/NC5Mature structure, low cost, civil & light industry
NXC‑XMGSpecial loadIndependentFor fans & Pumps, high energy saving
CJZ8/NCZ5DC dedicatedIndependentEnhanced arc extinguishing, new energy & energy storage
  1. Wichtige technische Parameter

2.1 Basic Electrical Data

SerieAktueller BereichNennspannungAC‑3 380V PowerStandard Aux. Kontakte
CJX29A~95AUp to 690V0.75kW~45kWBelow 32A: 1NO/1NC; ≥40A:1NO+1NC
NXC6A~630AUp to 690V0.37kW~315kWVolles Sortiment: 1NO+1NC
NC56A~630AUp to 690V0.37kW~315kW1NO+1NC, expandable to 6NO+6NC
NC86A~1000AUp to 690V0.37kW~500kW2NO+2NC, expandable to 6NO+6NC
CJX89A~250AUp to 660V4kW~110kW3NO+1NO/1NC or 4NO
CJ2010A~630AUp to 660V5.5kW~315kW1NO+1NC

2.2 Life & Umfeld

SerieMechanisches LebenElektrisches Leben (AC‑3)Operating TempMontage
CJX210 million1 million‑5°C~+40°C35mm DIN / screw
NXC12 million1.2 million‑25°C~+55°C35mm DIN / screw
NC515 million1.5 million‑25°C~+55°C35mm DIN / screw
NC810 million0.8 million (high current)‑25°C~+55°CMainly screw
CJ208 million0.8 million‑5°C~+40°CScrew
  1. Struktur & Functional Differences

3.1 CJX2 (Classic)

Struktur: Direct‑operated single break, modular; F4 aux., F5 timer, NCF1 side aux. available.

Kontakte: Silver alloy, 3P main, flexible aux. (10/01/11).

Spule: AC/DC, 24V~380V.

3.2 NXC (Upgraded)

Optimized magnetic system, coil power ≈ 30% lower than CJX2.

Improved silver alloy contacts, better arc extinguishing.

Standard 1NO+1NC; supports aux., timer, mechanical interlock.

3.3 NC5 (Smart Premium)

Optional communication module (Modbus, usw.) for IIoT.

Wide temperature, suitable for outdoor & harsh environments.

Enhanced insulation & short‑circuit withstand.

3.4 NC8 (High‑Power)

Enhanced arc chamber for high‑current breaking up to 1000A.

Optimized heat dissipation for heavy‑duty continuous operation.

Heavy‑duty mechanical structure, high vibration resistance.

3.5 CJX8 (Traditional Heavy‑Duty)

Direct‑operated double break; front‑connected or rear‑connected versions.

Bis zu 4 Stangen (3 hauptsächlich + 1 aux or 4 hauptsächlich) for special applications.

3.6 DC Contactors

CJZ8: Low‑voltage DC (12V~220V), up to 40A, small DC loads.

NCZ5: High‑voltage DC (up to 1500V), up to 500A, new energy vehicles & energy storage.

Dedicated DC arc extinguishing structure.

  1. Anwendungsszenarien
SerieBest ForTypische BelastungNicht empfohlen
CJX2Legacy retrofit, budget projectsSmall motors ≤15kW, Beleuchtung, HeizungHigh‑end automation, harsh environments
NXCIndustrielle Automatisierung, new projectsMedium motors ≤315kW, Fans, PumpsUltra‑large motors, special DC loads
NC5Smart factories, complex systems, im FreienMedium & large motors, production linesCost‑sensitive simple circuits
NC8Large industry, Leistung, metallurgyLarge motors ≤500kW, TransformatorenSmall loads, zivile Gebäude
CJX8Legacy maintenance, special controlTraditional machinery, special circuitsNew smart projects
CJ20Civil, light industry, temporary powerAC units, Pumps, small machinesFrequent switching, high‑end automation
DC seriesNew energy, energy storage, railDC motors, batteries, LadegeräteAC loads
  1. Auswahlhilfe & Replacements

5.1 Selection Priority

  1. New projects: NXC (replaces CJX2)
  2. Smart/complex systems: NC5
  3. Ultra‑high power >315kW: NC8
  4. DC loads: CJZ8 / NCZ5
  5. Legacy retrofit: CJX2/CJ20/CJX8 or upgrade to NXC/NC5

5.2 Cross‑Series Replacement

OriginalEmpfohlener ErsatzVorteil
CJX2‑09~95NXC‑06~100Standard 1NO+1NC, life +20%, power ‑30%
CJ20‑10~630NXC‑12~630 / NC8‑12~1000Better performance, modular, easier maintenance
CJX8‑09~250NC8‑06~250Better arc extinguishing, wide temperature

5.3 Model Selection Tips

Aktuell: 32A ≈ 15kW; 63A ≈ 30kW; 100A ≈ 45kW at AC‑3 380V.

Aux. Kontakte: NXC has 1NO+1NC standard; CJX2 uses 10/01/11.

Spule: 220V/380V/110V/36V/24V AC/DC.

Montage: 35mm DIN preferred; screw for high power.

  1. Special Notes: CHINT CJX2‑3210

As a representative model of CJX2 series, CJX2‑3210 is a 3‑pole 32A AC contactor with 3 NO main contacts + 1 NO auxiliary contact, suitable for 15kW motor control at AC‑3 380V.

Common replacements:

CHINT NXC‑3210 (upgraded)

Schneider LC1N3210M7N

Siemens 3RT6035‑1AN20

ABB A145‑30‑11 (32A class)

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen