Delta VFD055C43A-21-5.5kW Vector Control Inverter - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Delta VFD055C43A-21-5.5kW Vector Control Inverter - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Solarwechselrichter/elektrisch/

Delta VFD055C43A-21-5.5kW Vector Control Inverter

MarkeModellSerie
Siemens6SL3210-1KE21-3UF1 (G120C PN)SINAMICS G120C
MitsubishiFR-A840-00720-2-60FREQROL A840
YaskawaCIMR-AB4A0018FBAA1000
SchneiderATV320U75N4Altivar 320
ABBACS550-01-012A-4ACS550

  • Produktdetails

 

ModellteilBedeutungAusführliche Erklärung
VFDDelta Inverter IdentifierAbbreviation for Variable Frequency Drive, the universal prefix for Delta’s industrial automation inverters.
55Anwendbare MotorleistungFor 5.5kW (7.5HP) Motoren; this is the rated output power of the drive.
CSeriencodeC2000/C2000+ Series – Delta high-performance general-purpose vector inverter, supporting induction motors and permanent magnet synchronous motors.
43Spannungsklasse & Phase4 = 3-phase 400V class (380~480V); 3 = 3-phase input (vs. 1 für einphasig).
ASteuermodus & MerkmaleSupports Vector Control (FOC), Drehmomentkontrolle (TRQ), high-performance algorithm, 200% starting torque at 0.5Hz.
-21Version & KonfigurationStandardversion: built-in braking unit (selected power ratings), no built-in EMC filter (external available), compliant with international standards.
  1. Grundlegende technische Spezifikationen (Official 2026 Data)
KategorieArtikelWertNotizen
Grundlegende SpezifikationenNennleistung5.5kW (7.5HP)For 5.5kW 3-phase induction motors
Eingangsspannung3-Phase 380~480V (+10%/-20%)47~63Hz, großer Spannungsbereich
Nennausgangsstrom12A (Schwerlastbetrieb) / 10.8A (light duty)Continuous operation in heavy-duty mode
Output Frequency Range0.1~600HzFor both low‑ and high‑speed applications
Kontrollieren Sie die LeistungSteuermodusSensorless Vector, Closed-loop Vector, V/F-SteuerungSwitchable closed/open loop
Anlaufdrehmoment200% Nenndrehmoment bei 0,5 HzIdeal for heavy starting loads
Überlastfähigkeit150% for 60s; 200% for 3sFor shock loads
Speed Accuracy±0,5 % (open-loop) / ±0.02% (closed-loop)High precision speed control
Torque Response Time≤10msSchnelle dynamische Reaktion
HardwareSchutzgradIP20 (cabinet mount)Fingersicher; clean environment recommended
KühlungForced air (removable fan)Einfache Wartung, lange lebensdauer
Integrierte FunktionenBremseinheit (≤7.5kW), SPS (5,000 Schritte)High integration, fewer external parts
KommunikationRS-485 (Modbus RTU) StandardPROFINET/EtherNet/IP/CANopen optional
UmfeldBetriebstemp-10~40°C (derate 40~50°C)Derate 1% per °C above 40°C
Lagertemp-20~60°CFeuchtigkeit vermeiden & ätzendes Gas
Luftfeuchtigkeit5~95 % (nicht kondensierend)Suitable for industrial environments

III. Kernfunktionen & Vorteile

3.1 High‑Performance Control

Vektorsteuerung: Precise independent torque & speed control for complex loads.

Integrierte SPS: 5,000-step logic programming for simple automation, reducing external PLC dependency.

Auto energy saving: Dynamically adjusts output voltage; saves 20~50% at light load.

Motor auto-tuning: Completes matching in <10S, simplifies commissioning.

3.2 Hochzuverlässiges Design

Modularer Aufbau: Hot-swappable keypad, expandable I/O and communication cards for easy maintenance.

Voller Schutz: Überstrom, Überspannung, Unterspannung, überhitzen, Überlast, Phasenverlust, Erdschluss, usw.

Safe stop: Supports STO (Sicher abgeschaltetes Drehmoment), SIL 2 zertifiziert.

Wide grid tolerance: Withstands ±15% voltage fluctuation for harsh grids.

3.3 Flexible Kommunikation & Erweiterung

Standard RS-485 Modbus RTU for multi-drive network control.

Optional modules: PROFINET, EtherNet/IP, PROFIBUS DP, CANopen.

Compatible with Siemens, Mitsubishi, Rockwell PLCs via standard telegrams and process objects.

Fernüberwachung & diagnostics via Delta DIAStudio or TIA Portal.

  1. Anwendungen & Auswahltipps

4.1 Empfohlene Anwendungen

IndustrieTypische AnwendungenMerkmale
Allgemeine MaschinenPumps, Fans, Kompressoren, MischerEnergieeinsparung, stabiler Betrieb, longer equipment life
MaterialhandhabungFörderer, Kräne, Hebezeuge, VerpackungsmaschinenHigh precision speed control, heavy start, quick stop
Metal ProcessingLathes, milling, grinding, punching machinesHigh response, präzise positionierung, Drehmomentregelung
Textile & DyeingTextile machines, dyeing machines, stenter framesConstant tension, Synchronbetrieb, wide speed range
Plastik & RubberInjection molding, extrusion, blow moldingSignificant energy saving (20~60 %), stable pressure control

4.2 Wichtige Auswahlpunkte

  1. Power matching: Use VFD055C43A-21 for 5.5kW motors; avoid undersizing.
  2. Ladetyp:

Constant torque (Förderer, Mischer): use heavy-duty mode (12A).

Variable torque (Fans, Pumps): light-duty mode (10.8A) for better efficiency.

  1. Control requirements:

Hochpräzise Positionierung: use encoder (PG card) Vektor mit geschlossenem Regelkreis.

Network control: add communication module (z.B., PROFINET).

  1. Umfeld:

Hohe Temperatur: extra cooling or derating required.

Dusty environment: dust cover + regular fan cleaning.

  1. Ersatzmodelle & Upgrade-Pfad

5.3 Upgrade-Vorschläge

  1. Basic upgrade: VFD‑M/GD10 → C2000+ for better precision & Funktionen.
  2. Communication upgrade: Add PROFINET card for Industry 4.0 connectivity.
  3. System upgrade: Combine with Delta PLC (DVP series) & HMI for full automation solution.

Buying Notes

  1. Confirm suffix -21 (Standardversion), avoid old versions (z.B., -00).
  2. Verify power & aktuell: 5.5kW → 12A rated.
  3. Buy from authorized Delta channels for genuine product & Service.
  4. Order accessories as needed: communication card, Tastenfeld, braking resistor.

VII. Installation & Wartung

7.1 Installationsregeln

  1. Montage: Wall/cabinet mount, vertical installation; ≥150mm clearance top & bottom for ventilation.
  2. Verdrahtung:

Separate power & control cables to avoid interference.

Shielded cable for signals, einseitige Erdung.

Braking resistor matched to power (≤7.5kW internal; external ≈100Ω/500W).

  1. Erdung: Ground resistance ≤4Ω for safety & noise immunity.

Delta VFD055C43A-21 is a high‑performance 5.5kW vector inverter from the C2000+ series, featuring high precision, Zuverlässigkeit, and expandability for diverse industrial applications. With built-in PLC, wide voltage tolerance, and complete protection, it is an excellent choice for general industrial drive solutions. Select based on motor power, load type, Kontrollanforderungen, and environment for optimal performance and cost-effectiveness.

Complete Replacement Guide for Delta VFD055C43A-21

  1. Delta Internal Replacements (C2000+-Serie, Seamless Compatibility)

1.1 Direct Same‑Series Replacements

FehlercodeUrsacheLösung
OCÜberstromCheck motor short, Überlast, acceleration time
OVÜberspannungCheck mains voltage, deceleration time, braking resistor
UVUnterspannungCheck input phase, Stromspannung, cable size
OHÜberhitzenCheck fan, Belüftung, Umgebungstemperatur
PHPhasenverlustCheck input/output wiring, motor winding

1.2 Near‑Power Replacements

ModellLeistungNennstromHauptmerkmaleAnwendung
VFD055C43A-21 (Original)5.5kW12A / 10.8AC2000+, vector, built-in brake, RS-485Allgemeine Industrie
VFD055C43A-21 (Aktualisiert)5.5kW12ABetter cooling, 10,000-step PLC, more protocolsNeue Projekte
VFD055CH43A-215.5kW12ACH2000, fan/pump specializedFans, Pumps
VFD055CP43B-215.5kW12ACP2000, hoist/crane dedicatedKräne, Hebezeuge
  1. Global Brand Replacements (5.5kW / 400V Vector)

2.1 Premium Brands

MarkeModellSerieKontrolleVorteil
Siemens6SL3210-1KE21-3UF1 (G120C PN)SINAMICS G120CVector/V/FPROFINET, EMC filter
MitsubishiFR-A840-00720-2-60FREQROL A840VektorHigh response, integrierte SPS
YaskawaCIMR-AB4A0018FBAA1000VektorGeräuscharm, stabil
SchneiderATV320U75N4Altivar 320Vector/V/FKompakt, multi-protocol
ABBACS550-01-012A-4ACS550DTCHigh torque accuracy

2.2 Cost‑Effective Brands

MarkeModellSerieKontrolleVorteil
InnovationMD280NT5.5GBMD280VektorPROFINET supported
VeichiAC70-T3-055GAC70VektorFull-featured, niedrige Kosten
INVTCHF100A-5R5G/7R5P-4CHF100AVektorBuilt-in brake un

III. Critical Replacement Rules (Must Follow)

  1. Leistung & aktuell: Rated power ≥5.5kW, current ≥12A (Schwerlastbetrieb).
  2. Stromspannung: 400V-Klasse (380~480V) only; do NOT use 200V directly.
  3. Kontrolle: Prefer vector control for matching dynamics.
  4. Überlast: At least 150% for 60s.
  5. Kommunikation: RS-485 standard; PROFINET/EtherNet/IP optional.

Mechanical Compatibility

Abmessungen: ~90×180×150mm – use same or smaller size.

Kühlung: Forced air – keep airflow direction.

Brake unit: Internal for ≤7.5kW; match external if needed.

Tastenfeld: Use Delta standard keypad or compatible.

Best Replacement by Application

Allgemeine Maschinen: VFD055C43A-21 upgraded or Siemens G120C PN.

Fans & Pumps: VFD055CH43A-21 or Schneider ATV320U75N4.

Cranes/hoists: VFD055CP43B-21 or Mitsubishi FR-A840.

Budgetprojekte: Inovance MD280NT5.5GB or Veichi AC70-T3-055G.

  1. Upgrade Paths

4.1 Delta Internal Upgrade

  1. C2000 → C2000+ (Leistung & function improvement).
  2. Add PROFINET module (VFD-CM-PN01) for industrial networking.
  3. Pair with Delta PLC + HMI for full automation system.

4.2 Cross‑Brand Upgrade

  1. Kommunikation: RS-485 → PROFINET / EtherNet/IP.
  2. Kontrolle: Open-loop vector → closed-loop vector with encoder.
  3. Sicherheit: Choose models with STO (SIL 2).

The Delta VFD055C43A-21 has a wide range of replacements.

Same‑brand (C2000+ upgraded) offers seamless compatibility.

Cross‑brand (Siemens G120C PN, Mitsubishi FR-A840) provides higher performance.

Always follow core parameter matching to ensure stable, reliable replacement without performance loss or equipment damage.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen